Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle testbeam at SPS in June 2015, Page 2 of 6  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Projectdown Subject Run Number Events XYPosition Cooling Data
  46   Mon Jun 8 01:28:58 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and Telescopehw0554100007NoGood

RUN WITH SVD3 plus telescope

EUDET Run 55

Mimosa Threshold 6

Pos 7: x= 30.5 mm, y= 79 mm (wide side center)

  48   Mon Jun 8 09:37:30 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and Telescopehw056500008NoGood

RUN WITH SVD3 plus telescope

EUDET Run 56

Mimosa Threshold 6

Pos 8: x=136.08 mm, y= 79 mm (narrow side center)

Attachment 1: run000056-fitter-residuals.pdf
  49   Mon Jun 8 10:47:44 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and Telescopehw057500009NoGood

RUN WITH SVD3 plus telescope

EUDET Run 57

Mimosa Threshold 6

Pos 9: x=30.5 mm, y= 60.67 mm (wide side down)

Attachment 1: run000057-fitter-residuals.pdf
  51   Mon Jun 8 11:57:14 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and Telescopehw0585000010NoGood

RUN WITH SVD3 plus telescope

EUDET Run 58

Mimosa Threshold 6

Pos 10: x= 136.08mm, y=68.9 mm (narrow side down)

  53   Mon Jun 8 15:03:53 2015 Benedikt WürknerSVD3 (H6B)hardware run with TLU and FEI4 WORKING5919000  Unknown

Testrun with the FEI4 working for the first time. 

Lessons learned about the configuration:

EnableDUTVeto needs to be set for the FEI4 to allow it to work

HandShakeMode needs to be enabled for the FEI4 as well

"Enable RJ45 input during scans" needs to be enabled for the USB-controller

  54   Mon Jun 8 15:49:23 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI4605000010NoUnknown

Hardware run with FEI4, Telescope and FW&BW Modules

Pos 10: x= 136.08mm, y=68.9 mm (narrow side down)

 

Bilder: Hitmap FE-I4 und Correlation zw. Mimosa und FE-I4

Attachment 1: Screenshot_2015-06-08_17.59.50.png
Screenshot_2015-06-08_17.59.50.png
Attachment 2: Screenshot_2015-06-08_17.41.03.png
Screenshot_2015-06-08_17.41.03.png
  56   Mon Jun 8 16:53:13 2015 Benedikt WürknerSVD3 (H6B)EUTelescope Fitter not working investigation    Unknown

Apparently every problem can be attributed to a misalignment problem. The telescope has troubles with heavily misaligned DUTs. Was resolved by creating different gear-files for each run with pretty precise coordinates of the DUT position calculated for the telescope coordinate system. 

Additionally one has to watch out for misaligned planes of the telescope itself. It was required to allow for more than 2mm offset for the telescope planes behind the DUTs. This can be easily checked by looking at the PreAligner plots in the -hitmaker-histo.root file.

It look something like this:

and not like this:

 

Run number offset value Comment
49 -1  
50 -1 Expected default value. EORE=49401
51 -1 Expected default value. EORE=49400
52 -1 Checked -1 EORE= 49401
53 -1 Checked -1 EORE= 49401
54 -1 Checked -1 EORE= 119401, 
55 -1 Checked -1 EORE= 409388
56 -1 Checked -1 EORE= 49392
57 -1 Checked -1 EORE= 49377
58 -1 Checked -1 EORE= 49397

 

Run Position x-Table x-telescope FW x-telescope BW
49 1 100 -13,7 -16,7
50 2 69,3 17 14
51 3 38,6 47,7 44,7
52 4 130,7 -44,4 -47,4
53 5 30,5 55,8 52,8
54 6 136,8 -50,5 -53,5
55 7 30,5 55,8 52,8
56 8 136,8 -50,5 -53,5
57 9 30,5 55,8 52,8
58 10 136,8 -50,5 -53,5
Attachment 2: bad-alignment.png
bad-alignment.png
  57   Mon Jun 8 18:00:06 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI4hw061500002NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 61

Mimosa Threshold 6

Pos 2: x=69.3 mm, y=79 mm (Hits in APV 3-4 und 8-9 in p-Seite und 13 und 18 in n-Seite) 

  58   Mon Jun 8 18:08:49 2015 Thomas BergauerSVD3 (H6B)Telescope online monitor    Unknown

a working version of the EUDET online monitor (which works also with the FE-I4) is at the following location

~/BELLETEST/eudaq-neu/build/monitors/onlinemon$ ./OnlineMon.exe -sc 0 -f /home/telescope/eudaq/data/run000060.raw

  60   Mon Jun 8 20:16:41 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI462500003NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 62

Mimosa Threshold 6

Pos 3: x=38.6 mm, y=84 mm

  61   Mon Jun 8 22:11:07 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI4634900004NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 63

Mimosa Threshold 6

Pos 4: x=130.7 mm, y=84 mm

  64   Tue Jun 9 09:50:15 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI464500005NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 64

Mimosa Threshold 6

Pos 5: x=30.5 mm, y= 99.74 mm (wide side top)

  66   Tue Jun 9 10:01:03 2015 Lukas BullaSVD3 (H6B)TLU setup info    Unknown

Channels:

  • Upstream vertical -> channel 0; (bitmask 1)
  • Upstream horizontal -> channel 1; (bitmask 2)
  • Downstream vertical -> channel 2; (bitmask 4)
  • Downstream horizontal ->channel 3; (bitmask 8)

 

TLU DuT interface:

DUT Interface Bitmask DAQ
1 1 Mimosa (EUDET Telescope)
2 2 leer
3 4 SVD3
4 8 FE-I4

 

Attachment 1: upstream.jpg
upstream.jpg
Attachment 2: downstream.jpg
downstream.jpg
  67   Tue Jun 9 11:20:25 2015 Benedikt WürknerSVD3 (H6B)Vertical Beam Profile Run65500002NoUnknown

Trying to get a nice plot of the beam profile by only using the vertical PMTs (number 0 and 2) see http://elog.hephy.at/testbeam-SPS2015/66 for details. 

Pos 2: x=69.3 mm, y=79 mm (Hits in APV 3-4 und 8-9 in p-Seite und 13 und 18 in n-Seite) 

Producer.TLU Config Change:

  • AndMask=0x5
  68   Tue Jun 9 12:34:16 2015 Benedikt WürknerSVD3 (H6B)Horizontal Beam Profile Run66500002NoUnknown

Trying to get a nice plot of the beam profile by only using the PMTs 1 and 3 (horizontal)  see http://elog.hephy.at/testbeam-SPS2015/66 for details. 

Pos 2: x=69.3 mm, y=79 mm (Hits in APV 3-4 und 8-9 in p-Seite und 13 und 18 in n-Seite) 

Producer.TLU Config Change:

  • AndMask=0xa (10 in hex) 
  69   Tue Jun 9 14:33:50 2015 Benedikt WürknerSVD3 (H6B)Vertical Beam Profile Run67500002NoUnknown

Trying to get a nice plot of the beam profile by only using the vertical PMT 0 (upstream vertical, the long one)  see http://elog.hephy.at/testbeam-SPS2015/66 for details. 

Pos 2: x=69.3 mm, y=79 mm (Hits in APV 3-4 und 8-9 in p-Seite und 13 und 18 in n-Seite) 

Producer.TLU Config Change:

  • AndMask=0x1 
  70   Tue Jun 9 16:22:59 2015 Benedikt WürknerSVD3 (H6B)Beam Profile Results66 und 67 2NoGood
Attachment 1: HW_066_002_Result.pdf
Attachment 2: HW_066_003_Result.pdf
Attachment 3: HW_067_000_Result.pdf
Attachment 4: HW_067_001_Result.pdf
  71   Tue Jun 9 20:27:55 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI4685035058NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 68

Mimosa Threshold 6

Pos 8: x=136.08 mm, y= 79 mm (narrow side center)

  80   Wed Jun 10 18:05:03 2015 Benedikt WürknerSVD3 (H6B)FEI4 configuration   NoUnknown

There are two planes, one fixed upstream and one fixed downstream. 

CIS3WII_6 upstream and CIS2WI_IBL2 downstream.

They are configured using the pc in H6B which can be accessed via microsoft remote desktop from the network 192.168.5.x using the ip 192.168.5.6. 

The configuration files can be found in the folder "E:\ConfigurationCMS\" on the server and are named after the modules. 

Only one of the FEI4 detectors can be used at a time since they are of different generations (FEI4A and FEI4B) which can't be used at the same time with the available USB board. vnc

The configuration for EUDAQ needs to be adapted for the used module by changing the name of the configuration file. 

[Producer.USBpixI4]
SRAM_READOUT_AT = 5
SkipConfiguration = no
UseSingleBoardConfig = no
boards = 230
modules[230] = 1
#upstream
config_file = E:\ConfigurationCMS\CIS3_W11_06_thr1600_7to21ke_modified.cfg.root
#downstream:
#config_file = E:\ConfigurationCMS\CIS2_W02_IBL1_thr1600_7to14_modified.cfg.root
fpga_firmware = E:\icwiki_svn\USBPixI4\host\tags\release-5.3\config\usbpixi4.bit
lvl1_delay = 16
tlu_trigger_data_delay = 10

In my experience switching between the planes also requires a restart of the USBPix DAQ because apparently something is not working with the reload of a different config file afterwards. I had the phenomenon that the DAQ responded like it was working but the datastream was empty. Therefore always check the online monitor for hitmaps. 

  82   Wed Jun 10 19:05:04 2015 Benedikt WürknerSVD3 (H6B)Hardware FEI471500001NoUnknown

RUN WITH SVD3, telescope and FEI4

EUDET Run 71

Mimosa Threshold 6

Pos 1: x=100 mm, y=79 mm (Hits in APV 3 und 8-9 in p-Seite und 14 und 17 in n-Seite )

Downstream FEI4 used

ELOG V3.1.5-fc6679b