Fri Apr 14 00:12:05 2017, Johannes Grossmann, MaPSA, Teleskope Correlation, 48, 50000, 0, No, Unknown
|
Telescope 1288
Threshold 90
Mapsa CLK Delay 20 ns |
Fri Apr 14 00:12:53 2017, Johannes Grossmann, MaPSA, Teleskope Correlation, 49, 50000, 0, No, Unknown
|
Telescope 1292
Threshold 90
Mapsa CLK Delay 20 ns |
Fri Apr 14 00:22:30 2017, Johannes Grossmann, MaPSA, Teleskope Correlation, 50, 50000, 0, No, Unknown
|
Telescope 1292
Threshold 90
Mapsa CLK Delay 22 ns |
Fri Apr 14 00:40:23 2017, Johannes Grossmann, MaPSA, Teleskope Correlation, 51, 50000, 0, No, Unknown
|
Telescope 1294
Threshold 90
Mapsa CLK Delay 24 ns |
Sat Apr 15 21:18:26 2017, Axel Koenig, ALiBaVa (IFX), run_007_Baby_10V.dat, 007, 450000, 102.5, 22.5, 240, No, Crap
|
Remarks: Telescope run 579. Bias scan 10 V. run crashed. Data vaild up to 274915.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_Baby_10V.dat |
Telescope run |
579 |
Triggers |
450000 |
Alibava trigger eff. |
~24% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-10 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 13:30:01 2017, Axel Koenig, ALiBaVa (IFX), run_001_HPK_CB_200V.dat, 001, 450000, 107, 0, 240, No, Unknown
|
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_001_HPK_CB_200V.dat |
Telescope run |
604 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
0 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 16:36:56 2017, Axel Koenig, ALiBaVa (IFX), run_002_HPK_CB_200V.dat, 002, 450000, 107, 5.8, 240, No, Unknown
|
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
Wed Apr 19 17:31:43 2017, Axel Koenig, ALiBaVa (IFX), run_001_Irrad_100V.dat, 001, 400000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 628. Bias scan -100V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_001_Irrad_100V.dat |
Telescope run |
628 |
Triggers |
400000 |
Alibava trigger eff. |
~49% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
23.5 uA |
|
Wed Apr 19 19:27:38 2017, Axel Koenig, ALiBaVa (IFX), run_002_Irrad_200V.dat, 002, 400000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 630. Bias scan -200V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_002_Irrad_200V.dat |
Telescope run |
630 |
Triggers |
400000 |
Alibava trigger eff. |
~65% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
29.7 uA |
|
Fri Apr 14 14:49:09 2017, Axel Koenig, ALiBaVa (IFX), run_023_IFX_CB_100V.dat, 023, 385000, 109, 0, 240, No, Crap
|
Remarks: Telescope run 546. Bias voltage 100 V. Beam position on only one chip. Run destroyed. Intended trigger count 500k
Parameter |
Value |
Alibava run |
run_023_IFX_CB_100V.dat |
Telescope run |
546 |
Triggers |
385000 |
Alibava trigger eff |
~62 % |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 V |
Latency |
132 |
Table x |
109 mm |
table z |
0 mm |
table rot |
240 deg (parallel to tele. planes) |
|
Tue Apr 18 21:03:42 2017, Axel Koenig, ALiBaVa (IFX), run_003_double_irrad_100V.dat, 003, 3500000, 103, 1, 240, No, Unknown
|
Remarks: Telescope run 625. Both chips. Central position. Run crashed over night.
Collected triggers 2710991.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_003_double_irrad_100V.dat |
Telescope run |
625 |
Triggers |
3500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
103 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
Fri Apr 14 18:22:58 2017, Axel Koenig, ALiBaVa (IFX), run_026_IFX_CB_100V.dat, 026, 350000, 109, 4.5, 230, No, Unknown
|
Remarks: Telescope run 549. Angle shift 230 deg.
Parameter |
Value |
Alibava run |
run_026_IFX_CB_100V.dat |
Telescope run |
549 |
Triggers |
350000 |
Alibava trigger eff. |
~59.8% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
230 deg
|
|
Fri Apr 14 19:43:13 2017, Axel Koenig, ALiBaVa (IFX), run_027_IFX_CB_100V.dat, 027, 350000, 109, 4.5, 250, No, Unknown
|
Remarks: Telescope run 550. Angle shift 250 deg.
Parameter |
Value |
Alibava run |
run_027_IFX_CB_100V.dat |
Telescope run |
550 |
Triggers |
350000 |
Alibava trigger eff. |
~59.8% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
250 deg
|
|
Tue Apr 18 08:07:15 2017, Axel Koenig, ALiBaVa (IFX), run_010_HPK_CB_200V.dat, 010, 350000, 107, 2.6, 240, No, Unknown
|
Remarks: Telescope run 616. Short run central position. Repeated due to crash over night.
No beam during run.Only ~10000 events.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_010_HPK_CB_200V.dat |
Telescope run |
616 |
Triggers |
350000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
Tue Apr 18 18:19:33 2017, Axel Koenig, ALiBaVa (IFX), run_001_double_irrad_100V.dat, 001, 350000, 111, 1, 240, No, Unknown
|
Remarks: Telescope run 620. 2nd chip only. Central position.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_001_double_irrad_100V.dat |
Telescope run |
620 |
Triggers |
350000 |
Alibava trigger eff. |
~53% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
111 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
Fri Apr 14 21:11:18 2017, Axel Koenig, ALiBaVa (IFX), run_028_IFX_CB_100V.dat, 028, 3000000, 109, 4.5, 240, No, Crap
|
Remarks: Telescope run 551. Longrun over night. Run crashed. Events only up to 2288000 valid.
Parameter |
Value |
Alibava run |
run_028_IFX_CB_100V.dat |
Telescope run |
551 |
Triggers |
3000000 |
Alibava trigger eff. |
~60 % |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 19:54:08 2017, Axel Koenig, ALiBaVa (IFX), run_007_HPK_CB_150V.dat, 007, 300000, 107, 2.6, 240, No, Unknown
|
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_HPK_CB_150V.dat |
Telescope run |
611 |
Triggers |
300000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
Wed Apr 19 20:55:36 2017, Axel Koenig, ALiBaVa (IFX), run_003_Irrad_300V.dat, 003, 300000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 632. Bias scan -300V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_003_Irrad_300V.dat |
Telescope run |
632 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-300 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
35.1 uA |
|
Thu Apr 20 09:31:58 2017, Axel Koenig, ALiBaVa (IFX), run_008_Irrad_550V.dat, 008, 300000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 638. Bias scan -550V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_008_Irrad_550V.dat |
Telescope run |
638 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-550 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
41.8 uA |
|
Thu Apr 20 12:55:02 2017, Axel Koenig, ALiBaVa (IFX), run_010_Irrad_650V.dat, 010, 300000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 640. Bias scan -650V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_010_Irrad_650V.dat |
Telescope run |
640 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-650 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |