Message ID: 147     Entry time: Thu May 19 11:02:08 2011
Author: Manfred Valentan 
Project: Micron Baby 
Subject: DUT4, source run, irrad, postzupf 
Run Number: cal119 
Events: 83800 
StartTime: 19.05.2011 09:57:57 
EndTime: 19.05.2011 10:06:06 

DUT4: B2Micron_2826_19_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/DUT4/postzupf/micronbaby_single_irrad_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=95µA
I_end=137µA

Every second bond zupfed...