ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
Text |
|
37
|
Fri Oct 19 00:45:52 2012 |
Markus Friedl | MicronOrigami_gross | run | run016 | 11855 | 19.10.2012 00:24:05 | 19.10.2012 00:48:24 | Crap |
Belle Stack 4: 2 DSSD -z, Origami
#3, #1, wedge new #2 |
|
35
|
Wed Oct 17 21:30:39 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal008 | 83800 | 17.10.2012 17:15:13 | 17.10.2012 18:08:11 | Good | Internal calibration for "stealth
parasitic" mode Belle stack; taken without
beam |
|
33
|
Wed Oct 17 05:16:22 2012 |
Christian Irmler | MicronOrigami_gross | run | run015 | 54005 | 17.10.2012 05:10:06 | 17.10.2012 07:27:20 | Unknown | Origami Stack 2: Origami #4, #3, Wedge
new1, old
HV = +-50V |
|
31
|
Tue Oct 16 23:35:28 2012 |
Christian Irmler | MicronOrigami_gross | run | run014 | 150k | 16.10.2012 23:32:24 | 17.10.2012 04:59:02 | Unknown | Same as run011, but now with +- 50V bias
voltage.
Origami Stack 2: Origami #4, #3, |
|
29
|
Tue Oct 16 22:19:21 2012 |
Christian Irmler | MicronOrigami_gross | cal | cal007 | 83800 | 16.10.2012 20:25:17 | 16.10.2012 21:12:01 | Unknown | Origami Stack 2: Origami #4, #3, Wedge
new1, old
HV = +-50V, Ibias=12.3µA |
|
28
|
Tue Oct 16 13:59:46 2012 |
Christian Irmler | MicronOrigami_gross | run | run013 | 150k | 16.10.2012 13:43:05 | 16.10.2012 20:21:04 | Unknown | Origami Stack 2: Origami #4, #3, Wedge
new1, old
HV = +-50V |
|
27
|
Tue Oct 16 11:23:43 2012 |
Christian Irmler | MicronOrigami_gross | run | run012 | 20k | 16.10.2012 11:16:01 | 16.10.2012 12:27:03 | Unknown | Origami Stack 2a: Origami #4, Wedge new1
reading out all 6 APV of p-side
HV = +-40V, Ibias=10.4µA |
|
26
|
Tue Oct 16 11:07:17 2012 |
Christian Irmler | MicronOrigami_gross | cal | cal006 | 83800 | 16.10.2012 10:30:34 | 16.10.2012 11:00:51 | Unknown | Origami Stack 2a: Origami #4, Wedge new1
reading out all 6 APV of p-side
HV = +-40V, Ibias=5.12µA |
|
25
|
Tue Oct 16 05:24:21 2012 |
Christian Irmler | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run011 | 150k | 16.10.2012 05:19:28 | 16.10.2012 09:59:24 | Crap | ATTENTION: Bias voltage was +-100 V instead
of +- 50 V
Origami Stack 2: Origami #4, #3, |
|
24
|
Mon Oct 15 23:26:52 2012 |
Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run010 | 158k | 15.10.2012 23:10:40 | 16.10.2012 05:05:35 | Crap | ATTENTION: Bias voltage was +-100 V instead
of +- 50 V
Same as run009. |
|
32
|
Wed Oct 17 01:21:50 2012 |
Marko Dragicevic | Infineon | run | run009 | 150k | 15.10.2012 08:20:15 | 15.10.2012 11:01:11 | Unknown | This run was not recorded in original
sequence in the ELOG!!!
|
|
19
|
Mon Oct 15 00:08:26 2012 |
Marko Dragicevic | Infineon | run | run008 | 339075 | 15.10.2012 01:49:33 | 15.10.2012 08:04:24 | Unknown | Infineon Stack Version
2 (no height information, BabyStrips vertical |
|
23
|
Mon Oct 15 22:13:28 2012 |
Marko Dragicevic | MicronOrigami_gross | cal ATTENTION: wrong bias voltage | cal005 | 83800 | 15.10.2012 22:16:26 | 15.10.2012 23:07:37 | Unknown | ATTENTION: Bias voltage was +-100 V instead
of +- 50 V
Origami Stack 2: Origami #4, #3, |
|
22
|
Mon Oct 15 19:40:03 2012 |
Marko Dragicevic | MicronOrigami_gross | run ATTENTION: wrong bias voltage | run009 | 31650 | 15.10.2012 19:28:30 | 15.10.2012 22:08:31 | Crap | ATTENTION! Bias voltage was +-100 V instead
of +-50 V
Origami Stack 2: Origami #4, #3, |
|
17
|
Sun Oct 14 20:12:14 2012 |
Marko Dragicevic | Infineon | run | run007 | 110k | 14.10.2012 20:07:12 | 14.10.2012 21:04:12 | Unknown | Infineon Stack Version 1 (with height information,
BabyStrips horizontal Strixel vertical)
HV = 300V I=3uA |
|
18
|
Sun Oct 14 23:01:11 2012 |
Marko Dragicevic | Infineon | cal | cal004 | 83800 | 14.10.2012 21:44:00 | 14.10.2012 21:03:00 | Unknown | Infineon Stack Version 1 (with height information,
BabyStrips horizontal Strixel vertical)
HV = 300V I=3.1 uA |
|
15
|
Sun Oct 14 08:25:10 2012 |
Manfred Valentan | MicronBaby | cal | cal003 | 83800 | 14.10.2012 08:21:46 | 14.10.2012 08:51:58 | Unknown | Micron baby intermediate stack
HV = -100 V
I = 6.9 uA |
|
14
|
Sun Oct 14 02:02:39 2012 |
Manfred Valentan | MicronBaby | run | run005 | 300k | 14.10.2012 02:00:08 | 14.10.2012 08:17:02 | Unknown | Micron baby intermediate stack
HV = -100V I=6.3uA
beam on |
|
11
|
Sat Oct 13 23:01:54 2012 |
Markus Friedl | MicronOrigami_gross | run with Belle stack 3 | run004 | 30k | 13.10.2012 21:41:34 | 13.10.2012 22:57:48 | Unknown | Belle stack 3, other position (CE)
Position of xy table: |
|
12
|
Sat Oct 13 23:04:22 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal002 | 83800 | 13.10.2012 23:03:18 | 13.10.2012 22:57:48 | Unknown | Belle stack 3 (2-DSSD, Micron new, Micron
old)
HV = +-50V I=10.5A |
|