ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
StartTime |
EndTime |
Data |
26
|
Tue Oct 16 11:07:17 2012 |
Christian Irmler | MicronOrigami_gross | cal | cal006 | 83800 | 16.10.2012 10:30:34 | 16.10.2012 11:00:51 | Unknown | Origami Stack 2a: Origami #4, Wedge new1
reading out all 6 APV of p-side
HV = +-40V, Ibias=5.12µA
no beam
no cooling |
27
|
Tue Oct 16 11:23:43 2012 |
Christian Irmler | MicronOrigami_gross | run | run012 | 20k | 16.10.2012 11:16:01 | 16.10.2012 12:27:03 | Unknown | Origami Stack 2a: Origami #4, Wedge new1
reading out all 6 APV of p-side
HV = +-40V, Ibias=10.4µA
Origami 3 and Wedge old are still installed in the box, but not read out --> disconnected
beam:
p-side: centered between APV 4&5
n-side: centered between APV 2&3
--> upper left corner of Origami and wedge module --> we hit the APV chips and / or the PA0 of the Origami module
no cooling
Temperatur sensors:
- T11: Origami #4 in
- T12: Origami #4 out
- T13: Origami #3 in (wrong values!)
- T14: Origami #3 out
- T15: Wedge new 1 out
- T16: Wedge old out
- T17: Wedge new 1 cooling block
- T18: Wedge old cooling block
|
Attachment 1: belle_2a_temperatures.jpg
| |
28
|
Tue Oct 16 13:59:46 2012 |
Christian Irmler | MicronOrigami_gross | run | run013 | 150k | 16.10.2012 13:43:05 | 16.10.2012 20:21:04 | Unknown | Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-50V
Ibias=5.2µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#3 -> left side of sensor -> wide side of wedge sensors
Position of xy table:
x = 83, y = -31
Temperatur sensors:
- T11: Origami #4 in
- T12: Origami #4 out
- T13: Origami #3 in (wrong values!)
- T14: Origami #3 out
- T15: Wedge new 1 out
- T16: Wedge old out
- T17: Wedge new 1 cooling block
- T18: Wedge old cooling block
|
Attachment 1: belle_2_temperatures.jpg
| |
29
|
Tue Oct 16 22:19:21 2012 |
Christian Irmler | MicronOrigami_gross | cal | cal007 | 83800 | 16.10.2012 20:25:17 | 16.10.2012 21:12:01 | Unknown | Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-50V, Ibias=12.3µA
Position: verticallbtween APV 1&2 of 6, left side of sensor,
wide side of wedge sensors
calibration for run013
Temperatures @ 21:00:
T11: -32 degC
T12: -33 degC
T13: -16 degC (obviously wrong value)
T14: -35 degC
T15: -18 degC
T16: -17 degC
T17: -15 degC
T18: -15 degC |
30
|
Tue Oct 16 23:03:09 2012 |
Markus Friedl | common | Sozialisierung | | | | | Unknown | So steuert man einen Testbeam!
|
Attachment 1: IMAG2041.jpg
| |
31
|
Tue Oct 16 23:35:28 2012 |
Christian Irmler | MicronOrigami_gross | run | run014 | 150k | 16.10.2012 23:32:24 | 17.10.2012 04:59:02 | Unknown | Same as run011, but now with +- 50V bias voltage.
Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-10V
Ibias=4.83µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#1 -> right side of sensor -> small side of wedge sensors
Position of xy table:
x = 23, y = -31
Temperatur sensors:
- T11: Origami #4 in
- T12: Origami #4 out
- T13: Origami #3 in (wrong values!)
- T14: Origami #3 out
- T15: Wedge new 1 out
- T16: Wedge old out
- T17: Wedge new 1 cooling block
- T18: Wedge old cooling block
|
Attachment 1: run014_temperatures.jpg
| |
32
|
Wed Oct 17 01:21:50 2012 |
Marko Dragicevic | Infineon | run | run009 | 150k | 15.10.2012 08:20:15 | 15.10.2012 11:01:11 | Unknown | This run was not recorded in original sequence in the ELOG!!!
Infineon Stack Version 2 (no height information, BabyStrips vertical Strixel vertical)
HV = 300V I=4uA
beam on
Final DESY position (center of vertical beam profile)
Module position: 15 / 3 -- hitting lower part of baby and bottom strixels
07_baby |
0,0 |
APV1 lower, APV2 upper |
Strixel 2 |
20,8 |
Hybrid1/APV1 top-left, Hybrid1/APV2 top right, Hybrid2/APV1 bottom left, Hybrid2/APV2 bottom right |
Strixel 1 |
39,4 |
Hybrid1/APV1 top-left, Hybrid1/APV2 top right, Hybrid2/APV1 bottom left, Hybrid2/APV2 bottom right |
12_baby |
60,6 |
APV1 lower, APV2 upper |
|
|
33
|
Wed Oct 17 05:16:22 2012 |
Christian Irmler | MicronOrigami_gross | run | run015 | 54005 | 17.10.2012 05:10:06 | 17.10.2012 07:27:20 | Unknown | Origami Stack 2: Origami #4, #3, Wedge new1, old
HV = +-50V
Ibias=4.43µA
beam position:
vertical: between APV 1&2 (of 6)
horizontal: centered on APV#2 -> center of measureable area
Position of xy table:
x = 53, y = -31
Temperatur sensors:
- T11: Origami #4 in
- T12: Origami #4 out
- T13: Origami #3 in (wrong values!)
- T14: Origami #3 out
- T15: Wedge new 1 out
- T16: Wedge old out
- T17: Wedge new 1 cooling block
- T18: Wedge old cooling block
CO2 was empty @ 6 am. |
Attachment 1: run015_temperatures.JPG
| |
36
|
Thu Oct 18 09:14:07 2012 |
Manfred Valentan | common | Fahrt nach Mol | | | | | Unknown | Liebe Kollegen,
wir brechen. auf. Wünscht uns Glück! |
55
|
Tue Oct 23 16:06:09 2012 |
Markus Friedl | MicronOrigami_gross | run | run026 | 102124 | 23.10.2012 16:04:47 | 23.10.2012 23:04:56 | Unknown | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-10V, Ibias=36uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
SPS Status during whole run: Still problems with North Area steering. means that beam position was not stable. |
|
56
|
Tue Oct 23 23:12:03 2012 |
Thomas Bergauer | MicronOrigami_gross | run | run027 | 220847 | 23.10.2012 23:10:14 | 24.10.2012 08:19:51 | Unknown | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-5V, Ibias=23.5uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
SPS Status during whole run: Still problems with North Area steering. means that beam position was not stable. |
57
|
Wed Oct 24 08:25:04 2012 |
Thomas Bergauer | MicronOrigami_gross | cal | cal027 | 83800 | 24.10.2012 08:22:25 | 24.10.2012 09:10:19 | Unknown | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-5V, Ibias=23.5uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1 |
58
|
Wed Oct 24 09:51:41 2012 |
Thomas Bergauer | MicronOrigami_gross | cal | cal028 | 83800 | 24.10.2012 09:50:53 | 24.10.2012 10:39:43 | Unknown | Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-2.5V, Ibias=14.5uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1 |
59
|
Wed Oct 24 17:24:40 2012 |
Thomas Bergauer | MicronOrigami_gross | run ohne Strom ;-( | run028 | | | | Unknown |
Belle Stack 4: 2 DSSD -z, Origami #3, #1, wedge new #2
HV = +-2.5V, Ibias=14.5uA
Position: APVs #2, 7, 11, 15 | # 17/18, 21, 25, 29
= p: 2DSSD #2, Origami3 #3, Origami1 #3, wedgenew #3
= n: 2DSSD #1/2, Origami3 #1, Origami1 #1, wedgenew #1
NO DATATAKING BECAUSE OF POWER FAILURE AT NIM CRATE (counter finster, warum?). Georg schaut sich das an, sobald in der zone access ist.
Auch AnnekathrinPC ist nicht erreichbar.
|
66
|
Sun Oct 28 08:37:53 2012 |
Christian Irmler | MicronOrigami_gross | run | run033 | 66937 | 28.10.2012 08:33:42 | 28.10.2012 14:10:43 | Unknown | Belle stack 2 after gamma irradiation
HV = +50V -50V
I = 101 uA
CO2 cooling
hitting APV2 (n side) = center of wedge sensor
Temperatur sensors:
- T11: Origami #4 in
- T12: Origami #4 out
- T13: Origami #3 in (still wrong values!)
- T14: Origami #3 out
- T15: Wedge new 1 out
- T16: Wedge old out
- T17: Wedge new 1 cooling block
- T18: Wedge old cooling block
|
Attachment 1: temp_run33.JPG
| |
Attachment 2: temp_run33_2.JPG
| |
70
|
Mon Oct 29 04:02:16 2012 |
Manfred Valentan | MicronBaby | run | run036 | 296294 | 29.10.2012 03:53:33 | 29.10.2012 11:05:35 | Unknown | Micron Baby stack 2 after irradiation (intermediate strips)
HV = -100 V
I = 36 uA
DESY table shifted by 2.5mm (beam down) after beam profile was changed (to get higher intensity)
beam hitting higher APVs
Stopped when long beam off period was announced |
74
|
Mon Oct 29 23:13:52 2012 |
Markus Friedl | HPK_baby | run | run038 | 476500 | 29.10.2012 23:13:05 | 30.10.2012 10:22:54 | Unknown | HPK baby stack after irradiation with partial cooling (HPK neutron & HPK neutron/gamma)
HV = +75 V -75V
I = 176A
positioned centered on p and n
Temp sensors configuration:
11 HPK Neutron n in
12 HPK Neutron n -> p
13 ----
14 HPK Neutron p -> Gamma p
15 Gamma p -> n
16 Neutron Gamma n out
Perfect cooling curve :-)
|
76
|
Tue Oct 30 11:05:32 2012 |
Markus Friedl | HPK_baby | run | run039 | 150k | 30.10.2012 11:03:19 | 30.10.2012 14:57:57 | Unknown | HPK baby stack after irradiation - no cooling
I = 420A and growing (warming up)
positioned centered on p and n
|
77
|
Tue Oct 30 17:24:01 2012 |
Markus Friedl | MicronOrigami_gross | cal | cal040 | 83800 | 30.10.2012 17:20:28 | 30.10.2012 17:54:09 | Unknown | Cooling for 2DSSD established after some struggle.
2DSSD fully read out with cooling
HV= +40 V -40 V I = 2 uA
Beam position: none
Positions of thermal sensors:
11 Kapillare Anfang
12 Kapillare Ende
13 ---
14 unmittelbar nach Kapillare
15 Origami in
16 Origami out
17 Origami -z
18 Origami CE
Strip order:
n-Seite: rechts (Salev) nach links (Jura)
p-Seite: oben nach unten
APV chips with lower noise:
-z ce
p-side #5 #10 (= pos 4)
n-side #13 (= pos1) #19 (= pos 3)
|
78
|
Tue Oct 30 18:35:51 2012 |
Christian Irmler | MicronOrigami_gross | run | run040 | 100k | 30.10.2012 18:23:21 | 30.10.2012 21:55:53 | Unknown | Cooling for 2DSSD established after some struggle.
2DSSD fully read out with cooling
HV= +40 V -40 V I = 2.1 uA
Beam position:
Origami -z
p-side: APV #5
n-side: APV #13 (= pos.1 of -z)
Positions of thermal sensors:
11 Kapillare Anfang
12 Kapillare Ende
13 ---
14 unmittelbar nach Kapillare
15 Origami in
16 Origami out
17 Origami -z
18 Origami CE
Strip order:
n-Seite: rechts (Salev) nach links (Jura)
p-Seite: oben nach unten
APV chips with lower noise:
-z ce
p-side #5 #10 (= pos 4)
n-side #13 (= pos1) #19 (= pos 3) |
Attachment 1: temperatures_run040.jpg
| |
|