[RunControl] RunSizeLimit = 1800000000 NoTrigWarnTime = 10 [DataCollector] [LogCollector] SaveLevel = EXTRA PrintLevel = INFO [Producer.TLU] AndMask = 0xc # 9x9 mm scintillaotr for trigger #AndMask = 0xf # 4x4 mm scintillator for trigger OrMask = 0 VetoMask = 0 # EUDRB plugged into DUT#4 , FORTIS plugged into DUT#1, SiLC plugged into DUT#0 #DutMask = 20 # EUDRB, FORTIS, SiLC in DutMask = 17 # FORTIS, SiLC in EnableDUTVeto = 2#0 TriggerInterval = 0 TrigRollover = 0 StrobePeriod = 16000000 StrobeWidth = 480000 [Producer.EUDRB] Version = 2 Det = MIMOTEL Mode = ZS Unsynchronized = 1 AdcDelay = 3 ClkSelect = 2 #Marker1 = 0xff #Marker2 = 0xff PostDetResetDelay = 4 PedestalFile = auto IDOffset = 0 NumBoards = 6 Board0.Slot = 3 Board1.Slot = 5 Board2.Slot = 7 Board3.Slot = 9 Board4.Slot = 11 Board5.Slot = 13 [Producer.FORTIS] # Need \ not / for directory name with Cygwin... # ExecutableDirectory = /home/cussans/optodaq/halsall_test_v5/ ExecutableDirectory = /home/cussans/optodaq/MyF11/ # ExecutableDirectory = /home/cussans/optodaq/MyF10/ ExecutableProcessName = optodaqV.exe #ExecutableFilename = test_run_128_block_mod_C2.bat ExecutableFilename = test_run_512_128_block_mod_CX.bat # ExecutableFilename = test_run_512_448_block_mod_full.bat ExecutableArgs = NumRows = 512 NumColumns = 128