Mon Sep 27 15:39:33 2010, Thomas Bergauer, common, PI-XY Table, , , ,
|
M-521.dd: (links/rechts)
downstream rechts => pos. limit [0]
downstream links => neg. limit [207]
----------------------
M-511.dd: (oben/unten)
oben [102]
unten [0]
----------------------
M-060.dg: (rotation)
parallel beam [7,5]
-------------------------------------------
Remote Control:
lokal ssh tunnel starten:
ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch
danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959).
|
Mon Sep 27 15:41:28 2010, Thomas Bergauer, common, Szintillatoren, , , ,
|
1: breit (1)
2: schmal (2)
3: breit (4)
4: schmal (8)
AND aus beiden breiten: 5
AND aus beiden schmalen: 10
|
Mon Sep 27 15:42:09 2010, Thomas Bergauer, common, TLU: wir stecken auf DUT 3, , , ,
|
TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin
TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1 abgeschnittenes Dummykabel
2 EUDRB hinten
4 EUDRB vorne
8 DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1 4 mm (front)
2 4 mm (front)
4 9 mm (back)
8 9 mm (back) |
Mon Sep 27 18:54:47 2010, Thomas Bergauer, BELLE, XY Position, , , ,
|
center position: 55/40/277,5 |
Tue Sep 28 16:50:31 2010, Thomas Bergauer, common, serial connection chiller, , , ,
|
Der chiller braucht ein gekreuztes serielles Kabel!! |
Wed Sep 29 16:28:17 2010, Thomas Bergauer, common, EUDET telescope pedestal run, 20089, 122850 (events built), 29.09.2010 16:27, 29.09.2010 17:33
|
EUDAQ config eudet2-test-6boards-in-2crates
rate: ~745.5 Hz
|
Wed Sep 29 17:38:15 2010, Thomas Bergauer, common, EUDET telescope pedestal run, 20097, 118125, 29.09.2010 17:37, 29.09.2010 18:09
|
new pedestal run of EUDET telescope with new JTAG settings of plane 3 (sensor 11) [according to Ingrid]:
VRef2 98
VRef1A 87
VRef1B 143
VRef1C 108
VRef1D 153
|
Wed Sep 29 18:53:05 2010, Thomas Bergauer, Micron Baby, XY Positions, , , ,
|
center position: 113/47/7.5
top left (direction jura): 121/53.5/7.5
bottom right (direction saleve): 105/40.5/7.5 |
Thu Sep 30 14:45:16 2010, Thomas Bergauer, Micron Baby, run, run015, 22.5k, 30.09.2010 13:18:11, 30.09.2010 14:38:01
|
micron baby stack angle scan 15 grad mit 3 modulen
HV=100V, I=3.8uA
Beam on
telescope position: 129/76/187.5
telescope run 20109 |
Thu Sep 30 23:09:29 2010, Thomas Bergauer, Micron Baby, run, run019, 162000, 30.09.2010 23:08:03, 01.10.2010 9:33:38
|
micron baby: 4 DUTs
HV=100V I=12uA I_stop=15.4uA
Beam on
45° rotation
telescope run 20115 (after JTAG programming of telescope chips due to config errors)
|
Fri Oct 1 23:50:28 2010, Thomas Bergauer, CNM, run, run023, 2275, 01.10.2010 23:49:29, 01.10.2010 23:53:12
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
too much optimized alignment (XY-table to 133/74/187.5) ;-)
telescope run 20119 |
Fri Oct 1 23:55:12 2010, Thomas Bergauer, CNM, run, run024, 320k, 01.10.2010 23:53:12, 02.10.2010 09:47:37
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
optimized alignment (XY-table to 133/76/187.5)
telescope run 20120 |
Sat Oct 2 09:57:20 2010, Thomas Bergauer, CNM, run, run025, 150k, 02.10.2010 09:54:28, 02.10.2010 14:21:20
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
new position along the CNM strips (XY-table to 143/76/187.5)
telescope run 20122
|
Sat Oct 2 17:27:14 2010, Thomas Bergauer, ITE, cal, cal007, 83800, 02.10.2010 17:11:18 ,
|
ITE: 2 DUTs
2 x SILC + 2 x ITE
HV=100V
Beam on
one short only per sensor |
Wed Oct 6 11:51:25 2010, Thomas Bergauer, Micron Baby, run, run049, 4489, 06.10.2010 11:38:21, 06.10.2010 11:49:23
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=141uA (start of run)
beam on
not yet optimized XY-table positions (111/43.5/7.5) |
Sat Oct 9 12:25:36 2010, Thomas Bergauer, BELLE, run, run057, 276475, 09.10.2010 12:22:21, 09.10.2010 15:08:46
|
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73 degree
HV=100V / 36 uA (beginning), 35uA (end of run)
cooling: chiller set to 15C
PROBLEM: wrong config file (single hit, not multi6)
telescope run 20200
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...
|
|
Sat Oct 9 18:56:35 2010, Thomas Bergauer, common, path to telescope data, , , ,
|
eudetmac001.cern.ch
path is /Volumes/Data/eudet/Data/cern_2010_sept_silc_apvdaq (Vienna system)
and /Volumes/Data/eudet/Data/cern_2010_sept_silc_alibava (Santander system) |
Sun Oct 10 15:45:04 2010, Thomas Bergauer, common, end of success, , , 09.10.2010 19:44:23, NaN
|
;-)
genau das gleiche wollte ich auch gerade schreiben! |
Wed May 4 15:14:31 2011, Thomas Bergauer, Pt, info about module, , , ,
|
pt-Modul hat jeweils zwei OB1 Sensoren von STM (mit 122um Pitch)
im Abstand von 2mm uebereinander |
Tue Sep 28 01:13:57 2010, Markus Friedl, BELLE, cal, cal001, 83800, 28.09.2010 01:11:20,
|
first intcal with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled |
Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33
|
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled
position:centered in both axes 55 / 30 / 277.5
telescope: run20076 (in zero suppressed mode) |
Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,
|
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC |
Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14
|
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5
corresponds to telescope run 20078 |
Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31
|
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079 |
Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12
|
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
telescope run: 20080 |
Tue Sep 28 22:07:16 2010, Markus Friedl, BELLE, cal, cal002 DO NOT USE -> go to cal003, 83800, 28.09.2010 22:01:55,
|
Belle stack (Origami, Micron, Micron, Origami)
now cooling only for Origami, Micron are uncooled
chiller set point: -25°C, measured values on Origami: -10°C
HV=100V, Ibias=38µA, beam off
modified I2C settings for cold modules
temperature monitoring: Origami2 pipes in<->out swapped (to achieve shorter tubes)
PROBLEM: Origami n channels are swapped -> USE cal003 INSTEAD!!! |
Tue Sep 28 22:09:39 2010, Markus Friedl, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in
channel 2: Origami_mod1_out
channel 3: Origami_mod2_out (swapped with 4) - label not changed
channel 4: Origami_mod2_in (swapped with 3) - label not changed
channel 5: Micron_wedge_mod1_p
channel 6: Micron_wedge_mod1_n
channel 7: Micron_wedge_mod2_p
channel 8: Micron_wedge_mod2_n
The cooling pipes of the two Origami modules are connected in series, respectively. |
Tue Sep 28 23:23:47 2010, Markus Friedl, BELLE, run, run006, 2003, 28.09.2010 23:13:22, 28.09.2010 23:22:26
|
channels swapped -> stopped |
Tue Sep 28 23:24:35 2010, Markus Friedl, BELLE, run, run007, 1460, 28.09.2010 23:23:29, 28.09.2010 23:27:54
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20082
sensor config bug (only relevant for sensor display) found -> stopped |
Tue Sep 28 23:29:50 2010, Markus Friedl, BELLE, run, run008, 140000, 28.09.2010 23:29:01, 29.09.2010 09:36:58
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20083 |
Wed Sep 29 09:39:33 2010, Markus Friedl, BELLE, cal, cal003, 83800, 29.09.2010 09:38:00,
|
same as cal002, but now with corrected readout order |
Wed Sep 29 10:30:59 2010, Markus Friedl, BELLE, run, run009, 30000, 29.09.2010 10:27:27, 29.09.2010 11:06:35
|
zero suppressed (HIT4) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT4
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20084 |
Wed Sep 29 11:09:10 2010, Markus Friedl, BELLE, run, run010, 30000, 29.09.2010 11:08:03, 29.09.2010 11:50:07
|
zero suppressed (HIT5) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT5
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20085 |
Wed Sep 29 14:03:55 2010, Markus Friedl, BELLE, cal, cal004, 83800, 29.09.2010 14:02:25, 29.09.2010 14:45:05
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=100µA, beam off
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered |
Wed Sep 29 17:38:19 2010, Markus Friedl, Micron Baby, cal, cal005, 83800, 29.09.2010 17:36:38,
|
micron baby stack
HV=100V I=6.5uA
Beam off |
Wed Sep 29 19:01:28 2010, Markus Friedl, Micron Baby, run, run012, 2248, 29.09.2010 18:59:09, 29.09.2010 19:07:02
|
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/55/7.5
telescope run 20105 |
Wed Sep 29 19:08:56 2010, Markus Friedl, Micron Baby, run, run013, 89853, 29.09.2010 19:09:57, 30.09.2010 00:52:39
|
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/53.5/7.5 (shifted in height by -1.5mm wrt run012 for better DUT centering)
telescope run 20107 |
Thu Sep 30 00:56:32 2010, Markus Friedl, Micron Baby, run, run014, 100k, 30.09.2010 00:55:30, 30.09.2010 11:20:02
|
micron baby stack
HV=100V I=11.0uA
I_end = 16uA
Beam on
telescope position: 105/40.5/7.5
telescope run 20108 |
Thu Sep 30 15:06:28 2010, Markus Friedl, Micron Baby, cal, cal006, 83800, 30.09.2010 15:01:56,
|
micron baby: 4 DUTs - angle scan
HV=100V I=6.8uA
Beam off (turned on at ~8k events)
|
Thu Sep 30 15:39:53 2010, Markus Friedl, Micron Baby, run, run016, 31k, 30.09.2010 15:38:26, 30.09.2010 17:44:36
|
micron baby: 4 DUTs
HV=100V I=10.3uA (start of run); I=16.2uA (end of run)
Beam on
reference run @ 0°
telescope run 20110 |
Thu Sep 30 18:12:53 2010, Markus Friedl, Micron Baby, run, run017, 35000, 30.09.2010 18:11:53, 30.09.2010 20:22:43
|
micron baby: 4 DUTs
HV=100V I=13.5uA, I_stop=17uA
Beam on
15° rotation
telescope run 20111 |
Thu Sep 30 20:47:01 2010, Markus Friedl, Micron Baby, run, run018, 26938, 30.09.2010 20:45:48, 30.09.2010 22:25:25
|
micron baby: 4 DUTs
HV=100V I=13.7uA, I_stop=15.6uA
Beam on
30° rotation
telescope run 20112 |
Fri Oct 1 23:18:34 2010, Markus Friedl, CNM, run, run022, 8139, 01.10.2010 23:17:02 , 01.10.2010 23:45:51
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
not optimized alignment
telescope run 20118 |
Sat Oct 2 17:24:12 2010, Markus Friedl, ITE, run, run026, 5834, 02.10.2010 17:23:46 , 02.10.2010 17:31:51
|
2 x SILC + 2 x ITE
HV=100V
trying to find beam
telescope run 20124 |
Sat Oct 2 17:35:51 2010, Markus Friedl, ITE, run, run027, 2999, 02.10.2010 17:34:51 , 02.10.2010 17:38:39
|
2 x SILC + 2 x ITE
HV=100V
telescope position: 107
telescope run 20125
beam not found yet |
Sat Oct 2 18:36:57 2010, Markus Friedl, ITE, run, run028, 162263, 02.10.2010 18:34:06, 03.10.2010 08:11:13
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 119
short break ~2.10.2010 20:00 (beam off for a couple of minutes for access by marcos)
telescope run 20126 |
Sun Oct 3 08:14:39 2010, Markus Friedl, ITE, cal, cal008, 83800, 03.10.2010 08:13:06,
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 119
no beam (technical problem) |
Sun Oct 3 08:19:13 2010, Markus Friedl, ITE, run, run029, 75000, 03.10.2010 08:33:28, 03.10.2010 10:50:27
|
same as previous run
telescope run 20127
Configuration file for DAQ: cern10_ite_silc_single.cfg --> peak mode with 1 sample! |
Wed Oct 6 11:59:29 2010, Markus Friedl, Micron Baby, run, run050, 90000, 06.10.2010 11:57:55, 06.10.2010 15:30:37
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=141uA (start of run)
beam on
telescope position 118 / 41.1 / 7.5
no telescope run |
Wed Oct 6 16:33:55 2010, Markus Friedl, Micron Baby, run, run051, 90000, 06.10.2010 16:32:03, 06.10.2010 20:59:58
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=209uA (start of run, still rising); 203uA (end of run)
beam on, NIM trigger from TLU (no handshake)
telescope position 131 / 53.5 / 7.5
no telescope run - being tuned (some intervals during data taking are possible)
|
Wed Oct 6 23:48:49 2010, Markus Friedl, BELLE, run, run052, 165789, 06.10.2010 23:47:12, 07.10.2010 08:43:42
|
Belle stack without Origami2
HV=80V I=217uA
telescope setting 103 / 30 / 277.5
telescope run 20184
temperature of chiller set to 15°C
beam stopped at 7.10. 08:00 sharp, no beam until 8.10 - 8:00 according to SPS Page 1. We keep DAQ and telescope running and cross our fingers for at least some spills of particles.
Irradiated micron module 2, n-side: excessive hit count on channels at the edges of the APV chips - no such thing on the p-side |
Fri Oct 8 17:26:36 2010, Markus Friedl, BELLE, cal, cal015, 83800, 08.10.2010 17:22:44,
|
Belle stack without Origami2
HV=11V I=32uA
beam on
2 suspicious APVs on n side of Micron due to burnt strip
trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |
Fri Oct 8 18:12:43 2010, Markus Friedl, BELLE, run, run054, 90000, 08.10.2010 18:08:48, 08.10.2010 21:49:36
|
Belle stack w/o Origami2 after irradiation
HV=80V I=224uA (beginning of run)
2 suspicious APVs on Micron n side
xy-table position 7 / 30 / 277.5 (shoots at the smaller edge of the trapezoidal sensor)
telescope run 20195 |
Fri Oct 8 23:05:03 2010, Markus Friedl, BELLE, cal, cal016, 83800, 08.10.2010 23:03:16,
|
Belle stack w/o Origami2 after irradiation
HV=80V / 258 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
Bias connection of Origami repaired --> lower noise on p-side |
Sat Oct 9 00:17:02 2010, Markus Friedl, BELLE, run, run056, 225k, 09.10.2010 00:15:53, 09.10.2010 09:54:28
|
Belle stack w/o Origami2 after irradiation
HV=80V / I_start=255 µA, I_stop=243 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron (possibly due to burnt strip)
same position as in previous run
telescope run 20198 - now with correct telescope threshold settings
a lot of "Error detected in APV 21, subevent 2. Event discarded, reset sent." errors started at 09.10.2010 09:00:25 (after whole night without any error) |
Sat Oct 9 15:29:09 2010, Markus Friedl, BELLE, run, run058, 30000, 09.10.2010 15:26:50, 09.10.2010 16:21:37
|
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73 - now with multi6 (previous run was single)
HV=100V / 35uA (beginning of run) 34uA (end of run)
cooling: chiller set to 15C
telescope run 20201
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem...
|
|
Sat Oct 9 19:44:36 2010, Markus Friedl, common, end of success, , , 09.10.2010 19:44:23, NaN
|
|
Wed Sep 15 10:25:13 2010, Marko Dragicevic, common, Equipment List, , , ,
|
Slow Control:
3x Source Measurement Unit Keithley K2410
-- Inv.Nr.: 540-702, 1000EUR
-- Inv.Nr.: 540-730, 1000EUR
-- Inv.Nr.: 540-709, 1000EUR
-- Koax-Kabel + Adapter auf Banane
Scanning Voltmeter Keithley K2700 , Inv.Nr.: 540-698, 1000EUR
-- Shunt-Widerstand-Platine
-- Flachbandkabel fuer Verbindung Shunt-Platine<->K2700
TRHX
-- 3 Sensoren
-- 2 lange Flachbandkabel, 1 serielles Kabel
LV-Power-Supplies, je 150EUR
-- GW Instek GPC-1850, SN.: 4080392
-- GW Instek GPC-1850D, Inv.Nr.: 545-059
-- GW Instek GPC-1850D, Inv.Nr.: 545-062
-- Systron Donner HR 20-10A, SN.: 781-092
-- Systron Donner HR 20-10A, SN.: 781-096
-- GW Instek GPS-3030D SN.: E871711
-- HAMEG MHP4030 SN.: 057910044 500EUR
Oszilloskop Tektronix TDS 3054, SN.: B011109, 2500EUR
-- 3 probes
Die Katze (Belle-HV-Supply)
-- 2x HV-Kabel 30m (rot/schwarz)
GBIP
USB Adapter NI GPIB-USB-HS, S/N 14693EB, 100EUR
-Kabel, 3x lang, 1x kurz
USB Temperaturlogger PicoTech TC-08, S/N.: VSR 08/519 100EUR
BELLE DAQ (CERN):
Chrisu-PC, Inv.Nr.: 401-925
-- Monitore
---- Belinea, Inv.Nr.: 401-696
---- Gericom, SN.: M1132GR5467345
-- Keyboard & Maus
Wiener 9U-VME-Crate, Inv.Nr.: 545-043, 2000EUR
-- Power Supply
-- VME-Controller
-- 4 VME-Module (1x Buffer, 1, Neco, 2x FADC)
DOCK-Box
-- Power Kabel
VME-Kabel (bockig) + Verlaengerung
30m-Kabel (8xCat7, 2xCat5, 2xgrau)
Lemo-Kabel
100pin-Flachkabel Neco-Buffer
Bananenkabel
Hybridkabel
Special TLU-Adapter (flipping pin order of RJ45)
Schrauben für Crate-Montage
Erdungskabel (liegen am CERN im Labor)
Magic Box
APVDAQ (Mol):
PC Inv.Nr: 401-943
-- Ilyama E2407, S/N 1105702000889
-- Keyboard & Maus
VME Crate Inv.Nr: 545-030
-- Create Controller Inv.Nr: 540-732
-- 3x APVDAQ
Repeater Board
-- 3x auf Platte montiert
Kabel
-- VME-Kabel (bockig)
-- 4x Netzwerk (gelb 1:1 verschalten)
-- 4x Netzwerk (grau 1:1 verschalten)
-- 1x Flachband
-- diverse Bananen
DUT:
Schraubenbox bau
-- diverse Schrauben
-- Gewindestangen
-- Fluegelmittern
-- 2x Sockel
4mm Steckschlauch fuer Trockenluft
Anschluss 1/8" auf 4mm Steckschlauch
Druckminderer
-- 6mm Snap-In
-- 6mm Schlauch
Chiller Huber ministat 230, Inv.Nr.: 482-021, 3000EUR
-- Manual
-- Netzteil
-- langes serielles Kabel
-- 5-6mm Schlauch
-- Adapter
-- 5 Liter dest. Wasser (falls noch Platz ist)
-- Frostschutz
-- LabView (falls ferngesteuert)
Box-Deckel
Baseplates (4?)
Schwarze Selbstklebefolie
Alufolie
GROSSES SCHWARZES LICHTDICHTES TUCH !!!!
Module
-- 2 x Micron Trapezoid
-- 2 x 6" Origami
-- 9 x Micron Baby
-- 2 x CNM 2D Sensoren
-- 8x SiLC (No. 0-7)
-- 2x Pt
EDV:
Netzwerk-Switch:
-- D-Link 8-Port GBit-Switch DGS1008D S/N F37v89B010104, 40 EUR
WLAN-Router: Linksys WRT54GL-DE, SN.: CL7B1H502248, 60 EUR
1TB externe Festplatte: Western Digital MyBook, SN.: WCAJ1469094, 40 EUR
-- Netzgeraet
-- USB-Kabel
-- Firewire 400/800 Kabel
Webcam
USB-Stick
Etikettiergeraet: Brother P-touch 1000
Laptops
-- Apple MacBook (MV) Inv.Nr.: 401-810
(-- Apple MacBook Pro (MD) Inv Nr.: 401-831)
2x USB-Seriell Adapter
Netzwerkkabel
1 Trommel Ethernet-Kabel (100m, vom Walzel)
einige RJ-45 Stecker
2.5" externe HD
CD/DVD Rohlinge
Tools:
Diverse Adaptoren Lemo-BNC, Lemo-Lemo
Taschenlampe + 2x Hirnbirn
Massband
Multimeter
Werkzeug (Schraubenzieher & Co)
Pinzetten
Laserpointer
Schwarze Fetzen
Gaffa
Doppelscotch
Kabelbinder
Druckluft zur Reinigung
Adapter f. Steckdosen
Verteiler-Leisten
Kabeltrommel
Schaltbare Steckerleisten
Tixo klein & gross
Loetstation Advanced JBC, SN.: 76841165, inkl. Zubehoer
Ethernet-Crimp-Zange
Eisensagl
Schublehre
Wasserwaage
Misc:
Fondueset
Spiegelreflex Digitalkamera
-- Stativ
-- Reflexionszelt
Scheinwerfer
-- 3 x 500 W
-- 2 x Stativ
Akkus+Ladegerät
Dickes Logbook
Kugelschreiber/Bleistifte
Pflaster
Carnet ATA |
Sun Oct 3 14:35:12 2010, Marko Dragicevic, CNM, cal, cal009, 83800, 03.10.2010 13:50:54,
|
CMN-SILC stack
HV_SILC (Katze)=75V, 0.25uA (6 SiLC)
HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
DUT outside of beam
calibration started after 1 hour warmup |
Mon Oct 4 10:43:45 2010, Marko Dragicevic, Pt, run, run036, 25600, 04.10.2010 10:33:05, 04.10.2010 11:35:51
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.9A h02=12.5A
HV=200V beam on
angle: 39 deg
telescope run 20142 |
Wed Oct 6 10:15:26 2010, Marko Dragicevic, Micron Baby, XY Positions After Irradiation, , , ,
|
center position: 119/50/(7.5)
top left (direction jura, bottom right on sensor): 127/56.5/7.5
bottom right (direction saleve, top left on sensor): 111/43.5/7.5 |
Wed Oct 6 11:03:59 2010, Marko Dragicevic, Micron Baby, cal, cal013, 83800, 06.10.2010 11:03:12,
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
# VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation)
ADC delay timing did not change after irradiation (verified)
|
Wed Oct 6 23:02:09 2010, Marko Dragicevic, common, Beam Configuration, , , ,
|
Beam Settings and Profile on 5.10.2010 - 17:00h
Saved as: H6B.801 |
Wed Oct 6 23:03:15 2010, Marko Dragicevic, BELLE, cal, cal014, 83800, 06.10.2010 23:01:56, 06.10.2010 23:34:07
|
Belle stack without Origami2
HV=80V I=227uA
beam on |
Thu Sep 23 15:32:28 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR, , , , 6x
|
p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen
n-side: Hybrid 32
APV4: 0-35 fail
APV5: 10-40, 68 fail
|
Thu Sep 23 15:37:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate, , , , 6x
|
p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)
APV4: 15-25 hoher noise, keine Fehler zu sehen -> Sensorfehler?
APV5: 127&128 kreuzen sich, beim Behebungsversuch mehr Schaden angerichtet -> besser mal die Finger davon lassen! |
Thu Sep 23 15:54:20 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING, , , , 6x
|
p-side: Hybrid 47
alles ok
n-side: Hybrid 38
APV5: Streifen 127 hoher Noise
ALS DUT VERWENDEN!
|
Thu Sep 23 16:00:31 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby2 -> TRACKING, , , , 6x
|
p-side: Hybrid 46
alles ok
n-side: Hybrid 37
APV4: 70-75 schlecht, nix zu sehen -> Sensorfehler
APV5: 115-128 schlecht, rebond fail?
FUER TRACKING GEEIGNET!
|
Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , , 6x
|
p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
n-side: Hybrid 30
APV5: 57-64 schlecht, rebond fail?
ALS DUT GEEIGNET!
|
Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , , 6x
|
p-side: Hybrid 41
alles ok
n-side: Hybrid 31
APV4: Streifen 0, 83 schlecht
APV5: Streifen 64, 88, 126 schlecht
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET! |
Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , , 6x
|
p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
APV3: beide Randstreifen etwas schlechter, nicht schlimm
n-side: Hybrid 36
APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
ALS DUT AUGENZUDRUECKEN GEEIGNET!
FUER TRACKING GEEIGNET!
|
Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , , 6x
|
p-side: Hybrid 44
alles ok
n-side: Hybrid 34
APV4: zur Gaenze schlecht, APV-Fehler?
APV5: beide Randstreifen schlecht
FUER TRACKING GEEIGNET!
|
Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , , 6x
|
p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33
APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
APV5: 111-128: 4 schlechte Streifen + common mode correction?
ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!
|
Fri Sep 24 12:09:32 2010, Manfred Valentan, BELLE, gds-file of Micron wafer, , , ,
|
|
Fri Oct 1 10:06:59 2010, Manfred Valentan, Micron Baby, run, run021, 75000, 01.10.2010 10:07:37, 01.10.2010 15:24:44
|
micron baby: 4 DUTs
HV=100V I=10.9uA (beginning) 13.6uA (end of run)
Beam on
60° rotation
telescope run 20116 |
Sun Oct 3 22:53:49 2010, Manfred Valentan, Pt, run, run033, 25600, 03.10.2010 22.47:38, 04.10.2010 00:02:37
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A
HV=200V beam on
angle: 33
telescope run 20138 |
Mon Oct 4 00:08:55 2010, Manfred Valentan, Pt, run, run034, 187000, 04.10.2010 00:03:18, 04.10.2010 09:22:07
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=21.9A h02=7.5A
HV=200V beam on
angle: 37
telescope run 20139 |
Mon Oct 4 09:31:25 2010, Manfred Valentan, Pt, run, run035, 25600, 04.10.2010 09:28:40,
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A
HV=200V beam on
angle: 35 deg
telescope run 20140 |
Mon Oct 4 14:15:22 2010, Manfred Valentan, Pt, run, run040 --> unusable --> no bias, 25600, 04.10.2010 14:?:?, 04.10.2010 14:32:14
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
HV=200V beam on
angle: 47 deg
telescope run 20146
bias voltage has been ramped down during run039 --> needs to be repeated. |
Mon Oct 4 23:12:16 2010, Manfred Valentan, BELLE, run, run44, 30000, 04.10.2010 23:?:?, 04.10.2010 23.57.23
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 30°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -22.5 (rotary table)
telescope run: 20150 |
Mon Oct 4 23:59:05 2010, Manfred Valentan, BELLE, run, run45, , 04.10.2010 ??:??:??, 05.10.2010 00:56:48
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 45°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -37.5 (rotary table)
telescope run: 20151 |
Tue Oct 5 10:20:30 2010, Manfred Valentan, BELLE, run, run46, 350000, 05.10.2010 01:00:00, 05.10.2010 10:16:07
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 15°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -7.5 (rotary table)
telescope run: 20152 |
Tue Oct 5 10:23:09 2010, Manfred Valentan, BELLE, run, run47, 30000, 05.10.2010 10:21:20, 05.10.2010
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 0°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: +7.5 (rotary table)
telescope run: 20153 |
Fri Oct 8 23:22:32 2010, Manfred Valentan, BELLE, Schnittwinkel barrel vs. slanted, , , ,
|
17deg acceptance => Schnittwinkel barrel option = 90-17 = 73deg -----> rotary table 80.5
layer zusätzlich slanted um Winkel alpha => Schnittwinkel = 73 - alpha
slant angles: layer 4: 11.9deg => Schnittwinkel 61.1deg -----> rotary table 68.6
layer 5: 17.2deg => Schnittwinkel 55.8deg -----> rotary table 63.3
layer 6: 21.1deg => Schnittwinkel 51.9deg -----> rotary table 59.4
Im Vergleich mit senkrechtem Durchgang der Teilchen erwarte ich eine Vergrößerung der cluster width um den Faktor tan(Schnittwinkel):
slant layer 4: 1.81
slant layer 5: 1.47
slant layer 6: 1.28
barrel: 3.27 |
Tue Oct 19 14:58:56 2010, Manfred Valentan, Micron Baby, geometry, , , ,
|
|
Thu Mar 31 10:28:19 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal100, , 31.03.2011 10:24:59, 31.03.2011 10:33:15
|
DUT5
cal-file: micronbaby_single_irrad_cal100.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=99muA
I_end=103muA
|
Thu Mar 31 11:05:39 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, run100, 100k, 31.03.2011 11:02:17, 31.03.2011 11:15:41
|
DUT5
cal-file: micronbaby_multi6_irrad_run100.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=104µA
I_end=111µA
|
Thu Mar 31 12:11:04 2011, Manfred Valentan, Micron Baby, DUT4, source run, post irrad, pre zupf, cal101, , 31.03.2011 12:09:36, 31.03.2011 12:17:52
|
DUT4
config file: micronbaby_single_irrrad_cal101.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=140µA
|
Thu Mar 31 12:24:24 2011, Manfred Valentan, Micron Baby, DUT4, source run, post irrad, pre zupf, run101, 100k, 31.03.2011 12:23:00, 31.03.2011 12:36:48
|
DUT4
config file: micronbaby_multi6_irrrad_run101.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=128µA
I_end=155µA
|
Fri Apr 8 13:25:58 2011, Manfred Valentan, Micron Baby, sensors and modules, , , ,
|
TRK1: B2Micron_2826_1_baby2
TRK2: B2Micron_2826_1_baby3
DUT3: B2Micron_2826_7_baby2 (common p-stop)
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
DUT5: B2Micron_2826_19_baby3 (atoll p-stop)
TRK6: B2Micron_2826_1_baby4
TRK7: B2Micron_2826_19_baby2
GEW: B2Micron_2826_7_baby4
not used: B2Micron_2826_7_baby3 |
Mon Apr 11 18:25:35 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, cal104, 83800, 11.04.2011 18:12:38, 11.04.2011 18:20:50
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=26µA
I_end=48µA
|
Mon Apr 11 18:37:28 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, pre zupf, run104, 100k, 11.04.2011 18:25:28, 11.04.2011 18:32:11
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=95µA
|
Wed Apr 13 12:13:09 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf ** DO NOT USE **, cal105, 83800, 13.04.2011 12:02:41, 13.04.2011 12:10:55
|
DUT5 (atoll), each second bond removed to simulate intermediate strips
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_single_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=18µA
I_end=21.5µA
data recorded with new switching power supplies and old intcal, which doesn't ignore bad strips!!!!! |
Wed May 11 16:28:07 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf, run106, 100k, 11.05.2011 16:00, 11.05.2011 16:25
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA
DAQ modified so that only strips marked as good are considered when calculating the common mode correction. |
Wed May 11 16:28:20 2011, Manfred Valentan, Micron Baby, DUT5, source run, post irrad, post zupf, cal106, 100k, 11.05.2011 16:00, 11.05.2011 16:25
|
DUT5 (atoll)
config file: D:/cern10/micronbaby/data_lab/DUT5/micronbaby_multi6_irrrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=52µA
I_end=120µA
DAQ modified so that only strips marked as good are considered when calculating the common mode correction. |
Tue May 17 13:02:34 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, cal107, 83800, 17.05.2011 12:20, 17.05.2011 12:35
|
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA |
Tue May 17 13:08:08 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, run107, 100k, 17.05.2011 12:39:34, 17.05.2011 13:03:05
|
DUT candidate common p-stop
TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA
n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate |
Tue May 17 13:31:32 2011, Manfred Valentan, Micron Baby, TRK2, source run, unirrad, prezupf, cal108, 83800, 17.05.2011 13:17:17, 17.05.2011 13:25:27
|
TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA |
Tue May 17 14:01:45 2011, Manfred Valentan, Micron Baby, TRK2, source run, unirrad, prezupf, run108, 100k, 17.05.2011 13:28:48, 17.05.2011 13:51:16
|
No DUT candidate (atoll p-stop)
TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA
n-side: APV4 most strips unusable, no DUT candidate |
Tue May 17 14:36:36 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, prezupf, cal109, 83800, 17.05.2011 14:18:13, 17.05.2011 14:34:25
|
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.8µA |
Tue May 17 14:37:23 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, prezupf, run109, 100k, 17.05.2011 14:34:32, 17.05.2011 15:00:02
|
DUT candidate combined p-stop
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.9µA
I_end=2.4µA
n-side zone 2 several unusable strips, zone 3 & 4 32 strips each suspicious. Nevertheless DUT candidate! |
Tue May 17 15:10:52 2011, Manfred Valentan, Micron Baby, TRK7, source run, unirrad, prezupf, cal110, 83800, 17.05.2011 15:16:25, 17.05.2011 15:24:35
|
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=1.7µA |
Tue May 17 17:43:24 2011, Manfred Valentan, Micron Baby, TRK7, source run, unirrad, prezupf, run110, 100k, 17.05.2011 15:39:37, 17.05.2011 16:02:54
|
DUT candidate common p-stop
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.8µA
I_end=2.1µA
n-side: highest 32 strips of APV5 noisy = half of zone 4. Rest okay, DUT candidate |
Tue May 17 17:44:12 2011, Manfred Valentan, Micron Baby, GEW8, source run, unirrad, prezupf, cal111, 83800, 17.05.2011 17:51:50, 17.05.2011 18:00:02
|
GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.6µA |
Tue May 17 18:33:07 2011, Manfred Valentan, Micron Baby, GEW8, source run, unirrad, prezupf, run111, 100k, 17.05.2011 18:01:41, 17.05.2011 18:23:24
|
NOT usable as DUT
GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=2.2µA
n-side: most of zones 1 and 3 unusable |
Tue May 17 18:49:16 2011, Manfred Valentan, Micron Baby, B2Micron_2826_7_baby3, source run, unirrad, prezupf, cal112, 83800, 17.05.2011 18:50:50, 17.05.2011 18:59:04
|
B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_single.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.2µA
I_end=1.4µA |
Tue May 17 18:53:33 2011, Manfred Valentan, Micron Baby, B2Micron_2826_7_baby3, source run, unirrad, prezupf, run112, 100k, 17.05.2011 19:00:21, 17.05.2011 19:22:45
|
DUT candidate atoll p-stop
B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/prezupf/micronbaby_multi6.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.4µA
I_end=1.8µA
n-side: looks very good except for a few strips in the middle of APV5 -> DUT candidate |
Tue May 17 19:08:29 2011, Manfred Valentan, Micron Baby, sensors for source test with intermediate strips, , , ,
|
Every second bond of these sensors will be removed to mimic the effect of an intermediate strip. For comparison, this is done both with irradiated and unirradiated sensors.
DUT3: B2Micron_2826_7_baby2, common p-stop, irradiated
DUT4: B2Micron_2826_19_baby4, combined p-stop, irradiated
DUT5: B2Micron_2826_19_baby3, atoll p-stop, irradiated (Wolfgang T. took this sensor to the SEM, it's destroyed by now)
TRK6: B2Micron_2826_1_baby4, combined p-stop, unirradiated
TRK7: B2Micron_2826_19_baby2, common p-stop, unirradiated
B2Micron_2826_7_baby3, atoll p-stop, unirradiated
|
Wed May 18 10:12:32 2011, Manfred Valentan, Micron Baby, DUT3, source run, unirrad, prezupf, cal113, 83800, 18.05.2011 09:42:08, 18.05.2011 09:50:23
|
DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=13µA
I_end=20µA |
Wed May 18 10:38:07 2011, Manfred Valentan, Micron Baby, DUT3, source run, irrad, prezupf, run113, 100k, 18.05.2011 10:03:15, 18.05.2011 10:25:14
|
DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/prezupf/micronbaby_single_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=20µA
I_end=26µA |
Wed May 18 12:06:42 2011, Manfred Valentan, Micron Baby, DUT4, source run, irrad, prezupf, cal114, 83800, 18.05.2011 11:42:22, 18.05.2011 11:50:36
|
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/prezupf/micronbaby_single_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=50µA
I_end=104µA |
Wed May 18 14:40:33 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, postzupf, cal115, 83800, 18.05.2011 13:41:44, 18.05.2011 13:49:58
|
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_single_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA
Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment! |
Wed May 18 14:42:49 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, postzupf, run115, 100k, 18.05.2011 13:53:54, 18.05.2011 13:53:54 6x
|
TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_multi6_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=1.8µA
Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment! |
Wed May 18 15:36:03 2011, Manfred Valentan, Micron Baby, TRK7, source run, unirrad, postzupf, cal116, 83800, 18.05.2011 14:43:18, 18.05.2011 14:51:31
|
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_single_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.6µA
I_end=1.7µA
every second bond zupfed... |
Wed May 18 15:38:29 2011, Manfred Valentan, Micron Baby, TRK7, source run, unirrad, postzupf, run116, 100k, 18.05.2011 15:02:05, 18.05.2011 15:24:07 6x
|
TRK7: B2Micron_2826_19_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK7/postzupf/micronbaby_multi6_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=2.3µA
every second bond zupfed... |
Wed May 18 16:31:12 2011, Manfred Valentan, Micron Baby, B2Micron_2826_7_baby3, source run, unirrad, prezupf, cal117, 83800, 18.05.2011 15:44:58, 18.05.2011 15:53:10
|
B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/postzupf/micronbaby_single_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA
Every second bond zupfed... |
Wed May 18 16:33:29 2011, Manfred Valentan, Micron Baby, B2Micron_2826_7_baby3, source run, unirrad, prezupf, run117, 100k, 18.05.2011 15:59:39, 18.05.2011 16:21:24 6x
|
B2Micron_2826_7_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/7baby3/postzupf/micronbaby_multi6_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.7µA
Every second bond zupfed... |
Thu May 19 09:42:28 2011, Manfred Valentan, Micron Baby, DUT3, source run, irrad, postzupf, cal118, 83800, 19.05.2011 08:56:18, 19.05.2011 09:04:30
|
DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/postzupf/micronbaby_single_irrad_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=14.9µA
I_end=17.6µA
Every second bond zupfed |
Thu May 19 09:44:39 2011, Manfred Valentan, Micron Baby, DUT3, source run, irrad, postzupf, run118, 100k, 19.05.2011 09:07:33, 19.05.2011 09:27:21 6x
|
DUT3: B2Micron_2826_7_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT3/postzupf/micronbaby_multi6_irrad_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=18.0µA
I_end=22.6µA
Every second bond zupfed |
Thu May 19 11:02:08 2011, Manfred Valentan, Micron Baby, DUT4, source run, irrad, postzupf, cal119, 83800, 19.05.2011 09:57:57, 19.05.2011 10:06:06
|
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_single_irrad_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=95µA
I_end=137µA
Every second bond zupfed... |
Thu May 19 11:04:04 2011, Manfred Valentan, Micron Baby, DUT4, source run, irrad, postzupf, run119, 100k, 19.05.2011 10:08:14, 19.05.2011 10:29:02 6x
|
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_multi6_irrad_postzupf.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=141µA
I_end=167µA
Every second bond zupfed... |
Thu May 19 11:06:41 2011, Manfred Valentan, Micron Baby, DUT4, source run, irrad, prezupf, run114, 100k, 18.05.2011 11:57:13, 18.05.2011 12:13:12
|
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/prezupf/micronbaby_multi6_irrad.cfg
HV=+-50V
90Sr 1mCi ~centered
I_start=118µA
I_end=168µA
keine hitmaps gespeichert... |
Fri Oct 1 09:33:45 2010, Immanuel Gfall, common, Eudet Hit Correlation, Num Clusters Screenshots, 20115, 161135, 9:30, 9:30
|
[IMG]49/2[/IMG] |
Wed Sep 29 11:53:16 2010, Erik Huemer, BELLE, run, run011, 19003, 29.09.2010 12:19:57, 29.09.2010 14:00:57
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=83.22µA, beam on
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered
telescope run 20085 (continued) |
Fri Oct 1 09:42:02 2010, Erik Huemer, Micron Baby, run, run020, 1843, 01.10.2010 09:59:09 , 01.10.2010 10.05
|
micron baby: 4 DUTs
HV=100V I=10.9uA
Beam on
60° rotation
Teleskop nicht neu gestartet, machma nochamal |
Sat Oct 2 15:24:00 2010, Erik Huemer, ITE, XY Position and Slow Control, , , ,
|
center position: 119/48/187,5
|
Sun Oct 3 16:23:20 2010, Erik Huemer, Pt, XY/R Position, , , ,
|
centerposition: 119/43/187,5
27 grad: 214,5 |
Sun Oct 3 20:44:40 2010, Erik Huemer, Pt, run, run031, 25600, 03.10.2010 19:42:34,
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=20.5A h02=6.5A
HV=200V beam on
angle: 29
telescope run 20135 |
Sun Oct 3 21:49:19 2010, Erik Huemer, Pt, run, run032, 25600, 03.10.2010 21:44:30, 03.10.2010 22.40.07
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A
HV=200V beam on
angle: 31
telescope run 20136 |
Mon Oct 4 12:24:38 2010, Erik Huemer, Pt, run, run038, 25600, 04.10.2010 12:22:09, 04.10.2010 12:43:40
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.6A h02=13.1A
HV=200V beam on
angle: 43 deg
telescope run 20144 |
Mon Oct 4 12:50:13 2010, Erik Huemer, Pt, run, run039 --> run out of air --> repeat, 25600, 04.10.2010 12:45:17, 04.10.2010 14:00:00
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
HV=200V beam on
angle: 45 deg
run out of dry air --> h01 run into compliance --> HV turned off during run automatically --> has to be repeated
telescope run 20145 |
Tue Sep 28 14:38:24 2010, Christian Irmler, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in
channel 2: Origami_mod1_out
channel 3: Origami_mod2_in
channel 4: Origami_mod2_out
channel 5: Micron_wedge_mod1_p
channel 6: Micron_wedge_mod1_n
channel 7: Micron_wedge_mod2_p
channel 8: Micron_wedge_mod2_n
The cooling pipes of the two Origami modules and that of the Micron modules are connected in series, respectively. |
Thu Sep 30 10:56:34 2010, Christian Irmler, common, Room numbers, , , ,
|
Room and telefone numbers.
Name |
Building |
Room |
Tel. |
Bergi |
38 |
418 |
70 418 or 162471 (mobile) |
Markus |
41 |
021 |
60 021 |
Manfred |
38 |
404 |
70 404 |
Erik |
38 |
463 |
70 463 |
Immanuel |
38 |
313 |
70 313 |
Chrisu |
39 |
324 |
79 324
|
Marko |
39 |
007 |
79 007 |
Paqui |
38 |
107 |
70 107 |
|
Sun Oct 3 18:23:27 2010, Christian Irmler, Pt, cal, cal010, 83800, 03.10.2010 18:26:49 ,
|
pt modules angle scan
h01-Pt and h02-Pt
currents: h01=23.1µA h02=10.4µA
HV=200V
beam on
modules flushed with dry air
|
Sun Oct 3 18:52:56 2010, Christian Irmler, Pt, run, run030, 25600, 03.10.2010 19:16:29,
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=23.1A h02=10.4A
HV=200V beam on
angle: 27
telescope run 20134 |
Mon Oct 4 11:43:05 2010, Christian Irmler, Pt, run, run037, 25600, 04.10.2010 11:40:15, 04.10.2010 12:15:03
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=25.4A h02=13.1A
HV=200V beam on
angle: 41 deg
telescope run 20143 |
Mon Oct 4 15:39:34 2010, Christian Irmler, Pt, run, run041, 25600, 04.10.2010 15:46:22,
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
HV=200V beam on
angle: 45 deg
position axis = 232.5
repetition of run039
telescope run20147 |
Mon Oct 4 16:15:48 2010, Christian Irmler, Pt, run, run042, 25600, 04.10.2010 16:12:52, 04.10.2010 16:35:18
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=28.1A h02=2.4A
HV=200V beam on
angle: 47 deg
repetition of run040, but now biased :-)
telescope run 20148 |
Mon Oct 4 16:29:36 2010, Christian Irmler, common, beam settings, , , ,
|
beam settings optimized by beamline operator
wire champer display fixed |
Mon Oct 4 20:16:19 2010, Christian Irmler, BELLE, cal, cal011, 83800, 04.10.2010 20:15:00,
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
HV connection of Origami 1 repaired |
Mon Oct 4 21:01:25 2010, Christian Irmler, BELLE, run, run43, 30000, 04.10.2010 20:59:48, 04.10.2010 23:04:24
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C
angle: 60°
axis 1: 92.4 (horizontal)
axis 2: 35 (vertical)
axis 3: -52.5 (rotary table)
telescope run: 20149 |
Tue Oct 5 17:50:23 2010, Christian Irmler, ITE, cal, cal012, 83800, 05.10.2010 17:50:26, 05.10.2010 18:09:48
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
Tue Oct 5 18:13:05 2010, Christian Irmler, ITE, run, run048, 533125, 05.10.2010 18:14:57, 06.10.2010 09:27:44
|
6 x SILC + 2 x ITE
HV=100V
telescope position: 124/48
telescope run: 20154-20155
DUTs and SILC4/5 swapped
new module order (downstream): SILC0 - SILC3 - SILC1 - W7 - W9 - SILC2 - SILC4 -SILC5
SILC1 and SILC2 are horizontal
beam on
modules flushed with dry air (black tube)
rel. humidity: ~0% @ 26°C |
Fri Oct 8 18:12:15 2010, Christian Irmler, BELLE, run, run053, 98000, 08.10.2010 00:33:14, 08.10.2010 13:36:57
|
Belle stack w/o Origami2 after irradiation
HV=80V
Telescope position 55/30/277.5
NIM trigger
temperature of chiller set to 15°C
Analog signal of APVs #22 and #23 has been bound to ground after 1200 events. |
Fri Oct 8 23:43:07 2010, Christian Irmler, BELLE, run, run055, 12316, 08.10.2010 23:42:51, 09.10.2010 00:14:56
|
Belle stack w/o Origami2 after irradiation
HV=80V / 255 µA
cooling: Origami only, chiller set to -25°C,
2 suspicious APVs on n side of Micron due to burnt strip
same position as in previous run
telescope run 20197 - wrong config file @ telescope -> new run with correct settings |
Sat Oct 9 12:00:55 2010, Christian Irmler, BELLE, cal, cal017, 83800, 09.10.2010 11:59:37,
|
Origami1 (n-side only) + Micron1 (non-irrad)
angle scan: 73°
HV=100V / 40 µA
cooling: chiller set to 15°C
Origami p-side does not receive triggers -> disabled
origami flex straight part needed to be folded due to severe rotation angle -> nanonics connector problem... |
Mon Oct 11 11:18:17 2010, Christian Irmler, common, end of success, , , 09.10.2010 19:44:23, NaN
|
der Beiweis :-) |
|