Message ID: 53     Entry time: Mon Jun 8 15:03:53 2015
Author: Benedikt Würkner 
Project: SVD3 (H6B) 
Subject: hardware run with TLU and FEI4 WORKING 
Run Number: 59 
Events: 19000 
XYPosition:  
Cooling:  
Data: Unknown 

Testrun with the FEI4 working for the first time. 

Lessons learned about the configuration:

EnableDUTVeto needs to be set for the FEI4 to allow it to work

HandShakeMode needs to be enabled for the FEI4 as well

"Enable RJ45 input during scans" needs to be enabled for the USB-controller