| ID | Date | Author | Project | Subject | Run Number | Events  | StartTime | EndTime | Text |  | 
| 41 | Fri Aug 21 06:16:15 2009 | Christian Irmler | BELLE | internal calibration 40 MHz transparent mode | cal003 |  | 20.08.2009  23:27:12 | 21.08.2009  00:05:16 | Belle DUT, intcal HV=80V, 40 MHz, no beam
 transparent mode
 |  | 
| 49 | Fri Aug 21 12:08:44 2009 | Christian Irmler | BELLE | APVDAQ  standalone 40 MHz | pedcorr003 |  | 21.08.2009  12:08:33 | 21.08.2009  12:18:45 | 4 Belle DUTs HV=80V, 40 MHz
 pedestal correction
 |  | 
| 52 | Fri Aug 21 14:18:11 2009 | Christian Irmler | BELLE | internal calibration 31.8 MHz transparent mode | cal004 |  | 21.08.2009  14:21:40 | 21.08.2009  15:01:24 | Belle DUT, intcal HV=80V, 31.8 MHz, no beam
 transparent mode
 |  | 
| 53 | Fri Aug 21 15:27:08 2009 | Christian Irmler | BELLE | internal calibration 31.8 MHz hit mode | cal005 |  | 21.08.2009  15:34:43 | 21.08.2009  16:29:47 | Belle DUT, intcal HV=80V, 31.8 MHz, no beam
 hit mode
 |  | 
| 54 | Fri Aug 21 16:37:22 2009 | Christian Irmler | BELLE | internal calibration 40 MHz hit mode | cal006 |  | 21.08.2009  16:30:33 |  | Belle DUT, intcal HV=80V, 40 MHz, no beam
 hit mode
 |  | 
| 55 | Fri Aug 21 17:14:58 2009 | Wolfgang Kiesenhofer |  | S/N Histograms Raw (no data selection) | run001 (strips), run002 (pitch adapter), run003 (upper edge) |  |  |  |  |     | 
| 56 | Fri Aug 21 18:07:57 2009 | Christian Irmler | BELLE | APVDAQ  standalone 31.8 MHz | pedcorr004 |  | 21.08.2009  17:49:10 | 21.08.2009  18:24:31 | 4 Belle DUTs HV=80V, 31.8 MHz
 pedestal correction
 |  | 
| 58 | Fri Aug 21 22:42:32 2009 | Thomas Bergauer | common | EUDAQ config file used when running with telescope |  |  |  |  | 
 |   | 
| 65 | Sat Aug 22 11:54:49 2009 | Thomas Bergauer | common | beam profile |  |  |  |  | beam shifted a bit in vertical direction downwards since 21. August 09 evening
 
 |   | 
| 66 | Sat Aug 22 12:12:34 2009 | Christian Irmler | BELLE | internal calibration 40 MHz  transparent mode (cooling?) | cal007 |  | 22.08.2009  12:10:32 | 22.08.2009  12:49:09 | Belle DUT, intcal HV=80V, 40 MHz, beam off
 1 sample, transparent mode
 |  | 
| 67 | Sat Aug 22 13:28:53 2009 | Wolfgang Kiesenhofer | Pt_ITE512 | runlist for pt-module angle-scan |  |  |  |  | Preliminary run list for pt-modules + ite512 + silc1, silc2,
 silc5, silc6
 |  | 
| 68 | Sat Aug 22 13:30:28 2009 | Christian Irmler | BELLE | internal calibration 31.8 MHz  transparent mode (cooling?) | cal008 |  | 22.08.2009  12:50:48 | 22.08.2009  13:29:25 | Belle DUT, intcal HV=80V, 31.8 MHz, beam off
 1 sample, transparent mode
 |  | 
| 69 | Sat Aug 22 13:34:14 2009 | Christian Irmler | BELLE | pedestal correction 31.8 MHz  transparent mode (cooling?) | pedcorr005 |  | 22.08.2009  13:31:27 | 22.08.2009  13:41:42 | Belle DUT, intcal HV=80V, 31.8 MHz, beam off
 1 sample, transparent mode
 |  | 
| 70 | Sat Aug 22 14:46:12 2009 | Christian Irmler | BELLE | internal calibration 31.8 MHz  transparent mode + cooling | cal009 |  | 22.08.2009  14:43:55 | 22.08.2009  15:22:37 | Belle DUT, intcal HV=80V, 31.8 MHz, beam off
 1 sample, transparent mode
 |  | 
| 71 | Sat Aug 22 15:12:44 2009 | Thomas Bergauer | common | beam profile |  |  |  |  | playing with TRIM4 in vertical plane (setting to 20A current) shifted beamspot
 back to center position
 |   | 
| 72 | Sat Aug 22 15:28:00 2009 | Christian Irmler | BELLE | pedestal correction 31.8 MHz  transparent mode + cooling | pedcorr006 |  | 22.08.2009  15:25:35 | 22.08.2009  15:36:00 | Belle DUT, HV=80V, 31.8 MHz, beam off 1 sample, transparent mode
 pedestal correction
 |  | 
| 75 | Sat Aug 22 22:14:50 2009 | Christian Irmler | BELLE | internal calibration 40 MHz  transparent mode + cooling | cal010 |  | 22.08.2009  22:24:22 |  | Belle DUT, intcal HV=80V, 40 MHz, beam off
 1 sample, transparent mode
 |  | 
| 76 | Sat Aug 22 23:06:22 2009 | Christian Irmler | BELLE | pedestal correction 40 MHz  transparent mode + cooling | pedcorr007 |  | 22.08.2009  23:04:29 | 22.08.2009  23:13:51 | Belle DUT, HV=80V, 40 MHz, beam off 1 sample, transparent mode
 pedestal correction
 |  | 
| 80 | Sun Aug 23 13:15:42 2009 | Marko Dragicevic | Pt_ITE512 | Current and Humindity during first Run |  |  |  |  | Current of Pt modules during first run Data
 of the run was dicarded.
 Compressed air flow was at ~2 bars
 |    | 
| 82 | Sun Aug 23 17:18:25 2009 | Christian Irmler | Pt_ITE512 | pedestal correction | pedcorr008 |  | 23.08.2009  17:17:36 |  | Pt: 1 Grad, HV=200V, 0% RH, intcal, beam off
 ITE512: HV=70V,
 |  |