Message ID: 70     Entry time: Sat Aug 22 14:46:12 2009
Author: Christian Irmler 
Project: BELLE 
Subject: internal calibration 31.8 MHz transparent mode + cooling 
Run Number: cal009 
Events:  
StartTime: 22.08.2009 14:43:55 
EndTime: 22.08.2009 15:22:37 

Belle DUT, intcal
HV=80V, 31.8 MHz, beam off
1 sample, transparent mode
cooling
chiller set to 13 deg.

Since there was no (or to less) water flow through the small pipe of the origami module, all previous runs with cooling must be repeated.

Bypass removed to achieve better watter flow at the module!
Chiller pump is set to 2800 rpm