Message ID: 77     Entry time: Mon Oct 4 14:15:22 2010
Author: Manfred Valentan 
Project: Pt 
Subject: run 
Run Number: run040 --> unusable --> no bias 
Events: 25600 
StartTime: 04.10.2010 14:?:? 
EndTime: 04.10.2010 14:32:14 

Pt modules, angle scan

h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
HV=200V beam on
angle: 47 deg

telescope run 20146

bias voltage has been ramped down during run039 --> needs to be repeated.