Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, all entries  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Authordown Project Subject Run Number Events StartTime EndTime Data
  1   Fri Nov 14 19:01:27 2014 Thomas BergauercommonAdministrative Procedures for Departure    Unknown

Wednesday:

* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt werden, was in der Zone war (also nicht im Counting room)

Merchandise-Bestätigung für die Anreise ist im attachment!

 

Anreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5855845

Abreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5863835

Attachment 1: Merchandise-2014.pdf
Attachment 2: ankunftsbestaetigung.pdf
  3   Fri Nov 14 19:47:25 2014 Thomas Bergauer Telefonnummern    Unknown

* CCC (zentraler Beschleuniger-Kontrollraum): 77500

* H6A Controlroom: 76755

* HEPHY-Handy: 16-2471 or +41 76 487 2471 from outside of CERN

* Office in Meyrin: 12-R11: 74592

 

Hostel-Zimmern:

* Bergi: 79326

* Benni: 60232

* Hao: 70408

 

Andere Wichtige Leute:

* Beam-Dame: Edda Gschwendner 16-5080

* NA Hallen Verantwortlicher: Michael Jeckel

Lookup Telefonnummern: http://phonebook.cern.ch

 
  5   Fri Nov 14 19:52:12 2014 Thomas Bergauer important web pages    Unknown

SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

general Information about the Beam line(s): http://sba.web.cern.ch/sba/

  6   Sat Nov 15 11:36:41 2014 Thomas BergauercommonChecklist for North Area access    Unknown

 

Checklist for North Area access: 

  • Dosimeter (http://dosimetry.web.cern.ch/en)
  • Helmet and safety shoes (http://gs-dep.web.cern.ch/en/content/stores_hours)
  • Access right to H6A control room (request via EDH): Control Room HNA-447 (0887-1-Q45). Activate access right on your CERN access card at one of the validation stations (https://espace.cern.ch/service-access-control/default.aspx)
  • For using CERN rental car, request "CERN vehicle driving license (V)" via EDH
  • Park in front of bldg. 890. Walk to North Hall (bldg. 887) through bldg. 907. Swipe dosimeter in front of electronic lock next to the entrance door. Turn left inside bldg. 887. Control room Q45 is on the left-hand side of the upper level. Swipe CERN access card in front of electronic lock.
  7   Sat Nov 15 11:37:19 2014 Thomas BergauerAIDAList of EUDET Telescope PCs in H6b    Unknown

 https://twiki.cern.ch/twiki/bin/view/CLIC/ClicPixelDataTakingCERNPS2014

  9   Sun Nov 16 14:22:51 2014 Thomas BergauerAIDAPC Configuration EUDET Telescope in H6b    Unknown

PC (gehört AIDA) in H6b control room:  ssh telescope@pcaidatb.cern.ch

 

 

  11   Mon Nov 17 19:23:57 2014 Thomas BergauerInfineonPI XY table initial position    Unknown

initial position of Infineon Stack (PI Micromove):
(guess center position by eye)

STRIPS IN HORIZONTAL DIRECTION

* vertical axis: M511.DD: Zero position 81.0mm / higher values correspond to lowering the table

* vertical axis: M521.DD: Zero position 96.0mm / higher values correspond to move the table to the table mounting

  29   Tue Nov 18 13:13:53 2014 Thomas BergauerInfineonhardware runinfineon_run001225508  Unknown

Infineon new stack - batch 4

single hit
 
HV=300V, total I = 4.2475 µA
 
strips horizontal
 
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
 
STOPPED by main User in H6B (18:11, 15:00)
 
Events: 225508
Next step: rearange modules vertically
 
  2   Fri Nov 14 19:22:40 2014 Martin Kurzcommonip addresses, portforwarding, wlan    Unknown

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.61.16 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.10 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 AIDA DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22)  SSH(9004)
192.168.0.15 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
       

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

  12   Mon Nov 17 22:03:02 2014 Martin KurzcommonDrucker    Unknown

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

  53   Thu Nov 20 10:22:17 2014 Markus FriedlBelle SVDcommon    Unknown
  1. Some VME errors occured over night
  2. Optical fiber changed
  3. Situation improved

 

  1. L3n hybrid could not be configured by I2C
  2. Plugged cable into the former FWDn slot
  3. Fully working

 

  92   Sat Nov 22 11:16:26 2014 Markus FriedlBelle SVDcooling    Unknown

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

  109   Sun Nov 23 09:49:00 2014 Markus FriedlBelle SVDcooling    Unknown

Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.

Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.

 

Attachment 1: temp_last_night.png
temp_last_night.png
  115   Sun Nov 23 15:07:54 2014 Markus FriedlBelle SVDcommon    Unknown

Geometry setup of FW/BW:

(all dimensions are in mm and refer to the sensor planes)

Attachment 1: fwbw_setup.png
fwbw_setup.png
  116   Sun Nov 23 15:09:53 2014 Markus FriedlBelle SVDPedestalRun00110000  Good

Initial pedestal run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side)

  117   Sun Nov 23 15:10:42 2014 Markus FriedlBelle SVDCalibrationRun00183400  Good

Initial calibration run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side)

  118   Sun Nov 23 15:13:37 2014 Markus FriedlBelle SVDHardwareRun00310060023.11.2014 14:07:2323.11.2014 16:51:27Good

Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

  119   Sun Nov 23 16:55:37 2014 Markus FriedlBelle SVDHardwareRun0046060023.11.2014 16:51:4923.11.2014 18:23:54Good

Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

  121   Sun Nov 23 18:26:54 2014 Markus FriedlBelle SVDHardwareRun0056060023.11.2014 18:24:3423.11.2014 Good

Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

  10   Sun Nov 16 21:37:56 2014 Hao YincommonAIM    Unknown

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

  13   Mon Nov 17 22:18:27 2014 Hao YinBelle SVDADC delay scan  Mon Nov 17 22:08:29 Unknown

L3-p: 18

L4-p: 36

L5-p: 33

L6-p: 39

 

L3-n: 18

L4-n: 36

L5-n: 36

L6-n: 35

  14   Mon Nov 17 22:21:41 2014 Hao Yin FIR run001 Mon Nov 17 22:08:29 CET 2014 Good

Excellent, brilliant run. 

  15   Mon Nov 17 22:21:50 2014 Hao Yin Bad APVs  Mon Nov 17 22:08:29 CET 2014 Unknown

List with bad APVs:


 

Crap:

 APV 5 L6-p Channel 23

 

Not working:

 L3-n APV 3

 

  16   Mon Nov 17 22:22:56 2014 Hao Yin PedestalRun_00100110000Mon Nov 17 22:22:41 CET 2014 Unknown

At room temperature.

 

  17   Mon Nov 17 22:28:05 2014 Hao Yin CalibrationRun001 Mon Nov 17 22:27:07 CET 2014 Unknown

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

  18   Mon Nov 17 22:28:07 2014 Hao Yin CalibrationRun001 Mon Nov 17 22:27:07 CET 2014 Unknown

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

  19   Mon Nov 17 22:28:09 2014 Hao Yin CalibrationRun001 Mon Nov 17 22:27:07 CET 2014 Unknown

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

  20   Mon Nov 17 23:04:57 2014 Hao YinBelle SVDPedestalRun_002 10338Mon Nov 17 23:03:03 CET 2014 Unknown

Pedestal run at room temperature.

6 subevents. Noise reference run.

Delay as latest run.

 

Reference run for bad strips.

  21   Tue Nov 18 01:03:18 2014 Hao YinBelle SVDRemapped FADC inputs  Tue Nov 18 01:03:32 CET 2014 Unknown

We moved the second cable to the third connector on the FADC to match DESY testbeam conditions. 

  22   Tue Nov 18 01:05:04 2014 Hao YinBelle SVDPedestalRun_003  Tue Nov 18 01:03:32 CET 2014 Unknown

New pedestal run after switching the connectors.

At room temperature 

  23   Tue Nov 18 09:45:59 2014 Hao Yin FIRRun_002002 Tue Nov 18 09:45:58 CET 2014 Unknown

New FIR run after reconecting to original setting. 

  24   Tue Nov 18 09:48:53 2014 Hao YinBelle SVDPedestalRun_004 10000Tue Nov 18 09:48:30 CET 2014 Unknown

At room temperature.

Old delay settings and FIRRun_002

 

  25   Tue Nov 18 09:51:11 2014 Hao Yin CalibrationRun_002  Tue Nov 18 09:50:24 CET 2014 Unknown

At room temperature

PedestalRun004 

Latest delay settings and FIRRun

  26   Tue Nov 18 10:12:25 2014 Hao YinBelle SVD6let PedestalRun_005 10000Tue Nov 18 10:11:45 CET 2014 Unknown

At room temperature

Latest delay, FIRRun002. 

Check for bad strips.

  27   Tue Nov 18 10:26:56 2014 Hao YinBelle SVDCalibrationRun_003  Tue Nov 18 10:26:52 CET 2014 Unknown

At room temperature

Latest delay and FIRRun 

  32   Tue Nov 18 18:45:01 2014 Hao YinBelle SVDTrigger Delay scan  Tue Nov 18 18:21:50 CET 2014 Unknown

At room temperature

First run was at: 23 (no track)

 

TimingRun_001:

Trigger delay: 26

 

TimingRun_002:

Trigger delay: 29

 

TimingRun_003:

Trigger delay: 32


 

TimingRun_004:

Trigger delay: 20

 
 

TimingRun_005:

Trigger delay: 17

 

TimingRun_005:

Trigger delay: 14
Trigger chip delay: 110

 

 

 

  33   Tue Nov 18 20:26:12 2014 Hao YinBelle SVDHardwareRun_001  Tue Nov 18 18:21:50 CET 2014 Unknown

At room temperature

Latest ADC scan and FIR run.

Latest CAL.

 

Position: 0.0, see elog entry.

  42   Wed Nov 19 20:04:53 2014 Hao YinBelle SVDPedestalRun_006    Unknown

Temperature: See attachment

FIRFilterRun_002

Layer 3-n side deactivated, because Hao broke it.

Attachment 1: Temp_19-11-14.PNG
Temp_19-11-14.PNG
  43   Wed Nov 19 20:07:05 2014 Hao YinBelle SVDHardwareRun_002    Unknown

Multi-6 cooled.

See latest Noise, and PedestalRun.

 

  46   Wed Nov 19 22:25:29 2014 Hao YinBelle SVDPedestalRun_008 [CheckLayout]    Unknown

cooled (temperature see attachment latest noise run),

latest Noise, FIR settings with the right layout mapping.

  47   Wed Nov 19 22:59:24 2014 Hao YinBelle SVDCalibrationRun_004    Crap

cooled (see last calibration run)

Latest noise, FIRfilter settings. 

 

Failed due to VME read timeout.

  48   Wed Nov 19 23:15:50 2014 Hao YinBelle SVDHardwareRun_003    Unknown

cooled, latest noise, cal, PedestalRun.

Rawmode

  49   Wed Nov 19 23:31:08 2014 Hao YinBelle SVDHardwareRun_004    Unknown

Same as HardwareRun_003 but with ZS.  

  50   Thu Nov 20 00:52:50 2014 Hao YinBelle SVDFIRRun_002    Unknown

cooled with new delay run

  51   Thu Nov 20 00:54:21 2014 Hao YinBelle SVDPedestalRun_008    Unknown

temp see attachment (von flo)
10000
latest fir filter (002)

  52   Thu Nov 20 00:55:14 2014 Hao YinBelle SVDHardwareRun_007    Unknown

temp cooled see attachment

last noise run(007)

FIRRun_002

PedestalRun_008

new cal run Raw, test with put fifo full flags

  58   Thu Nov 20 11:13:44 2014 Hao Yin HardwareRun_008008   Crap

cooled see attachment in FIRRun_003

PedestalRun_009

CalibrationRun_005

zerosuppressed

  60   Thu Nov 20 15:32:33 2014 Hao Yin HardwareRun010   Crap

same as hardware run 009

FIFO FULL ERROR starting at ~event 5000

  63   Thu Nov 20 16:13:18 2014 Hao YinBelle SVDHardwareRun011   Crap

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

 

 

FIFO FULL at  event ~27000

  66   Thu Nov 20 22:11:06 2014 Hao YinBelle SVDHardwareRun012   Good

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

  80   Fri Nov 21 19:05:27 2014 Hao YinBelle SVDFIRRun_004  Fri Nov 21 19:05:23 CET 2014 Unknown

New ADC delay scan. cooled, -25 temperature

 

  81   Fri Nov 21 19:10:09 2014 Hao YinBelle SVDCalibrationRun_006    Unknown

cooled, latest ADC delay scan and FIRRun. 

  83   Fri Nov 21 19:42:36 2014 Hao Yin HardwareRun_033    Good

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Attachment 1: Temp_21-11-14.PNG
Temp_21-11-14.PNG
  84   Fri Nov 21 22:08:32 2014 Hao Yin PedestalRun01310000  Unknown

correct mapping

cooled -25 °C

L3n deactivated

 

  94   Sat Nov 22 15:31:49 2014 Hao YinBelle SVDHardwareRun038437882014-11-22 15:18:40 Unknown

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

  105   Sun Nov 23 01:05:43 2014 Hao YinBelle SVDHardwareRun039200002014-11-22 15:18:40 Crap

Cooled down to -20

Bias voltage set to +-80V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

 

  106   Sun Nov 23 01:37:42 2014 Hao YinBelle SVDHardwareRun040200002014-11-23 01:37:00 Unknown

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

  110   Sun Nov 23 10:32:41 2014 Hao YinBelle SVDPedestalRun01610000  Unknown

Pedestal Run

room temperature (30C)

Bias scans planned

  111   Sun Nov 23 10:51:49 2014 Hao YinBelle SVDHardwareRun04276863  Unknown

Hardware Run +-40V Bias

Room Temperature

Pedestal 016

Zero Suppressed

Attachment 1: Temp_23-11-14.PNG
Temp_23-11-14.PNG
  4   Fri Nov 14 19:49:04 2014 Florian BuchsteinercommonBelle Setup    Unknown
Attachment 1: SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
  8   Sat Nov 15 12:41:50 2014 Benedikt WürknerBelle SVDDiscoveries during preliminary sensor tests    Unknown

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Attachment 1: weird_signal.png
weird_signal.png
Attachment 2: faulty-signal-l4_n.png
faulty-signal-l4_n.png
Attachment 3: faulty-signal_l4_n_2.png
faulty-signal_l4_n_2.png
  35   Tue Nov 18 20:42:18 2014 Benedikt WürknerBelle SVDCoordinates of the DUT    Unknown

We set the coordinates trying to put the beam in an area with well working APVs

Peak of course differs for n and p sensors due to their different pitch.

L4-6 n-side Peak around strip 180

L4&6 p-side mean value around strip 380

L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320

The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.

  54   Thu Nov 20 10:33:13 2014 Benedikt WürknerBelle SVDFIRRun and Delay Scan003   Unknown

 Cooled see appendix

with new layout (l3_n-side channels changed and reactivated).

Latest FIRRun

Attachment 1: Temp_19-11-14.PNG
Temp_19-11-14.PNG
  55   Thu Nov 20 10:39:11 2014 Benedikt WürknerBelle SVDPedestalRun_009    Unknown

cooled see appendix (FIRRun003)

MaxEvents 10000

 

  56   Thu Nov 20 10:39:13 2014 Benedikt WürknerBelle SVDPedestalRun_009    Unknown

cooled see appendix (FIRRun003)

MaxEvents 10000

 

  57   Thu Nov 20 10:41:54 2014 Benedikt WürknerBelle SVDCalibrationRun_005    Unknown

 cooled see appendix (FIRRun_003)

PedestalRun_009

  59   Thu Nov 20 11:14:19 2014 Benedikt Würkner HardwareRun_009009   Crap

 cooling see attachment of FIRRun003

Ped 009

Cal 005

Multi 6 raw mode

L5_n_side out of order

 

FIFO_FULL_ERROR starting at ~2000 events

  71   Fri Nov 21 15:02:28 2014 Benedikt WürknerBelle SVDHardwareRun0131433  Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

  72   Fri Nov 21 15:03:08 2014 Benedikt WürknerBelle SVDHardwareRun014989  Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

  73   Fri Nov 21 15:07:24 2014 Benedikt WürknerBelle SVDHardwareRun0191509482014-11-21 02:41:552014-11-21 10:11:02Unknown

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

  74   Fri Nov 21 15:10:19 2014 Benedikt Würkner HardwareRun15-22 (exept 19) none  Crap
  93   Sat Nov 22 11:37:16 2014 Benedikt WürknerBelle SVDHardwareRun0364503782014-11-22 1:00:002014-11-22 10:27:54Unknown

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Attachment 1: SPS_Testbeam-Temp.xlsx
Attachment 2: Screen_Shot_2014-11-22_at_12.41.44.png
Screen_Shot_2014-11-22_at_12.41.44.png
  112   Sun Nov 23 12:17:59 2014 Benedikt WürknerBelle SVDHardwareRun04420000  Unknown

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

  114   Sun Nov 23 12:55:47 2014 Benedikt WürknerBelle SVDHardwareRun04520000  Unknown

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

Entry is currently edited by Thomas Bergauer on 193.170.243.91    120   Sun Nov 23 17:51:44 2014 Benedikt WürknerBelle SVDHardwareRun04610000020:0620:36Unknown

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

  28   Tue Nov 18 12:35:32 2014 Axel KönigcommonInfineon (4 modules) TLU Settings    Unknown
  1.  VNC to 192.168.0.18
  2. In command line: cd C:\Users\telescope\eudaq\bin
  3. TLUControl.exe.exe -d 2 -a 11 - i RJ45

Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45

Dut Position (left to right):  11, 06, 05, 07

  30   Tue Nov 18 18:29:55 2014 Axel KönigInfineoncalibration runInfineon_run002   Unknown

Infineon_run002 is just a calibration run for the vertical positioned sensors. 

data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
  31   Tue Nov 18 18:33:31 2014 Axel KönigInfineonhardware runInfineon_run003300000  Unknown

Infineon new stack - batch 4

single hit

HV=300V, total I = 4.0044 µA

strips vertical

Table Position: H: 96mm V: 101mm

data file in L:\cern14\infineon\Infineon Run vert

config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg

 

--Stopped 18.11 / 20:20---

Reason: Enough events, adjusting new DUT position for next run

Events: 300000

  36   Tue Nov 18 23:04:34 2014 Axel KönigInfineonhardware runInfineon_run004400000  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0044 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
 
  37   Wed Nov 19 00:58:27 2014 Axel KönigInfineonhardware runInfineon_run00587000  Unknown

Infineon new stack - batch 4 

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000
  38   Wed Nov 19 09:26:39 2014 Axel KönigInfineonhardware runInfineon_run0061500  Unknown

Infineon new stack - batch 4

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 91mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr)
  39   Wed Nov 19 16:24:25 2014 Axel KönigcommonRunning EUDAQ    Unknown

Windows PC at Telescope:

0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start

1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's

2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat

3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.)

4.) configure

5.) start

x) Online monitor in preparation

Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC]

  40   Wed Nov 19 18:20:29 2014 Axel KönigInfineoncalibration runInfineon_run007_cal   Unknown
  44   Wed Nov 19 21:56:44 2014 Axel KönigInfineonhardware runInfineon_run008244167  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0758 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167
  45   Wed Nov 19 22:15:41 2014 Axel KönigInfineonhardware runInfineon_run0101498709  Unknown

Infineon new stack - batch 4 

 
single hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
EUDAQ data: Run951 and Run952
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped 20.11 / 09:35-- 
 
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
 
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer)
  61   Thu Nov 20 15:46:21 2014 Axel KönigInfineonhardware runInfineon_run012263470  Unknown

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = ? µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470
  62   Thu Nov 20 15:47:56 2014 Axel KönigInfineonhardware runInfineon_run011   Unknown

 Infineon new stack - batch 4 

 faulty!!!
  64   Thu Nov 20 17:16:56 2014 Axel Königcommonhow to run the EUDAQ offline monitor    Unknown

YOU need

1.) Folder EUDAQ OFFLINE Monitor

2.) ROOT

 

Starting: 

1.) open command line and chose the path where OfflineMonitor is

2.)Type -i "patch of raw file" -o test.root 100

3.) helpfile typing -h

  65   Thu Nov 20 18:15:48 2014 Axel KönigInfineonhardware runInfineon_run013_voltage51273  Unknown

Infineon new stack - batch 4 

single hit + eudaq
 
HV=100V, total I = 3.0326 µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
eudaq file: run000959.raw
 
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273
  67   Thu Nov 20 22:12:21 2014 Axel KönigcommonSPS Logbook / SPS Online Monitor    Unknown

Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325

 

Monitor:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

  68   Fri Nov 21 01:43:54 2014 Axel KönigAIDAcalibration runAIDA_run001_calibration   Unknown

Calibration run with AIDA DUT.

Single hit

  69   Fri Nov 21 11:10:08 2014 Axel KönigAIDAhardware runAIDA_run002211362  Unknown

AIDA

multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
 
EUDAQ File: Run000962, Run000963, Run000964
 
config: L:\cern14\AIDA
data: L:\cern14\AIDA
 
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000
  70   Fri Nov 21 12:14:46 2014 Axel KönigAIDAhardware runAIDA_run00320617  Unknown

AIDA

 

single hit

Voltage=100V, I=5.4240uA

(new table calibration): V:66mm, H:74mm

EUDAQ file:  Run000965

config: L:\cern14\AIDA

data: L:\cern14\AIDA

 

--Stopped 21.11 / 12:12--

DaqEvents: 20617 (-600 ped)

EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) 

  75   Fri Nov 21 15:37:30 2014 Axel KönigAIDAhardware runAIDA_run0047057  Unknown

AIDA

 

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

 

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000977

--Stopped 21.11 / 12:12--

DaqEvents: 7057 (-600 ped)

EUDAQ EVENTS: 4658 (less than Daq) 

  76   Fri Nov 21 18:20:47 2014 Axel KönigAIDAhardware runAIDA_run00520045  Unknown

AIDA

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000979

--Stopped 21.11 / 12:12--

DaqEvents: 20045 (-600 ped)

EUDAQ EVENTS: ~18k

  77   Fri Nov 21 18:21:45 2014 Axel KönigAIDAhardware runAIDA_run006~1k  Unknown

 verwerfen!

  78   Fri Nov 21 18:23:05 2014 Axel KönigcommonNew Table Calibration    Unknown

 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.

  79   Fri Nov 21 18:35:17 2014 Axel KönigAIDAImportant: Dockbox Inverter!    Unknown

Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.

Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 

Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 

  82   Fri Nov 21 19:25:57 2014 Axel KönigAIDAhardware runAIDA_run00726770  Unknown

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

  85   Fri Nov 21 23:33:54 2014 Axel KönigAIDAhardware run (PC crashed)AIDA_run008---  Unknown

22:00 SVD3 PC crashed!!! data will be collected. 

  86   Fri Nov 21 23:34:36 2014 Axel KönigAIDAhardware runAIDA_run00932902  Unknown

 

AIDA

multi hit

Voltage=100V, I=5.2190uA

(new table calibration): V:71mm, H:100mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 32902 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
  87   Fri Nov 21 23:40:10 2014 Axel KönigAIDAhardware runAIDA_run01026329  Unknown

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
  88   Sat Nov 22 00:11:36 2014 Axel KönigAIDAhardware runAIDA_run01124916  Unknown

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

  89   Sat Nov 22 00:58:04 2014 Axel KönigAIDAhardware runAIDA_run012276006  Unknown

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

  90   Sat Nov 22 07:56:33 2014 Axel KönigAIDAhardware runAIDA_run01355629  Unknown

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:45mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000990

DaqEvents: 55629 (-600 ped)

EUDAQ EVENTS: 55003 

 
  91   Sat Nov 22 10:20:07 2014 Axel KönigAIDAcalibration runAIDA_calibration   Unknown

Calibration run AIDA_calibration 

L:\cern14\AIDA

  95   Sat Nov 22 16:04:05 2014 Axel KönigInfineonInfineon old calibrationInfineon_old_calibration   Unknown

Calibration run 

L:\cern14\infineon_old

  96   Sat Nov 22 16:43:18 2014 Axel Königcommontable, telescope and dut geometry     Unknown

geometry files

Attachment 1: geometry_table.pdf
Attachment 2: geometry_DUT.pdf
Attachment 3: geometry_infineon_batch4.pdf
Attachment 4: geometry_infineon_old.pdf
  97   Sat Nov 22 16:53:39 2014 Axel KönigInfineonInfineon oldInfineon_old_run00155000   Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  98   Sat Nov 22 17:00:43 2014 Axel KönigInfineonInfineon olddamaged strixel sensors, strange IV behaviour   Unknown

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

  99   Sat Nov 22 18:08:03 2014 Axel KönigInfineonhardware runInfineon_old_run00255000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  100   Sat Nov 22 19:29:40 2014 Axel KönigAIDADUT Position    Unknown
Attachment 1: AIDA_DUT_Position.JPG
AIDA_DUT_Position.JPG
  101   Sun Nov 23 00:20:41 2014 Axel KönigInfineonhardware runInfineon_old_run00330000  Unknown

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:?, H:?

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000994

DaqEvents: 30000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  102   Sun Nov 23 00:24:15 2014 Axel KönigInfineonhardware runInfineon_old_run004168725  Unknown

Infineon old

multi hit

Voltage=300V, I=10.6529uA

(new table calibration): V:81, H:88

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000996

DaqEvents: 168725 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

  103   Sun Nov 23 00:51:07 2014 Axel KönigInfineonhardware runInfineon_old_run00526569  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4609uA

(new table calibration): V:75, H:94.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000997

DaqEvents: 26569 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

 
  107   Sun Nov 23 09:32:48 2014 Axel KönigInfineonhardware runInfineon_old_run00763913  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  108   Sun Nov 23 09:36:27 2014 Axel KönigInfineonhardware runInfineon_old_run006526562  Unknown

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

  113   Sun Nov 23 12:39:45 2014 Axel KönigcommonPMT's of EUDET (Igor Rubinsky)    Unknown

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

ELOG V3.1.5-fc6679b