Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS June 2008, all entries  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTimedown
  18   Sat May 31 17:36:14 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup)run271810000031.05.2008 16:21:5731.05.2008 21:08:32
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=+2 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12 (now for real)
telescope: zero supressed, new firmware

- long break in the middle due to power outage after thunderstorm

horizontal position ("target") = +2.0mm - after we decided to scan the whole area in 3 steps
this is RIGHT position

all 3 positions are:
RIGHT: +2.00 mm    <--- this run
MID:   -2.75 mm
LEFT:  -7.50 mm
  17   Sat May 31 17:32:35 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) run2717649031.05.2008 15:57:5831.05.2008 16:09:21
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12 (now for real)
telescope: zero supressed, new firmware

trigger is now correct (9 x 9 mm2 window)
horizontal position ("target") = 0.0mm
  16   Sat May 31 17:29:40 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup)run27162000031.05.2008 14:59:2631.05.2008 15:56:23
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: zero supressed, new firmware

in fact, trigger was set to coincidence of ALL FOUR scintillators, hence only (less than) 4 x 4 mm2 window !!!
horizontal position ("target") = 0.0mm
  14   Fri May 30 19:42:13 2008 stephan hänselSiLCAPVDAQ onlyrun00015180330.05.2008 19:38:0430.05.2008 22:54:59
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12
no telescope

terminated after 51803 events due to beam drop out @ 22.00h
  57   Tue Jun 3 11:03:27 2008 Thomas Bergauer telescope alignment runrun283038972008-06-03 10:52:16.7832008-06-03 10:58:52.790
telescope run with reduced beam intensity (BEND4=-600A instead of -620A and BEND7=-605A instead of -615A)
Attachment 1: beam_profile_with_modified_BEND4and7.png
beam_profile_with_modified_BEND4and7.png
Attachment 2: hit_correlations.png
hit_correlations.png
  27   Sun Jun 1 15:52:03 2008 Eudet TelescopeSiLCTelescope Pedestal Runrun273812471.6.2008. 15:501.6.2008. 15:58
Telescope Pedestal Run
no DUTs!
no Beam!
Config File: test5boards.conf
  66   Tue Jun 3 18:17:47 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup)run283847815903.06.2008 18:38:0704.06.2008 10:41:51
SiLC beam test - CERN SPS June 2008
HV=100V, xy "telescope"
8 modules, 40MHz, 6 samples, position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


this is a run where modules 0,2,4,6 are in normal position, while modules 1,3,5,7 are rotated by 90 deg
(counterclockwise as seen by the beam) and flipped (back<->forth) in order to achieve the minimum spacing
(~10.3mm) between "corresponding" x and y planes.
  65   Tue Jun 3 16:53:20 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28372000003.06.2008 16:49:4003.06.2008 17:26:49
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 0 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_00.gif
drehteller_rot_00.gif
Attachment 2: drehteller_rot.cdr
  64   Tue Jun 3 16:14:26 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28361000003.06.2008 16:13:1803.06.2008 16:33:20
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 60 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask

Please note that there are 8 modules read out in this run, but the last one (#7) is placed outside the beam and
hence does not provide any meaningful data.
Attachment 1: drehteller_rot_60.gif
drehteller_rot_60.gif
  63   Tue Jun 3 15:39:57 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28351000003.06.2008 15:36:4703.06.2008 15:55:34
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 50 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_50.gif
drehteller_rot_50.gif
  62   Tue Jun 3 14:59:14 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28341000003.06.2008 14:56:3203.06.2008 15:15:37
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 40 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_40.gif
drehteller_rot_40.gif
  61   Tue Jun 3 14:12:02 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28331000003.06.2008 14:10:4003.06.2008 14:29:26
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 30 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_30.gif
drehteller_rot_30.gif
  60   Tue Jun 3 13:28:15 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28321000003.06.2008 13:24:0703.06.2008 13:53:18
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 20 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_20.gif
drehteller_rot_20.gif
  58   Tue Jun 3 12:32:51 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** angle-scan ***run28311000003.06.2008 12:31:4203.06.2008 13:19:36
SiLC beam test - CERN SPS June 2008
Angle scan,  HV=100V, alpha = 10 degrees
8 modules, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

Angle scan with pattern mask
Attachment 1: drehteller_rot_10.gif
drehteller_rot_10.gif
  56   Tue Jun 3 10:58:54 2008 Markus FriedlBELLEAPVDAQ onlyped0071000003.06.2008 10:53:0403.06.2008 10:58:47
SiLC beam test - CERN SPS June 2008
4 Belle modules, 40MHz, HV=80V, 6 samples
beam on (lower intensity)
  55   Tue Jun 3 09:57:17 2008 Markus FriedlBELLEAPVDAQ onlyrun000710500003.06.2008 09:40:1803.06.2008 10:12:48
SiLC beam test - CERN SPS June 2008 - HIT MODE
4 Belle modules, 40MHz, HV=80V, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12
no telescope


Flex_Module has only 1 working APV - control bonds suffered during transportation

Position is approximately similar to KEK Nov 2007, however it appears like JP_module is flipped (up-down) w.r.t.
to other modules

RETRY after software bugfix - apparently works
  54   Tue Jun 3 09:27:27 2008 Markus FriedlBELLEAPVDAQ onlyrun00062392903.06.2008 09:26:1603.06.2008 09:34:22
SiLC beam test - CERN SPS June 2008 - HIT MODE
4 Belle modules, 40MHz, HV=80V, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


Flex_Module has only 1 working APV - control bonds suffered during transportation

Position is approximately similar to KEK Nov 2007, however it appears like JP_module is flipped (up-down) w.r.t.
to other modules

RETRY

STUCK again after some time - now adding veto clear in error handling routine
  53   Tue Jun 3 09:12:42 2008 Markus FriedlBELLEAPVDAQ onlyrun00054502003.06.2008 09:11:3003.06.2008 09:24:42
SiLC beam test - CERN SPS June 2008 - HIT MODE
4 Belle modules, 40MHz, HV=80V, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


Flex_Module has only 1 working APV - control bonds suffered during transportation

Position is approximately similar to KEK Nov 2007, however it appears like JP_module is flipped (up-down) w.r.t.
to other modules

SAME AS PREVIOUS, BUT 0-SUP WITHOUT TELESCOPE


stuck after 45020 events with the repeated message  
 ***WARNING*** FIFO3 empty, FADC 0. Event discarded, reset sent.
to be investigated.
  52   Tue Jun 3 02:38:21 2008 Markus FriedlBELLEAPVDAQ + telescope (0-sup)run282910500003.06.2008 02:29:5103.06.2008 09:08:58
SiLC beam test - CERN SPS June 2008
4 Belle modules, 40MHz, HV=80V, 6 samples
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


Flex_Module has only 1 working APV - control bonds suffered during transportation

Position is approximately similar to KEK Nov 2007, however it appears like JP_module is flipped (up-down) w.r.t.
to other modules
  50   Tue Jun 3 00:20:06 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28281000002.06.2008 23:55:0603.06.2008 00:18:56
SiLC beam test - CERN SPS June 2008
HV scan,  HV=200V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  49   Mon Jun 2 23:34:29 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28271000002.06.2008 23:33:4002.06.2008 23:52:04
SiLC beam test - CERN SPS June 2008
HV scan,  HV=150V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  48   Mon Jun 2 23:14:58 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28261000002.06.2008 23:14:1902.06.2008 23:31:29
SiLC beam test - CERN SPS June 2008
HV scan,  HV=120V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  47   Mon Jun 2 22:55:49 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28251000002.06.2008 22:55:0302.06.2008 23:12:09
SiLC beam test - CERN SPS June 2008
HV scan,  HV=90V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  46   Mon Jun 2 22:37:13 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28241000002.06.2008 22:36:3702.06.2008 22:53:15
SiLC beam test - CERN SPS June 2008
HV scan,  HV=80V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  45   Mon Jun 2 22:13:17 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28231000002.06.2008 22:12:4402.06.2008 22:34:49
SiLC beam test - CERN SPS June 2008
HV scan,  HV=70V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  44   Mon Jun 2 21:54:34 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28221000002.06.2008 21:53:3702.06.2008 22:10:53
SiLC beam test - CERN SPS June 2008
HV scan,  HV=60V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  43   Mon Jun 2 21:37:10 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run28211000002.06.2008 21:32:5702.06.2008 21:51:55
SiLC beam test - CERN SPS June 2008
HV scan,  HV=50V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

re-try after several hours of beam down


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  42   Mon Jun 2 16:01:10 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run2792453602.06.2008 16:00:0902.06.2008 16:19:42
SiLC beam test - CERN SPS June 2008
HV scan,  HV=50V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware

stopped after beam problem


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  41   Mon Jun 2 15:41:20 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run27911000002.06.2008 15:40:2002.06.2008 15:58:16
SiLC beam test - CERN SPS June 2008
HV scan,  HV=40V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  40   Mon Jun 2 15:21:53 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run27901000002.06.2008 15:20:4402.06.2008 15:38:04
SiLC beam test - CERN SPS June 2008
HV scan,  HV=30V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  38   Mon Jun 2 14:55:38 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run27891000002.06.2008 14:54:3302.06.2008 15:19:12
SiLC beam test - CERN SPS June 2008
HV scan,  HV=20V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  37   Mon Jun 2 14:32:40 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run27881000002.06.2008 14:31:1502.06.2008 14:51:55
SiLC beam test - CERN SPS June 2008
HV scan,  HV=10V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: 0sup., new firmware


HV scan after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  36   Mon Jun 2 13:19:10 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup) *** HV-scan ***run27873000002.06.2008 13:15:0402.06.2008 14:27:57
SiLC beam test - CERN SPS June 2008
HV scan,  HV=100V
8 modules, modules rearranged, 40MHz, 6 samples, hor position centered
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12


Reference run with nominal HV after re-arranging the modules:

               JURA
          | | |
          | | | | |
beam ---->| | | | | | | |
                | | | | |
                    | | |
          0 1 2 3 4 5 6 7
               SALEVE
  35   Sun Jun 1 23:46:33 2008 Markus FriedlSiLCAPVDAQ + telescope (raw)run2758 - run27833487301.06.2008 23:44:5702.06.2008 10:08:46
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=+2.0 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: raw, new firmware

last raw run in RIGHT position
  28   Sun Jun 1 16:06:42 2008 Markus FriedlSiLCAPVDAQ + telescope (raw)run2741 - run27572200001.06.2008 16:02:5601.06.2008 22:02:34
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-2.75 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: raw, new firmware

right from the start: no beam...
  22   Sun Jun 1 08:06:57 2008 stephan hänselSiLCAPVDAQ + telescope (raw)run2721-27372200001.06.2008 - 08:01:5301.06.2008 - 14:19:13
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: raw, new firmware

horizontal position ("target") = -7.5mm
this is LEFT position
  33   Sun Jun 1 23:23:16 2008 Markus FriedlSiLCAPVDAQ only (0-sup)run000410000001.06.2008 23:21:1201.06.2008 23:41:09
SiLC beam test - CERN SPS June 2008 - HIT MODE
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=+2 mm
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12 (manually)
no telescope

This is RIGHT position
APVDAQ runs in HIT MODE (=0-suppressed)
acquisition rate ~430 Hz during spill (TLU says ~86 Hz)
  32   Sun Jun 1 23:20:10 2008 Markus FriedlSiLCAPVDAQ onlyped0041000001.06.2008 23:16:5201.06.2008 23:19:59
SiLC beam test - CERN SPS June 2008 - PEDESTAL with beam
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=+2 mm
software trigger
no telescope

this is RIGHT position
  26   Sun Jun 1 15:08:17 2008 Markus FriedlSiLCAPVDAQ only (0-sup)run000310000001.06.2008 15:05:5101.06.2008 15:33:58
SiLC beam test - CERN SPS June 2008 - HIT MODE
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-2.75 mm
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12 (manually)
no telescope

This is MID position
APVDAQ runs in HIT MODE (=0-suppressed)
acquisition rate ~300 Hz during spill
  25   Sun Jun 1 15:02:51 2008 Markus FriedlSiLCAPVDAQ onlyped0031000001.06.2008 15:00:5401.06.2008 15:04:14
SiLC beam test - CERN SPS June 2008 - PEDESTAL with beam
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-2.75 mm
software trigger
no telescope

PEDESTAL WITH BEAM (10k) @ MID
  24   Sun Jun 1 14:58:53 2008 Markus FriedlSiLCAPVDAQ onlyped0021000001.06.2008 14:55:3101.06.2008 14:59:06
SiLC beam test - CERN SPS June 2008 - PEDESTAL
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
software trigger
no telescope

PEDESTAL with BEAM (10k events) @ LEFT
  23   Sun Jun 1 14:36:23 2008 Markus FriedlSiLCAPVDAQ only (0-sup)run000210000001.06.2008 14:25:4301.06.2008 14:54:14
SiLC beam test - CERN SPS June 2008 - HIT MODE
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
trigger: 9 mm opening, TLUControl.exe -d 2 -a 12 (manually)
no telescope

This is LEFT position
APVDAQ runs in HIT MODE (=0-suppressed)
acquisition rate ~300 Hz during spill
  21   Sun Jun 1 01:56:47 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup)run272010000001.06.2008 01:51:4501.06.2008 07:48:09
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-7.5 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12
telescope: zero supressed, new firmware

horizontal position ("target") = -7.5mm
this is LEFT position
  20   Sat May 31 22:54:29 2008 Markus FriedlSiLCAPVDAQ + telescope (0-sup)run271910000031.05.2008 22:34:3801.06.2008 01:49:30
SiLC beam test - CERN SPS June 2008
8 modules, HV=100V, 40MHz, 6 samples, hor stage :=-2.75 mm
trigger: 9 mm opening, TLUControl.exe -d 10 -a 12 (now for real)
telescope: zero supressed, new firmware

horizontal position ("target") = -2.75mm
this is MID position
  1   Tue May 6 13:51:43 2008 Thomas BergauerotherEquipment list    
Slow Control:
K2410 SMU
K2700 Scanning Voltmeter
Shut-Widerstand-Platine
Flachbandkabel
TRHX + 2 Sensoren + Kabel
Koax-Kabel + Adapter auf Banane
LV-Power-Supplies
Die Katze (Belle-HV-Supply)

DAQ:
Chrisu-PC (inkl. Keyboard, Maus, 2 Monitore)
9U-VME-Crate samt Modulen und PS
DOCK-Box
VME-Kabel (bockig)
30m-Kabel (8xCat7, 2xCat5, 2xgrau)
Lemo-Kabel
100pin-Flachkabel
Bananenkabel
Hybridkabel
Special TLU-Adapter (flipping pin order of RJ45)
Schrauben für Crate-Montage

DUT:
9 SiLC-Module
Micron-Modul
3 Belle-Module + Rahmen
Schrauben für Montage am Drehteller

EDV:
Netzwerkkabel
Netzwerk-Switch
WLAN-Router WRT54GL
1TB externe Festplatte
Webcam
USB-Stick

Tools:
Scope + 4 Probes
Diverse Adaptoren Lemo-BNC, Lemo-Lemo
Taschenlampe
Massband
Multimeter
Werkzeug (Schraubenzieher & Co)
Pinzetten
Laserpointer
Schwarze Fetzen
Scotch tape
Kabelbinder
Adapter f. Steckdosen falls erforderlich
Verteiler-Leisten
Tixo klein & gross

Misc:
5 pcs. SiLC Alignment Sensors for Marcos Fernandez Garcia
Fondueset Wink
Digitalkamera
Akkus+Ladegerät
Dickes Logbook
Kugelschreiber/Bleistifte
Pflaster
VME-6U-PS zur Reparatur
2 x Pixel-FED für W.J. & D.K.
  2   Wed May 7 10:43:09 2008 Thomas BergauerSiLCDocumentation: twiki, Stephans Hardware Drawings,....    

DUT, APVDAQ Documentation

CERN TWiki: https://twiki.cern.ch/twiki/bin/view/Main/SiLCTestbeam

Stephan's Documentation: http://wwwhephy.oeaw.ac.at/u3w/s/shaensel/www/HEPHY-Testbeam08/

Telescope:

EUDAQ @ hepforge
LCIO homepage at DESY
JRA1 Meeting with Software tutorial (siehe "Software Session" -> "EUtelescope Tutorial")
  3   Wed May 7 16:28:23 2008 stephan hänselSiLCPhotos    
Module Photos

topview of module (without cover)

bottomview of module (without cover)

8 modules on table
Attachment 1: module-top.jpg
module-top.jpg
Attachment 2: module-bottom.jpg
module-bottom.jpg
Attachment 3: 8Modules.jpg
8Modules.jpg
  4   Fri May 9 11:46:36 2008 Markus FriedlSiLCData file format(work in progress)   
APVDAQ Data Analysis
====================

The Vienna APVDAQ system has its origin in the late 1990s, and has grown and been improved since then.
Along with the hardware, also the software has grown and hence now consists of several steps rather
than a single piece of software.


DAQ and Analysis Chain
----------------------

Step 0: APVDAQ Software (=online) - CVI/LabWindows under Windows
        * controls and reads hardware, provides quick online analysis for online data quality check
        * can record software (pedestal), hardware (normal) or calibration runs
        * saves raw data (default) or hardware-zero-suppressed data

Step 1: APVDAQ_Analysis - CVI/Labwindows under Windows
        * essentially an improved version of step 0, reads step 0 data from file and performs pedestal 
          subtraction, common-mode correction, hit finding and clump finding (=2D-clustering; we record
          typically 6 samples along the shaped waveform for each event for later peak time reconstruction;
          thus clustering is not only done along strip axis, but also in time -> we search for contiguous
          hit clouds within the two-dimensional x-t-domain and sum up the cluster for each time point)
        * saves clustered waveform hit data (typically 6 sampled values per hit)

Step 2: hitfitgui - ROOT under Linux
        * reads the clustered waveform hit data from step 1 and performs a waveform fit for each hit with the
          reference waveform created from calibration data, resulting in peak amplitude and peak time for each
          hit which is compared to a reference time obtained with a TDC (included in the APVDAQ hardware)
        * saves peak amplitude and time information per hit

Step 3: anarun.C - ROOT under Linux
        * reads the hit properties file from the previous step and fills the data into several histograms like
          Signal, SNR, Noise, Cluster Width, Eta distribution etc. for subsequent graphical display, including
          Landau*Gauss fits and p-n side correlations
        * saves several plot canvasses as PS files


What we don't have
------------------

Tracking, alignment and such things. I think that the best starting point for these functions is the step 2
output data, as this is the most compact form of data and almost directly represents spatial hit points.


General things to consider
--------------------------

* All counting starts from zero
* Strip numbers are counted by hybrids and can span over up to 4 APV chips (=strip numbers 0..511)
* The first 600 events are always software-triggered and used for pedestal and noise evaluation. Thus, event
  numbers 0..599 will never appear in the zero-suppressed data
* The TLU event number is stored separately and does not correspond to the APVDAQ internal event number
* Zones were introduced to label detector regions of different properties, such as the 16 (!) geometrically
  different regions of the SiLC test structures, each comprising only 16 strips
         

Step 1 (APVDAQ_Analysis) output data format
-------------------------------------------

The first step of offline analysis produces a zero-suppressed data file stream out
of the raw data file, thus reducing the file size considerably. 
The zero-suppressed file (file name ends with "_cluster.hit") uses the following structure.


#define MAX_SUBEVENTS       6             // maximum number of samples in one readout buffer
#define MAX_HITS_PER_EVENT  200           // maximum number of hits per event
#define MAX_CLUSTERWIDTH 20               // maximum cluster width

#define P_SIDE	0                         // p-side of the sensor
#define N_SIDE	1                         // n-side of the sensor 

typedef struct {
   unsigned long event;                   // APVDAQ event number
   unsigned char numberofsubevents;	  // number of samples in this event
   unsigned short numberhits;		  // total number of hits (clumps) in this event

   unsigned char hitbegin;  	          // sample number of the begin of the hit
   unsigned char hitlength;     	  // number of samples of this hit
   unsigned short first_strip;		  // first strip of the cluster
   unsigned char clwidth;		  // cluster width
   double center_strip;  		  // center-of-gravity of the cluster (counted in strip units)
   double center_coord;  		  // coordinate of the center strip
   unsigned char side;           	  // sensor side, P_SIDE = 0, N_SIDE = 1
   unsigned char module;                  // module number (internal=0,1,...)
   unsigned char zone;			  // zone number (internal=0,1,...)
   unsigned short tlueventnumber;	  // TLU event number (was previously reserved2)

   double eta;				  // eta of cluster peak
   double clnoise;			  // calibrated cluster noise
   double reserved;			  // used for calibration constant

   double clsigcal[MAX_SUBEVENTS];	  // calibrated cluster signal of all subevents

   double tdc;                            // time of digital conversion
   
   double strsigcal[MAX_CLUSTERWIDTH][MAX_SUBEVENTS];	// calibrated strip signal of all samples
   double strnoise [MAX_CLUSTERWIDTH];			// calibrated strip noise

} Clusterhit_t;

Clusterhit_t clhits[MAX_HITS_PER_EVENT];  // cluster hits of the current event


Each structure array element describes a single clump (2D cluster) found in one sensor plane
in one particular event.
The APV25 chips read out 6 consecutive samples for each strip, spaced by 25ns (MAX_SUBEVENTS).
Hence, the term "cluster" is extended into 2D, with strip number and time sample as coordinates,
leading to a "clump".
A clump is a cluster built from one or more strips and spanning over several time samples.
The total number of clumps per event is stored in the "numberofhits" field, so the procedure
to read the complete event data is to read one element first, then numberofhits-1 more elements.


Step 2 (hitfitgui) output data format
-------------------------------------

The data structure looks very similar to the previous one, except that the (typically) 6 samples values along
the shaped waveform are replaced by a single value pair: peak amplitude and time. Well, actually, there are 3
pairs obtained in different ways, where the last one (i.e. sigcal[2] and tpeak[2]) are most accurate.
The output file (file name ends with "_cluster.hit.fit") uses the following structure.


typedef struct {
   unsigned long event;                 // master event number
   unsigned char numberofsubevents;     // number of subevents in this master event
   unsigned short numberhits;           // total number of hits (clumps) in this event
   unsigned short numfithits;           // total number of fitted hits (clumps) in this event

   unsigned char hitbegin;              // subevent number of the begin of the hit
   unsigned char hitlength;             // number of subevents of this hit
   unsigned short first_strip;          // first strip of the cluster
   unsigned char clwidth;               // cluster width
   double center_strip;                 // center strip of the cluster
   double center_coord;                 // u or v coordinate of the center strip

   unsigned char side;                  // sensor side, N_SIDE, P_SIDE
   unsigned char module;                // module number (internal=0,1,...)
   unsigned char zone;                  // zone number (internal=0,1,...)

   double tdc;                          // time of digital conversion

   double eta;                          // eta of cluster peak
   double clnoise;                      // calibrated cluster noise

// OLD:
//   double reserved;                     // reserved for future use
//
// NEW:
   unsigned short tlueventnumber;	  // TLU event number
   unsigned short reserved2;
   unsigned long reserved3;

   double sigcal[3];                    // fitted hit amplitude {raw data max / expfit / calfit}
   double tpeak[3];                     // fitted peak time {raw data max / expfit / calfit}
   
   double strsigcal[MAX_CLUSTERWIDTH][MAX_SUBEVENTS];	// calibrated strip signal of all samples
   double strnoise [MAX_CLUSTERWIDTH];			// calibrated strip noise

} FittedHit_t;

FittedHit_t fithits[MAX_HITS_PER_EVENT];


Each structure array element describes a single clump (2D cluster) found in one sensor plane
in one particular event.
The total number of clumps per event is stored in the "numberofhits" field, so the procedure
to read the complete event data is to read one element first, then numberofhits-1 more elements.





To be continued...
  5   Fri May 9 15:29:28 2008 Thomas BergauerSiLCSensor Layout    
  pplus strip number of
  width intermediate
strips [µm] strips
16 6 no
16 10 no
16 12.5 no
16 15 no
16 20 no
16 25 no
16 6 single
16 7.5 single
16 10 single
16 12.5 single
16 15 single
16 17.5 single
16 6 double
16 7.5 double
16 10 double
16 12.5 double

Stephan: weil ichs immer hier suche hab ich das Wafer Layout file geadded ;-)

Attachment 1: test-AC-2.pdf
Attachment 2: 070516-SiLC_WaferLayout.pdf
  6   Wed May 14 09:21:39 2008 stephan hänselSiLCcapacity measurements - HPK-ILC-TS-6687-24    
ich hab mal die Kapazitäts-Messungen vom Thomas in ein Diagram gegeben

interessant ist, dass die Kapazität mit 2 intermediate strips (int. strips) kleiner ist als mit einem int. strip -> das bedeutet, dass der eine int. strip breiter ist als die 2 int. strips zusammen - oder?
weiters dürfte die breite des einen int. strips mit der stripwith leicht variieren

(zur Erinnerung: Plattenkondensator - C = e eo A / d )
Attachment 1: capacity-TS24.eps
Attachment 2: capacity_measurements_ACTS-24.opj
  7   Wed May 14 16:15:30 2008 Markus FriedlBELLEMicron DDD5 Photos    
This is the new Micron DDD5 double-sided module with 3+3 APV25 readout chips on each side.

The p-side flex hybrid sits at the edge of the sensor, while the n-side flex hybrid is located on top of about
1/3 of the sensor, separated by 1mm of Rohacell.

Sensor data (copied from the Micron catalogue):

DESIGN DDD5 - AC COUPLED ION IMPLANTED TOTALLY DEPLETED DOUBLE SIDED DOUBLE METAL MICROSTRIP DETECTOR

SILICON DETECTOR TYPE: AC coupled ion implanted totally depleted silicon microstrip detector.
DESIGN: Double sided, two metal layers on NN+ 6 inch wafer technology.

JUNCTION SIDE
No STRIPS: 384
STRIP PITCH: 50 µm

OHMIC SIDE
First Metal
No STRIPS: 768
STRIP PITCH: 153.5 µm
Second Metal
No STRIPS: 384
STRIP PITCH: 49.5 µm

POLYSILICON RESISTOR: 2.5 ± 0.5 M
COUPLING CAPACITOR: 100 pF
SILICON THICKNESS: 300 ± 10 µm
CHIP DIMENSIONS: 120.125 x 21.2 mm2
FULL DEPLETION VOLTAGE (FD): 50 V maximum
OPERATING VOLTAGE: FD to 2FD

EXPERIMENTS: D2, FNAL
Attachment 1: micron_pside.jpg
micron_pside.jpg
Attachment 2: micron_nside.jpg
micron_nside.jpg
Attachment 3: micron_pside_detail.jpg
micron_pside_detail.jpg
Attachment 4: micron_nside_detail.jpg
micron_nside_detail.jpg
  8   Mon May 19 15:14:40 2008 Markus FriedlotherTentative Beam Test Schedule    
Wed 28 May: ~16:00 arrival, unpacking
Thu 29 May: installation
Fri 30 May: beam on

1) Telescope + 8xSilC (~7hrs, overnight; first part)
2) 8xSilc, no telescope (fast runs during day)
3) Telescope + 8xSilC (~7hrs, overnight; second part after DUT shift)
4) 1xSilc, rotation
5) Belle, telescope

* starting telescope alignement
* adc delay scan, intcal, pedrun, pedcorr
* DUT alignement
* std. settings, telescope zero supr.(zp) 1st half, lunch break
* std. settings, telescope zero supr. 2nd half
* std. settings, telescope raw data, 1st half
* std. settings, telescope raw data, 2nd half
* optionally HV scan, tel. zp., (10 HV settings --> 2x 10 runs)
* unmount 7 DUTs
* std run 0 deg., (2 runs)
* angle scan (about 10 runs)      
* install Belle DUT
* std. settings, telescope raw, transparent mode
* std. settings, telescope sp, transparent mode, high statistics
* std. settings, telescope sp, processed mode, high statistics
  9   Mon May 19 15:21:49 2008 Markus FriedlotherCERN SPS page 1    

SPS Status

SPS Page 1 - http://hpslweb.cern.ch/frame/java/1.1/view110-java.html

Manual - http://jwenning.web.cern.ch/jwenning/documents/SPS/Operation/Page-1%20description.htm

Linac, PSB, CPS Status

Linac, PSB, CPS Status
  10   Fri May 23 15:17:49 2008 Markus FriedlSiLCModule/chip/strip/zone numbering scheme(work in progress)   
The SILC DUT is a stack of 8 silicon sensors surrounded by the telescope.
The spacing between each of the 8 layers is 20mm. Seen with the beam, the fourth layer is exactly centered
between the telescope legs. This means that the stack as a whole is not exactly centered, as there is no
'center' module with an even number of layers. Please refer to drawings "telecope_single_dut.gif" and
"telescope_8_dut.gif" below.

Each sensor has 256 strips, which are read out by 2 APV25 chips. The numbering order of the modules follows the
beam direction (see drawing "silc_dut_stack_beam.jpg"). Modules will have the connector (and thus APV25 hybrid)
at the top as shown in the photos. The numbering scheme within one module is shown in drawing
"silc_dut_beam.jpg": Looking with the beam, strips are numbered from right to left. The strip pitch is 50um
everywhere.

The APVDAQ software works on APV25 level for the data acquisition, where raw data is saved. In that case, the
APVs are consecutively numbered 0,1 (=module 0), 2,3 (=module 1), 4,5 (=module 2), ... ,14,15 (=module 7).
In later steps of the analysis, data are presented on a module [0..7] / strip [0..511] base.
Zone numbers were removed, now everything is zone=1.
(Zone 0 is a reserved value and hence the actual zone counting starts with 1.)

The 256 strips are divided into 16 groups of 16 strips each with different strip width and intermediate strips,
according to the table below:
	 	pplus strip  	number of
		width 	intermediate
group#	strips 	[µm] 	strips
 0	16 	6 	none
 1	16 	10 	none
 2	16 	12.5 	none
 3	16 	15 	none
 4	16 	20 	none
 5	16 	25 	none
 6	16 	6 	single
 7	16 	7.5 	single
 8	16 	10 	single
 9	16 	12.5 	single
10	16 	15 	single
11	16 	17.5 	single
12	16 	6 	double
13	16 	7.5 	double
14	16 	10 	double
15	16 	12.5 	double

Please note that the strip pitch is 50µm everywhere, but between each group there is a gap of a single missing
strip. Hence, when calculating the coordinate from the strip number, one must take those distinctive gaps into
account.

We assume that we have a fractional strip position, where the fraction denotes (e.g.) the center of gravity of
the cluster. In order to convert this into a coordinate, we can use the following approach (where s is the
(fractional) strip number and x ist the fractional coordinate [µm]):

 /* *** tested and works *** */

double strip2x(double strip)
{
 unsigned short ints;

 // this is the integral part of the strip number
 ints = (unsigned short) strip;
 
 return ( 50.0 * ( strip + ( ints >> 4 ) ) + ( ( (ints+1) & 15 ) ? 0.0 : ( strip - ints ) * 50.0 ) );
 //       pitch    strip 
 //                          gaps between zones
 //                                                outside gap ? do nothing
 //                                                                      account for double pitch within gap 
    
}
Attachment 1: telescope_single_dut.gif
telescope_single_dut.gif
Attachment 2: telescope_8_dut.gif
telescope_8_dut.gif
Attachment 3: silc_dut_stack_beam.jpg
silc_dut_stack_beam.jpg
Attachment 4: silc_dut_beam.jpg
silc_dut_beam.jpg
  11   Mon May 26 15:38:53 2008 Markus FriedlSiLCHow to run APVDAQ    
Power-on Procedure
==================

PC logon: user "testbeam", pwd "sensor"

Order for switching on the hardware (not strict):
* VME 9U crate
* keithley instruments
* +-5V (fat) 2 lab power supplies (left stack)
* other 3 lab power supplies (right stack)
    BE CAREFUL NOT TO CHANGE DIALS AT ALL DURING SWITCHING!!!

Run ResMan.exe (shortcut on desktop) and click OK to close
Start longterm-R31.vi (shortcut on desktop) and start HV bias
Start APVDAQ.exe 

Now everything is on and ready to operate.
This is also the condition after a run is finished.


Start Run (see screenshot below)
================================

1. select proper run type (if different from previous run), typically
 Hardware (beam) or
 Software (pedestal) or
 Internal Calibration

2. open proper config file (if different from previous run), one of
 cern08_silc_all_single.cfg   (8 DUTs, 1 sample)  - for software (pedestal) and intcal runs
 cern08_silc_all_multi6.cfg   (8 DUTs, 6 samples) - for hardware (beam) runs

 cern08_silc_mod03_single.cfg (1 DUT, module 03, 1 sample)  - for software (pedestal) and intcal runs
 cern08_silc_mod03_multi6.cfg (1 DUT, module 03, 6 samples) - for hardware (beam) runs
 

3. select file name (typically: increase run number)

4. switch Write File ON (if turned off)

5. write some useful comments (conditions, HV, etc)

6. enter number of events

7. hit "Start Run" and relax or cry for help :-)


Additional Info
===============

path to APVDAQ:   e:\cvi-projects\apvdaq_fadc
path to Longterm: e:\labview-projects\longterm R3.1
path to data:     f:\testbeam\cern_jun08\silc\data
Attachment 1: panel_instruction.gif
panel_instruction.gif
Attachment 2: cern08_silc_all_single.cfg
# 40 mhz
# single peak mode (1 sample)
# 50ns peaking time
# 30ns trigger window (built from 5ns window, thus ~12.5ns later)
# NECO
#
# Data processing with FADC+PROC
# SPS Testbeam - full setup
# FADC 0  four hybrids
# FADC 1  four hybrids
#
#
# CI 07 may 2008
#
#
# Lines preceded by a # or ; sign are ignored.
#
# [rem] comments a whole section until the next section start marked by [xxx] .
#

# [vme]
# VME addresses are given in the format
#  {module_name} = {vme_module_number},{vme_address_hex}
#  nec ... NECO module
#  adf ... particular FADC module
#
# Please note that the address ranges are not defined here,
# they are implicitly given by the hardware.
# Module numbers must fill from 0 (this is not checked).
# Please note that no range checking is performed.
# There is no access to VME modules that are not included in this list,

[vme]
nec = 0,0x1a000000

adf = 0,0x1b000000
adf = 1,0x2b000000

# [nec]
# NECO related information
#  mod = 0|1,{shift_register_delay},{adc_range},{win_delay},{win_length},{dead_time},{time_lat},{max_trg}
#          (default: 0,75,0,50?,900?,36,2,1)
#  res = {list of entries in reset sequence}                (default: 2,4)
#  cal = {list of entries in cal sequence}			(default: 2,3,250,251)
#  sw5 = {list of entries in single cal sequence}		(default: 2,3)
#  str = {list of entries in software trigger sequence}		(default: 75)
#  htr = {list of entries in hardware trigger sequence}		(default: 74)
#
# mod specifies to use either the sequencer (0) or the shift register (1) for hardware trigger and the
#  delay of the shift register (0..255); adc_range (0=1Vpp, 1=2Vpp) -- ignored; win_delay and win_length define
#  the starting point (relative to the APV trigger) and length of the ADC gate in transparent mode; dead_time is
#  the number of 254MHz clock cycles which are set to zero for time measurement after an incoming trigger;
#  time_lat is the latency for time measurement in terms of 40MHz clock cycles; max_trg is the number of incoming
#  triggers which required to activate the veto logic (usually 1; 0 completely disables the veto logic)
# res, cal, sw5, str and htr are containing the bits to set in the 256-element sequencer memory (nothing is set at -1)
# Please note that cal+str together produce a calibration request plus subsequent normal trigger, so the time
#  between them is the latency. sw5 is used to send a single cal request to achieve the correct polarity in
#  case the APV inverter is turned on (this feature only works for entire MAMBOs halves = groups of 3 REBOs)
# 
# These settings are quite fragile! Do not modify until you know exactly what you are doing.

[nec]

# 30m cables, 40mhz, Tp=50ns, single-trigger 
#mod = 0,75,0,70,250,36,2,1
#htr = 61,-1,-1,-1,-1,-1,-1,-1
#str = 100,-1,-1,-1,-1,-1,-1,-1

# TESTBEAM Nov 07, 30m cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 59,62,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, single-trigger (1 samples)
mod = 0,75,0,70,250,36,2,1
htr = 63,-1,-1,-1,-1,-1,-1,-1
str = 100,-1,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 61,64,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1


#common settings
res =  2, 4, -1, -1,-1,-1,-1,-1
cal =  2, 3,250,251,-1,-1,-1,-1
sw5 =  2, 3, -1, -1,-1,-1,-1,-1




# [daq]
# DAQ related specifications are given in the format
#  ads = {N},{search_max_subevents},0,x
#  ini = {initevents},{readout_mode},0,x
#  deh = {module_position},{apv_position},0,x
#  i2t = {N},0,0,x
#  pat = 0,0,0,{data_file_path}
#  clk = {N},{Delay25 frequency range},0,x
#  pdl = {Trigger input delay},0,0,x
#  crd = {crate_number},{clkdel},{trgdel},x
#
# ads N gives the number of samples that are read out from the FIFO1 in transparent mode, search_max_subevents is the
#  maximum number of subevents to search for within one ADC stream (default=1).
# ini: initevents is the number of software triggers in the beginning of a run for pedestal and noise
# evaluation. At the beginning of each run, 2*initevents are generated by software, after that the 
# selected trigger source (hardware, software of calibration) is activated. The initial evaluation
# events are written to disk as normal events are.
# ini: readout_mode defines whether events beyond the initevents are read in raw transparent mode from FIFO1 (0) or
#  in processed mode (1) where only hit information is read from FIFO3
# deh is the APV chip for which single strip histograms are recorded
# i2t is the maximum number of I2C retries in case of failure
# pat specifies the save path for data files (must include a trailing backslash!)
# clk gives the system clock period in integer ns (25 max.) and the frequency range for the Delay25 chip:
#  0...40 MHz, 1...80 MHz, 2...32 MHz, 3...64 MHz
# pdl specifies the delay setting for the trigger input in 0.5ns steps (0..49)
# crd define the global clock and trigger delays between NECO and SVD3_buffer for crates 0 and 1
#  NOTE: clock and trigger is NOT propagated to any crate(s) NOT specified here


[daq]

# TESTBEAM Nov 07
#Standard
ads = 250,1,0,x

# TESTBEAM Nov 07
#Multitrigger (6)
#ads = 950,6,0,x

# RAW (transparent mode) readout
ini = 300,0,0,x

# PROCESSED readout
#ini = 300,1,0,x

deh = 1,0,0,x
i2t = 5,0,0,x
pat = 0,0,0,F:\\testbeam\\cern_jun08\\silc\\data\\

#standard 40mhz clock (25ns)
clk = 25,0,0,x
pdl = 25,0,0,x

#crate distribution delays (set to mid-range to allow adjustments in both directions)
crd = 0,25,25,x

#we don't use crate 1, so we don't set any delay here -> no clock/trigger to crate 1
###crd = 1,25,25,x


# [hit]
# Hit recognition variables are specified here
#  hcs = {hitcut_seed_strip},{hitcut_neighbor_strips}
#  nok = {x.x},0
#  
#
# hcs gives seed and neighbor hit cuts in units of strip sigma
# nok states the threshold over average noise at which strips are excluded from further analysis (to exclude noisy strips)

[hit]
# si sensor
hcs = 4.0,4.0

# do not exclude strips
nok = 2000.0,0


# [cal]
# Calibration related data
#  lvl = {level},0
#  lat = {latbeg},{latend}
#  sam = {average_samples},{number of samples in 6-tuple mode}
#  grp = {number_of_groups},0
#  lg6 = {latency},{group}
#  lv6 = {startlevel},{endlevel}
#
# lvl is the CLVL amplitude (0..255), 1 is 625e-, 36 is 1 MIP (22500e-) nominally, in reality 26 is 1 MIP
# lat is the Latency range to cover (latend-latbeg>=2, latend-latbeg<=15)
# sam is the number of samples to average per position for normal and 6-tuple modes
# grp is how many groups to scan (<=8), first group is strips 0,8,16,..., second group is 1,9,17,..., ...
# lg6 defines the latency in 6-tuple mode and which group to observe in that mode
# lv6 defines the scan range of amplitude in 6-tuple mode

[cal]
#real 1 MIP level (22400e)
lvl = 26,0

#real 5 MIPs level
#lvl = 130,0

#LAT=95/98 Calibration (short display)
#lat = 89,100

#LAT=95/98 Calibration (short display for >=50mhz)
#lat = 81,98

#LAT=95/98 Calibration (long peak mode tail display)
lat = 75,100

#common settings
sam = 50,150
grp = 8,0

#6-tuple mode settings
lg6 = 97, 1
#lv6 =  1,95
lv6 =  50,52




# [i2c]
# This section defines one or more I2C sets for the APV25. In the [mod] section, those sets are referenced to by their number.
#  ia2 = {number},{mode},{lat},{ipre},{ipcasc},{ipsf},{isha},{issf},{ipsp},{imuxin},{vfp},{vfs},{vpsp},{muxgain}
#
# The I2C settings must be individually numbered (ascending from 0). The easiest case is to use the same
# settings for all chips of one type, but one could go so far to use separate settings for each chip.
# vadj/vpsp is set individually for each apv in the [mod] section, the value specified here is meaningless.

[i2c]

# apv25s1, peak, inverter ON, Tp=50ns, (p side)
ia2 =          0,    63,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, peak, inverter OFF, Tp=50ns, (n side)
ia2 =          1,    31,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# apv25s1, multi-peak, inverter ON, Tp=50ns, (p side)
#ia2 =          0,    61,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, multi-peak, inverter OFF, Tp=50ns, (n side)
#ia2 =          1,    29,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# [mod]
# Detector module (actually hybrid) specifications are given in the format
#  mod = {module_position},{crate_number},{mambo_number},{rebo_number},{hybrid_number},m,{AD8128_peak},{rebo_clkdelay},{rebo_trgdelay},0,0,0,0,{Name}
#  apv = {module_position},{apv_position},{i2c_address},{i2c_settings},{vadj/vpsp},x,0,0,{fadc_offset},{fadc_number},{fadc_channel},{fadc_clkdelay [0..49]},{AD8128_gain},x
#
# mod gives the hybrid/module properties: The position counts from 0 to 7 in beam direction,
#  Name must not contain blanks ("_" is allowed).
# apv describes the chips located on a hybrid 
#  and the ADC channel where they are read out, either a Vienna ADC (a) or a FED (f).
# The ADC offset is only available with the Vienna ADCs and shifts the baseline.
# The individual chip vadj setting dominates over the [i2c] setting.


[mod]

# module 0
mod = 0,0,0,2,0,m,45,25,0,0,0,0,0, 0_SiLC_05/05
apv = 0,0,36,0,30,x,0,0,5,0,1,12,100,x
apv = 0,1,38,0,30,x,0,0,5,0,2,15,100,x
# module 1
mod = 1,0,0,2,1,m,45,25,0,0,0,0,0, 1_SiLC_07/07
apv = 1,0,36,0,30,x,0,0,5,0,5,15,100,x
apv = 1,1,38,0,30,x,0,0,5,0,6,16,100,x
# module 2
mod = 2,0,0,2,2,m,45,25,0,0,0,0,0, 2_SiLC_06/03
apv = 2,0,36,0,30,x,0,0,5,0,9,10,100,x
apv = 2,1,38,0,30,x,0,0,5,0,10,15,100,x
# module 3
mod = 3,0,0,2,3,m,45,25,0,0,0,0,0, 3_SiLC_04/04
apv = 3,0,36,0,30,x,0,0,5,0,13,12,100,x
apv = 3,1,38,0,30,x,0,0,5,0,14,14,100,x
# module 4
mod = 4,0,1,1,0,m,45,25,0,0,0,0,0, 4_SiLC_03/10
apv = 4,0,36,0,30,x,0,0,110,1,1,14,100,x
apv = 4,1,38,0,30,x,0,0,110,1,2,15,100,x
# module 5
mod = 5,0,1,1,1,m,45,25,0,0,0,0,0, 5_SiLC_12/08
apv = 5,0,36,0,30,x,0,0,110,1,5,14,100,x
apv = 5,1,38,0,30,x,0,0,110,1,6,16,100,x
# module 6
mod = 6,0,1,1,2,m,45,25,0,0,0,0,0, 6_SiLC_10/02
apv = 6,0,36,0,30,x,0,0,110,1,9,12,100,x
apv = 6,1,38,0,30,x,0,0,120,1,10,15,100,x
# module 7
mod = 7,0,1,1,3,m,45,25,0,0,0,0,0, 7_SiLC_20/09
apv = 7,0,36,0,30,x,0,0,125,1,13,10,100,x
apv = 7,1,38,0,30,x,0,0,115,1,14,14,100,x


# [bad]
# Bad channels description table
#  bad = {module_position},{apv_position},{List of 18 strip values or -1}
#
# Maps bad channels, which are then excluded from hit search. Up to 18 bad strips can be entered per line,
# more lines per APV are allowed. Unused values in the list must be filled with -1

[bad]
#bad = 2,0,73,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1

[sen]
# sensor configuration
#  sen = {sensor number},{number strips on p side},{numeration direction p},{number strips on n side},{numeration direction n},{first_full},{last_full},{pitch p [µm]}, {pitch n [µm]},{angle [°]},{height [µm]}
#  apv = {sensor number},{module_position},{apv_position},{first_strip},{num_floating},{side},0,0,0,0,0
... 193 more lines ...
Attachment 3: cern08_silc_all_multi6.cfg
# 40 mhz
# multi peak mode (6 sample)
# 50ns peaking time
# 30ns trigger window (built from 5ns window, thus ~12.5ns later)
# NECO
#
# Data processing with FADC+PROC
# SPS Testbeam - full setup
# FADC 0  four hybrids
# FADC 1  four hybrids
#
#
# CI 07 may 2008
#
#
# Lines preceded by a # or ; sign are ignored.
#
# [rem] comments a whole section until the next section start marked by [xxx] .
#

# [vme]
# VME addresses are given in the format
#  {module_name} = {vme_module_number},{vme_address_hex}
#  nec ... NECO module
#  adf ... particular FADC module
#
# Please note that the address ranges are not defined here,
# they are implicitly given by the hardware.
# Module numbers must fill from 0 (this is not checked).
# Please note that no range checking is performed.
# There is no access to VME modules that are not included in this list,

[vme]
nec = 0,0x1a000000

adf = 0,0x1b000000
adf = 1,0x2b000000

# [nec]
# NECO related information
#  mod = 0|1,{shift_register_delay},{adc_range},{win_delay},{win_length},{dead_time},{time_lat},{max_trg}
#          (default: 0,75,0,50?,900?,36,2,1)
#  res = {list of entries in reset sequence}                (default: 2,4)
#  cal = {list of entries in cal sequence}			(default: 2,3,250,251)
#  sw5 = {list of entries in single cal sequence}		(default: 2,3)
#  str = {list of entries in software trigger sequence}		(default: 75)
#  htr = {list of entries in hardware trigger sequence}		(default: 74)
#
# mod specifies to use either the sequencer (0) or the shift register (1) for hardware trigger and the
#  delay of the shift register (0..255); adc_range (0=1Vpp, 1=2Vpp) -- ignored; win_delay and win_length define
#  the starting point (relative to the APV trigger) and length of the ADC gate in transparent mode; dead_time is
#  the number of 254MHz clock cycles which are set to zero for time measurement after an incoming trigger;
#  time_lat is the latency for time measurement in terms of 40MHz clock cycles; max_trg is the number of incoming
#  triggers which required to activate the veto logic (usually 1; 0 completely disables the veto logic)
# res, cal, sw5, str and htr are containing the bits to set in the 256-element sequencer memory (nothing is set at -1)
# Please note that cal+str together produce a calibration request plus subsequent normal trigger, so the time
#  between them is the latency. sw5 is used to send a single cal request to achieve the correct polarity in
#  case the APV inverter is turned on (this feature only works for entire MAMBOs halves = groups of 3 REBOs)
# 
# These settings are quite fragile! Do not modify until you know exactly what you are doing.

[nec]

# 30m cables, 40mhz, Tp=50ns, single-trigger 
#mod = 0,75,0,70,250,36,2,1
#htr = 61,-1,-1,-1,-1,-1,-1,-1
#str = 100,-1,-1,-1,-1,-1,-1,-1

# TESTBEAM Nov 07, 30m cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 59,62,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
mod = 0,75,0,70,950,36,2,1
htr = 61,64,-1,-1,-1,-1,-1,-1
str = 100,103,-1,-1,-1,-1,-1,-1

#common settings
res =  2, 4, -1, -1,-1,-1,-1,-1
cal =  2, 3,250,251,-1,-1,-1,-1
sw5 =  2, 3, -1, -1,-1,-1,-1,-1




# [daq]
# DAQ related specifications are given in the format
#  ads = {N},{search_max_subevents},0,x
#  ini = {initevents},{readout_mode},0,x
#  deh = {module_position},{apv_position},0,x
#  i2t = {N},0,0,x
#  pat = 0,0,0,{data_file_path}
#  clk = {N},{Delay25 frequency range},0,x
#  pdl = {Trigger input delay},0,0,x
#  crd = {crate_number},{clkdel},{trgdel},x
#
# ads N gives the number of samples that are read out from the FIFO1 in transparent mode, search_max_subevents is the
#  maximum number of subevents to search for within one ADC stream (default=1).
# ini: initevents is the number of software triggers in the beginning of a run for pedestal and noise
# evaluation. At the beginning of each run, 2*initevents are generated by software, after that the 
# selected trigger source (hardware, software of calibration) is activated. The initial evaluation
# events are written to disk as normal events are.
# ini: readout_mode defines whether events beyond the initevents are read in raw transparent mode from FIFO1 (0) or
#  in processed mode (1) where only hit information is read from FIFO3
# deh is the APV chip for which single strip histograms are recorded
# i2t is the maximum number of I2C retries in case of failure
# pat specifies the save path for data files (must include a trailing backslash!)
# clk gives the system clock period in integer ns (25 max.) and the frequency range for the Delay25 chip:
#  0...40 MHz, 1...80 MHz, 2...32 MHz, 3...64 MHz
# pdl specifies the delay setting for the trigger input in 0.5ns steps (0..49)
# crd define the global clock and trigger delays between NECO and SVD3_buffer for crates 0 and 1
#  NOTE: clock and trigger is NOT propagated to any crate(s) NOT specified here


[daq]

# TESTBEAM Nov 07
#Standard
#ads = 250,1,0,x

# TESTBEAM Nov 07
#Multitrigger (6)
ads = 950,6,0,x

# RAW (transparent mode) readout
ini = 300,0,0,x

# PROCESSED readout
#ini = 300,1,0,x

deh = 1,0,0,x
i2t = 5,0,0,x
pat = 0,0,0,F:\\testbeam\\cern_jun08\\silc\\data\\

#standard 40mhz clock (25ns)
clk = 25,0,0,x
pdl = 25,0,0,x

#crate distribution delays (set to mid-range to allow adjustments in both directions)
crd = 0,25,25,x

#we don't use crate 1, so we don't set any delay here -> no clock/trigger to crate 1
###crd = 1,25,25,x


# [hit]
# Hit recognition variables are specified here
#  hcs = {hitcut_seed_strip},{hitcut_neighbor_strips}
#  nok = {x.x},0
#  
#
# hcs gives seed and neighbor hit cuts in units of strip sigma
# nok states the threshold over average noise at which strips are excluded from further analysis (to exclude noisy strips)

[hit]
# si sensor
hcs = 4.0,4.0

# do not exclude strips
nok = 2000.0,0


# [cal]
# Calibration related data
#  lvl = {level},0
#  lat = {latbeg},{latend}
#  sam = {average_samples},{number of samples in 6-tuple mode}
#  grp = {number_of_groups},0
#  lg6 = {latency},{group}
#  lv6 = {startlevel},{endlevel}
#
# lvl is the CLVL amplitude (0..255), 1 is 625e-, 36 is 1 MIP (22500e-) nominally, in reality 26 is 1 MIP
# lat is the Latency range to cover (latend-latbeg>=2, latend-latbeg<=15)
# sam is the number of samples to average per position for normal and 6-tuple modes
# grp is how many groups to scan (<=8), first group is strips 0,8,16,..., second group is 1,9,17,..., ...
# lg6 defines the latency in 6-tuple mode and which group to observe in that mode
# lv6 defines the scan range of amplitude in 6-tuple mode

[cal]
#real 1 MIP level (22400e)
lvl = 26,0

#real 5 MIPs level
#lvl = 130,0

#LAT=95/98 Calibration (short display)
#lat = 89,100

#LAT=95/98 Calibration (short display for >=50mhz)
#lat = 81,98

#LAT=95/98 Calibration (long peak mode tail display)
lat = 75,100

#common settings
sam = 50,150
grp = 8,0

#6-tuple mode settings
lg6 = 97, 1
#lv6 =  1,95
lv6 =  50,52




# [i2c]
# This section defines one or more I2C sets for the APV25. In the [mod] section, those sets are referenced to by their number.
#  ia2 = {number},{mode},{lat},{ipre},{ipcasc},{ipsf},{isha},{issf},{ipsp},{imuxin},{vfp},{vfs},{vpsp},{muxgain}
#
# The I2C settings must be individually numbered (ascending from 0). The easiest case is to use the same
# settings for all chips of one type, but one could go so far to use separate settings for each chip.
# vadj/vpsp is set individually for each apv in the [mod] section, the value specified here is meaningless.

[i2c]

# apv25s1, peak, inverter ON, Tp=50ns, (p side)
#ia2 =          0,    63,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, peak, inverter OFF, Tp=50ns, (n side)
#ia2 =          1,    31,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# apv25s1, multi-peak, inverter ON, Tp=50ns, (p side)
ia2 =          0,    61,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, multi-peak, inverter OFF, Tp=50ns, (n side)
ia2 =          1,    29,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# [mod]
# Detector module (actually hybrid) specifications are given in the format
#  mod = {module_position},{crate_number},{mambo_number},{rebo_number},{hybrid_number},m,{AD8128_peak},{rebo_clkdelay},{rebo_trgdelay},0,0,0,0,{Name}
#  apv = {module_position},{apv_position},{i2c_address},{i2c_settings},{vadj/vpsp},x,0,0,{fadc_offset},{fadc_number},{fadc_channel},{fadc_clkdelay [0..49]},{AD8128_gain},x
#
# mod gives the hybrid/module properties: The position counts from 0 to 7 in beam direction,
#  Name must not contain blanks ("_" is allowed).
# apv describes the chips located on a hybrid 
#  and the ADC channel where they are read out, either a Vienna ADC (a) or a FED (f).
# The ADC offset is only available with the Vienna ADCs and shifts the baseline.
# The individual chip vadj setting dominates over the [i2c] setting.


[mod]

# module 0
mod = 0,0,0,2,0,m,45,25,0,0,0,0,0, 0_SiLC_05/05
apv = 0,0,36,0,30,x,0,0,5,0,1,12,100,x
apv = 0,1,38,0,30,x,0,0,5,0,2,15,100,x
# module 1
mod = 1,0,0,2,1,m,45,25,0,0,0,0,0, 1_SiLC_07/07
apv = 1,0,36,0,30,x,0,0,5,0,5,15,100,x
apv = 1,1,38,0,30,x,0,0,5,0,6,16,100,x
# module 2
mod = 2,0,0,2,2,m,45,25,0,0,0,0,0, 2_SiLC_06/03
apv = 2,0,36,0,30,x,0,0,5,0,9,10,100,x
apv = 2,1,38,0,30,x,0,0,5,0,10,15,100,x
# module 3
mod = 3,0,0,2,3,m,45,25,0,0,0,0,0, 3_SiLC_04/04
apv = 3,0,36,0,30,x,0,0,5,0,13,12,100,x
apv = 3,1,38,0,30,x,0,0,5,0,14,14,100,x
# module 4
mod = 4,0,1,1,0,m,45,25,0,0,0,0,0, 4_SiLC_03/10
apv = 4,0,36,0,30,x,0,0,110,1,1,14,100,x
apv = 4,1,38,0,30,x,0,0,110,1,2,15,100,x
# module 5
mod = 5,0,1,1,1,m,45,25,0,0,0,0,0, 5_SiLC_12/08
apv = 5,0,36,0,30,x,0,0,110,1,5,14,100,x
apv = 5,1,38,0,30,x,0,0,110,1,6,16,100,x
# module 6
mod = 6,0,1,1,2,m,45,25,0,0,0,0,0, 6_SiLC_10/02
apv = 6,0,36,0,30,x,0,0,110,1,9,12,100,x
apv = 6,1,38,0,30,x,0,0,120,1,10,15,100,x
# module 7
mod = 7,0,1,1,3,m,45,25,0,0,0,0,0, 7_SiLC_20/09
apv = 7,0,36,0,30,x,0,0,125,1,13,10,100,x
apv = 7,1,38,0,30,x,0,0,115,1,14,14,100,x


# [bad]
# Bad channels description table
#  bad = {module_position},{apv_position},{List of 18 strip values or -1}
#
# Maps bad channels, which are then excluded from hit search. Up to 18 bad strips can be entered per line,
# more lines per APV are allowed. Unused values in the list must be filled with -1

[bad]
#bad = 2,0,73,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1

[sen]
# sensor configuration
#  sen = {sensor number},{number strips on p side},{numeration direction p},{number strips on n side},{numeration direction n},{first_full},{last_full},{pitch p [µm]}, {pitch n [µm]},{angle [°]},{height [µm]}
#  apv = {sensor number},{module_position},{apv_position},{first_strip},{num_floating},{side},0,0,0,0,0
#  zon = {sensor number},{zone number},{first strip on p side},{last strip on p side},{first strip on n side},{last strip on n side},0,0,0,0,0
#
# sen defines the sensor proberties:
#  numeration direction can be 0 = from left to right or 1 = from right to left
#	
# apv describes the apvs connected to the sensor
... 187 more lines ...
Attachment 4: cern08_silc_mod03_single.cfg
# 40 mhz
# single peak mode (1 sample)
# 50ns peaking time
# 30ns trigger window (built from 5ns window, thus ~12.5ns later)
# NECO
#
# Data processing with FADC+PROC
# SPS Testbeam - single module
# FADC 0  one module at position 3
# FADC 1  not used
#
#
# CI 07 may 2008
#
#
# Lines preceded by a # or ; sign are ignored.
#
# [rem] comments a whole section until the next section start marked by [xxx] .
#

# [vme]
# VME addresses are given in the format
#  {module_name} = {vme_module_number},{vme_address_hex}
#  nec ... NECO module
#  adf ... particular FADC module
#
# Please note that the address ranges are not defined here,
# they are implicitly given by the hardware.
# Module numbers must fill from 0 (this is not checked).
# Please note that no range checking is performed.
# There is no access to VME modules that are not included in this list,

[vme]
nec = 0,0x1a000000

adf = 0,0x1b000000
#adf = 1,0x2b000000

# [nec]
# NECO related information
#  mod = 0|1,{shift_register_delay},{adc_range},{win_delay},{win_length},{dead_time},{time_lat},{max_trg}
#          (default: 0,75,0,50?,900?,36,2,1)
#  res = {list of entries in reset sequence}                (default: 2,4)
#  cal = {list of entries in cal sequence}			(default: 2,3,250,251)
#  sw5 = {list of entries in single cal sequence}		(default: 2,3)
#  str = {list of entries in software trigger sequence}		(default: 75)
#  htr = {list of entries in hardware trigger sequence}		(default: 74)
#
# mod specifies to use either the sequencer (0) or the shift register (1) for hardware trigger and the
#  delay of the shift register (0..255); adc_range (0=1Vpp, 1=2Vpp) -- ignored; win_delay and win_length define
#  the starting point (relative to the APV trigger) and length of the ADC gate in transparent mode; dead_time is
#  the number of 254MHz clock cycles which are set to zero for time measurement after an incoming trigger;
#  time_lat is the latency for time measurement in terms of 40MHz clock cycles; max_trg is the number of incoming
#  triggers which required to activate the veto logic (usually 1; 0 completely disables the veto logic)
# res, cal, sw5, str and htr are containing the bits to set in the 256-element sequencer memory (nothing is set at -1)
# Please note that cal+str together produce a calibration request plus subsequent normal trigger, so the time
#  between them is the latency. sw5 is used to send a single cal request to achieve the correct polarity in
#  case the APV inverter is turned on (this feature only works for entire MAMBOs halves = groups of 3 REBOs)
# 
# These settings are quite fragile! Do not modify until you know exactly what you are doing.

[nec]

# 30m cables, 40mhz, Tp=50ns, single-trigger 
#mod = 0,75,0,70,250,36,2,1
#htr = 61,-1,-1,-1,-1,-1,-1,-1
#str = 100,-1,-1,-1,-1,-1,-1,-1

# TESTBEAM Nov 07, 30m cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 59,62,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, single-trigger (1 samples)
mod = 0,75,0,70,250,36,2,1
htr = 63,-1,-1,-1,-1,-1,-1,-1
str = 100,-1,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 61,64,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1


#common settings
res =  2, 4, -1, -1,-1,-1,-1,-1
cal =  2, 3,250,251,-1,-1,-1,-1
sw5 =  2, 3, -1, -1,-1,-1,-1,-1




# [daq]
# DAQ related specifications are given in the format
#  ads = {N},{search_max_subevents},0,x
#  ini = {initevents},{readout_mode},0,x
#  deh = {module_position},{apv_position},0,x
#  i2t = {N},0,0,x
#  pat = 0,0,0,{data_file_path}
#  clk = {N},{Delay25 frequency range},0,x
#  pdl = {Trigger input delay},0,0,x
#  crd = {crate_number},{clkdel},{trgdel},x
#
# ads N gives the number of samples that are read out from the FIFO1 in transparent mode, search_max_subevents is the
#  maximum number of subevents to search for within one ADC stream (default=1).
# ini: initevents is the number of software triggers in the beginning of a run for pedestal and noise
# evaluation. At the beginning of each run, 2*initevents are generated by software, after that the 
# selected trigger source (hardware, software of calibration) is activated. The initial evaluation
# events are written to disk as normal events are.
# ini: readout_mode defines whether events beyond the initevents are read in raw transparent mode from FIFO1 (0) or
#  in processed mode (1) where only hit information is read from FIFO3
# deh is the APV chip for which single strip histograms are recorded
# i2t is the maximum number of I2C retries in case of failure
# pat specifies the save path for data files (must include a trailing backslash!)
# clk gives the system clock period in integer ns (25 max.) and the frequency range for the Delay25 chip:
#  0...40 MHz, 1...80 MHz, 2...32 MHz, 3...64 MHz
# pdl specifies the delay setting for the trigger input in 0.5ns steps (0..49)
# crd define the global clock and trigger delays between NECO and SVD3_buffer for crates 0 and 1
#  NOTE: clock and trigger is NOT propagated to any crate(s) NOT specified here


[daq]

# TESTBEAM Nov 07
#Standard
ads = 250,1,0,x

# TESTBEAM Nov 07
#Multitrigger (6)
#ads = 950,6,0,x

# RAW (transparent mode) readout
ini = 300,0,0,x

# PROCESSED readout
#ini = 300,1,0,x

deh = 1,0,0,x
i2t = 5,0,0,x
pat = 0,0,0,F:\\testbeam\\cern_jun08\\silc\\data\\

#standard 40mhz clock (25ns)
clk = 25,0,0,x
pdl = 25,0,0,x

#crate distribution delays (set to mid-range to allow adjustments in both directions)
crd = 0,25,25,x

#we don't use crate 1, so we don't set any delay here -> no clock/trigger to crate 1
###crd = 1,25,25,x


# [hit]
# Hit recognition variables are specified here
#  hcs = {hitcut_seed_strip},{hitcut_neighbor_strips}
#  nok = {x.x},0
#  
#
# hcs gives seed and neighbor hit cuts in units of strip sigma
# nok states the threshold over average noise at which strips are excluded from further analysis (to exclude noisy strips)

[hit]
# si sensor
hcs = 4.0,4.0

# do not exclude strips
nok = 2000.0,0


# [cal]
# Calibration related data
#  lvl = {level},0
#  lat = {latbeg},{latend}
#  sam = {average_samples},{number of samples in 6-tuple mode}
#  grp = {number_of_groups},0
#  lg6 = {latency},{group}
#  lv6 = {startlevel},{endlevel}
#
# lvl is the CLVL amplitude (0..255), 1 is 625e-, 36 is 1 MIP (22500e-) nominally, in reality 26 is 1 MIP
# lat is the Latency range to cover (latend-latbeg>=2, latend-latbeg<=15)
# sam is the number of samples to average per position for normal and 6-tuple modes
# grp is how many groups to scan (<=8), first group is strips 0,8,16,..., second group is 1,9,17,..., ...
# lg6 defines the latency in 6-tuple mode and which group to observe in that mode
# lv6 defines the scan range of amplitude in 6-tuple mode

[cal]
#real 1 MIP level (22400e)
lvl = 26,0

#real 5 MIPs level
#lvl = 130,0

#LAT=95/98 Calibration (short display)
#lat = 89,100

#LAT=95/98 Calibration (short display for >=50mhz)
#lat = 81,98

#LAT=95/98 Calibration (long peak mode tail display)
lat = 75,100

#common settings
sam = 50,150
grp = 8,0

#6-tuple mode settings
lg6 = 97, 1
#lv6 =  1,95
lv6 =  50,52




# [i2c]
# This section defines one or more I2C sets for the APV25. In the [mod] section, those sets are referenced to by their number.
#  ia2 = {number},{mode},{lat},{ipre},{ipcasc},{ipsf},{isha},{issf},{ipsp},{imuxin},{vfp},{vfs},{vpsp},{muxgain}
#
# The I2C settings must be individually numbered (ascending from 0). The easiest case is to use the same
# settings for all chips of one type, but one could go so far to use separate settings for each chip.
# vadj/vpsp is set individually for each apv in the [mod] section, the value specified here is meaningless.

[i2c]

# apv25s1, peak, inverter ON, Tp=50ns, (p side)
ia2 =          0,    63,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, peak, inverter OFF, Tp=50ns, (n side)
ia2 =          1,    31,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# apv25s1, multi-peak, inverter ON, Tp=50ns, (p side)
#ia2 =          0,    61,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, multi-peak, inverter OFF, Tp=50ns, (n side)
#ia2 =          1,    29,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# [mod]
# Detector module (actually hybrid) specifications are given in the format
#  mod = {module_position},{crate_number},{mambo_number},{rebo_number},{hybrid_number},m,{AD8128_peak},{rebo_clkdelay},{rebo_trgdelay},0,0,0,0,{Name}
#  apv = {module_position},{apv_position},{i2c_address},{i2c_settings},{vadj/vpsp},x,0,0,{fadc_offset},{fadc_number},{fadc_channel},{fadc_clkdelay [0..49]},{AD8128_gain},x
#
# mod gives the hybrid/module properties: The position counts from 0 to 7 in beam direction,
#  Name must not contain blanks ("_" is allowed).
# apv describes the chips located on a hybrid 
#  and the ADC channel where they are read out, either a Vienna ADC (a) or a FED (f).
# The ADC offset is only available with the Vienna ADCs and shifts the baseline.
# The individual chip vadj setting dominates over the [i2c] setting.


[mod]

# module 3
mod = 3,0,0,2,3,m,45,25,0,0,0,0,0, 3_SiLC_04/04
apv = 3,0,36,0,30,x,0,0,5,0,13,12,100,x
apv = 3,1,38,0,30,x,0,0,5,0,14,14,100,x


# [bad]
# Bad channels description table
#  bad = {module_position},{apv_position},{List of 18 strip values or -1}
#
# Maps bad channels, which are then excluded from hit search. Up to 18 bad strips can be entered per line,
# more lines per APV are allowed. Unused values in the list must be filled with -1

[bad]
#bad = 2,0,73,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1

[sen]
# sensor configuration
#  sen = {sensor number},{number strips on p side},{numeration direction p},{number strips on n side},{numeration direction n},{first_full},{last_full},{pitch p [µm]}, {pitch n [µm]},{angle [°]},{height [µm]}
#  apv = {sensor number},{module_position},{apv_position},{first_strip},{num_floating},{side},0,0,0,0,0
#  zon = {sensor number},{zone number},{first strip on p side},{last strip on p side},{first strip on n side},{last strip on n side},0,0,0,0,0
#
# sen defines the sensor proberties:
#  numeration direction can be 0 = from left to right or 1 = from right to left
#	
# apv describes the apvs connected to the sensor
#  module_position and apv_position must be identical to the values in section [mod]
#  first_strip is the strip number bonded to channel 0
#  num_floating is the number of floating strips between two apv channels, set it to 0 if all strips are bonded.
#  side: 0 = the apv is bonded to the n side of the sensor
#        1 = the apv is bonded to the p side of the sensor
#
# zon defines zones of strips with similar properties, e.g.bonding density
#  for each zone the data should be processed separately
#  zone number: this is the number of the zone on one sensor


# module 3
sen = 1,256,0,256,0,0,256,50.0,50.0,90,12750.0 
apv = 1,3,0,0,0,1,0,0,0,0,0
apv = 1,3,1,128,0,1,0,0,0,0,0

zon = 1,1,0,15,0,0,0,0,0,0,0
zon = 1,2,16,31,0,0,0,0,0,0,0
zon = 1,3,32,47,0,0,0,0,0,0,0
zon = 1,4,48,63,0,0,0,0,0,0,0
zon = 1,5,64,79,0,0,0,0,0,0,0
zon = 1,6,80,95,0,0,0,0,0,0,0
... 11 more lines ...
Attachment 5: cern08_silc_mod03_multi6.cfg
# 40 mhz
# multi peak mode (6 sample)
# 50ns peaking time
# 30ns trigger window (built from 5ns window, thus ~12.5ns later)
# NECO
#
# Data processing with FADC+PROC
# SPS Testbeam - single module
# FADC 0  one module at position 3
# FADC 1  not used
#
#
# CI 07 may 2008
#
#
# Lines preceded by a # or ; sign are ignored.
#
# [rem] comments a whole section until the next section start marked by [xxx] .
#

# [vme]
# VME addresses are given in the format
#  {module_name} = {vme_module_number},{vme_address_hex}
#  nec ... NECO module
#  adf ... particular FADC module
#
# Please note that the address ranges are not defined here,
# they are implicitly given by the hardware.
# Module numbers must fill from 0 (this is not checked).
# Please note that no range checking is performed.
# There is no access to VME modules that are not included in this list,

[vme]
nec = 0,0x1a000000

adf = 0,0x1b000000
#adf = 1,0x2b000000

# [nec]
# NECO related information
#  mod = 0|1,{shift_register_delay},{adc_range},{win_delay},{win_length},{dead_time},{time_lat},{max_trg}
#          (default: 0,75,0,50?,900?,36,2,1)
#  res = {list of entries in reset sequence}                (default: 2,4)
#  cal = {list of entries in cal sequence}			(default: 2,3,250,251)
#  sw5 = {list of entries in single cal sequence}		(default: 2,3)
#  str = {list of entries in software trigger sequence}		(default: 75)
#  htr = {list of entries in hardware trigger sequence}		(default: 74)
#
# mod specifies to use either the sequencer (0) or the shift register (1) for hardware trigger and the
#  delay of the shift register (0..255); adc_range (0=1Vpp, 1=2Vpp) -- ignored; win_delay and win_length define
#  the starting point (relative to the APV trigger) and length of the ADC gate in transparent mode; dead_time is
#  the number of 254MHz clock cycles which are set to zero for time measurement after an incoming trigger;
#  time_lat is the latency for time measurement in terms of 40MHz clock cycles; max_trg is the number of incoming
#  triggers which required to activate the veto logic (usually 1; 0 completely disables the veto logic)
# res, cal, sw5, str and htr are containing the bits to set in the 256-element sequencer memory (nothing is set at -1)
# Please note that cal+str together produce a calibration request plus subsequent normal trigger, so the time
#  between them is the latency. sw5 is used to send a single cal request to achieve the correct polarity in
#  case the APV inverter is turned on (this feature only works for entire MAMBOs halves = groups of 3 REBOs)
# 
# These settings are quite fragile! Do not modify until you know exactly what you are doing.

[nec]

# 30m cables, 40mhz, Tp=50ns, single-trigger 
#mod = 0,75,0,70,250,36,2,1
#htr = 61,-1,-1,-1,-1,-1,-1,-1
#str = 100,-1,-1,-1,-1,-1,-1,-1

# TESTBEAM Nov 07, 30m cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
#mod = 0,75,0,70,950,36,2,1
#htr = 59,62,-1,-1,-1,-1,-1,-1
#str = 100,103,-1,-1,-1,-1,-1,-1

# SiLC TESTBEAM June 08, 7m sc cables, 30m repeater cables, 40mhz, Tp=50ns, multi-trigger (6 samples)
mod = 0,75,0,70,950,36,2,1
htr = 61,64,-1,-1,-1,-1,-1,-1
str = 100,103,-1,-1,-1,-1,-1,-1

#common settings
res =  2, 4, -1, -1,-1,-1,-1,-1
cal =  2, 3,250,251,-1,-1,-1,-1
sw5 =  2, 3, -1, -1,-1,-1,-1,-1




# [daq]
# DAQ related specifications are given in the format
#  ads = {N},{search_max_subevents},0,x
#  ini = {initevents},{readout_mode},0,x
#  deh = {module_position},{apv_position},0,x
#  i2t = {N},0,0,x
#  pat = 0,0,0,{data_file_path}
#  clk = {N},{Delay25 frequency range},0,x
#  pdl = {Trigger input delay},0,0,x
#  crd = {crate_number},{clkdel},{trgdel},x
#
# ads N gives the number of samples that are read out from the FIFO1 in transparent mode, search_max_subevents is the
#  maximum number of subevents to search for within one ADC stream (default=1).
# ini: initevents is the number of software triggers in the beginning of a run for pedestal and noise
# evaluation. At the beginning of each run, 2*initevents are generated by software, after that the 
# selected trigger source (hardware, software of calibration) is activated. The initial evaluation
# events are written to disk as normal events are.
# ini: readout_mode defines whether events beyond the initevents are read in raw transparent mode from FIFO1 (0) or
#  in processed mode (1) where only hit information is read from FIFO3
# deh is the APV chip for which single strip histograms are recorded
# i2t is the maximum number of I2C retries in case of failure
# pat specifies the save path for data files (must include a trailing backslash!)
# clk gives the system clock period in integer ns (25 max.) and the frequency range for the Delay25 chip:
#  0...40 MHz, 1...80 MHz, 2...32 MHz, 3...64 MHz
# pdl specifies the delay setting for the trigger input in 0.5ns steps (0..49)
# crd define the global clock and trigger delays between NECO and SVD3_buffer for crates 0 and 1
#  NOTE: clock and trigger is NOT propagated to any crate(s) NOT specified here


[daq]

# TESTBEAM Nov 07
#Standard
#ads = 250,1,0,x

# TESTBEAM Nov 07
#Multitrigger (6)
ads = 950,6,0,x

# RAW (transparent mode) readout
ini = 300,0,0,x

# PROCESSED readout
#ini = 300,1,0,x

deh = 1,0,0,x
i2t = 5,0,0,x
pat = 0,0,0,F:\\testbeam\\cern_jun08\\silc\\data\\

#standard 40mhz clock (25ns)
clk = 25,0,0,x
pdl = 25,0,0,x

#crate distribution delays (set to mid-range to allow adjustments in both directions)
crd = 0,25,25,x

#we don't use crate 1, so we don't set any delay here -> no clock/trigger to crate 1
###crd = 1,25,25,x


# [hit]
# Hit recognition variables are specified here
#  hcs = {hitcut_seed_strip},{hitcut_neighbor_strips}
#  nok = {x.x},0
#  
#
# hcs gives seed and neighbor hit cuts in units of strip sigma
# nok states the threshold over average noise at which strips are excluded from further analysis (to exclude noisy strips)

[hit]
# si sensor
hcs = 4.0,4.0

# do not exclude strips
nok = 2000.0,0


# [cal]
# Calibration related data
#  lvl = {level},0
#  lat = {latbeg},{latend}
#  sam = {average_samples},{number of samples in 6-tuple mode}
#  grp = {number_of_groups},0
#  lg6 = {latency},{group}
#  lv6 = {startlevel},{endlevel}
#
# lvl is the CLVL amplitude (0..255), 1 is 625e-, 36 is 1 MIP (22500e-) nominally, in reality 26 is 1 MIP
# lat is the Latency range to cover (latend-latbeg>=2, latend-latbeg<=15)
# sam is the number of samples to average per position for normal and 6-tuple modes
# grp is how many groups to scan (<=8), first group is strips 0,8,16,..., second group is 1,9,17,..., ...
# lg6 defines the latency in 6-tuple mode and which group to observe in that mode
# lv6 defines the scan range of amplitude in 6-tuple mode

[cal]
#real 1 MIP level (22400e)
lvl = 26,0

#real 5 MIPs level
#lvl = 130,0

#LAT=95/98 Calibration (short display)
#lat = 89,100

#LAT=95/98 Calibration (short display for >=50mhz)
#lat = 81,98

#LAT=95/98 Calibration (long peak mode tail display)
lat = 75,100

#common settings
sam = 50,150
grp = 8,0

#6-tuple mode settings
lg6 = 97, 1
#lv6 =  1,95
lv6 =  50,52




# [i2c]
# This section defines one or more I2C sets for the APV25. In the [mod] section, those sets are referenced to by their number.
#  ia2 = {number},{mode},{lat},{ipre},{ipcasc},{ipsf},{isha},{issf},{ipsp},{imuxin},{vfp},{vfs},{vpsp},{muxgain}
#
# The I2C settings must be individually numbered (ascending from 0). The easiest case is to use the same
# settings for all chips of one type, but one could go so far to use separate settings for each chip.
# vadj/vpsp is set individually for each apv in the [mod] section, the value specified here is meaningless.

[i2c]

# apv25s1, peak, inverter ON, Tp=50ns, (p side)
#ia2 =          0,    63,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, peak, inverter OFF, Tp=50ns, (n side)
#ia2 =          1,    31,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# apv25s1, multi-peak, inverter ON, Tp=50ns, (p side)
ia2 =          0,    61,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4

# apv25s1, multi-peak, inverter OFF, Tp=50ns, (n side)
ia2 =          1,    29,   95,    98,      52,    34,    34,    34,    55,      34,   30,   60,     0,       4


# [mod]
# Detector module (actually hybrid) specifications are given in the format
#  mod = {module_position},{crate_number},{mambo_number},{rebo_number},{hybrid_number},m,{AD8128_peak},{rebo_clkdelay},{rebo_trgdelay},0,0,0,0,{Name}
#  apv = {module_position},{apv_position},{i2c_address},{i2c_settings},{vadj/vpsp},x,0,0,{fadc_offset},{fadc_number},{fadc_channel},{fadc_clkdelay [0..49]},{AD8128_gain},x
#
# mod gives the hybrid/module properties: The position counts from 0 to 7 in beam direction,
#  Name must not contain blanks ("_" is allowed).
# apv describes the chips located on a hybrid 
#  and the ADC channel where they are read out, either a Vienna ADC (a) or a FED (f).
# The ADC offset is only available with the Vienna ADCs and shifts the baseline.
# The individual chip vadj setting dominates over the [i2c] setting.


[mod]

# module 3
mod = 3,0,0,2,3,m,45,25,0,0,0,0,0, 3_SiLC_04/04
apv = 3,0,36,0,30,x,0,0,5,0,13,12,100,x
apv = 3,1,38,0,30,x,0,0,5,0,14,14,100,x


# [bad]
# Bad channels description table
#  bad = {module_position},{apv_position},{List of 18 strip values or -1}
#
# Maps bad channels, which are then excluded from hit search. Up to 18 bad strips can be entered per line,
# more lines per APV are allowed. Unused values in the list must be filled with -1

[bad]
#bad = 2,0,73,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1,-1

[sen]
# sensor configuration
#  sen = {sensor number},{number strips on p side},{numeration direction p},{number strips on n side},{numeration direction n},{first_full},{last_full},{pitch p [µm]}, {pitch n [µm]},{angle [°]},{height [µm]}
#  apv = {sensor number},{module_position},{apv_position},{first_strip},{num_floating},{side},0,0,0,0,0
#  zon = {sensor number},{zone number},{first strip on p side},{last strip on p side},{first strip on n side},{last strip on n side},0,0,0,0,0
#
# sen defines the sensor proberties:
#  numeration direction can be 0 = from left to right or 1 = from right to left
#	
# apv describes the apvs connected to the sensor
#  module_position and apv_position must be identical to the values in section [mod]
#  first_strip is the strip number bonded to channel 0
#  num_floating is the number of floating strips between two apv channels, set it to 0 if all strips are bonded.
#  side: 0 = the apv is bonded to the n side of the sensor
#        1 = the apv is bonded to the p side of the sensor
#
# zon defines zones of strips with similar properties, e.g.bonding density
#  for each zone the data should be processed separately
#  zone number: this is the number of the zone on one sensor

# module 3
sen = 1,256,0,256,0,0,256,50.0,50.0,90,12750.0 
apv = 1,3,0,0,0,1,0,0,0,0,0
apv = 1,3,1,128,0,1,0,0,0,0,0

zon = 1,1,0,15,0,0,0,0,0,0,0
zon = 1,2,16,31,0,0,0,0,0,0,0
zon = 1,3,32,47,0,0,0,0,0,0,0
zon = 1,4,48,63,0,0,0,0,0,0,0
zon = 1,5,64,79,0,0,0,0,0,0,0
zon = 1,6,80,95,0,0,0,0,0,0,0
zon = 1,7,96,111,0,0,0,0,0,0,0
zon = 1,8,112,127,0,0,0,0,0,0,0
zon = 1,9,128,143,0,0,0,0,0,0,0
zon = 1,10,144,159,0,0,0,0,0,0,0
zon = 1,11,160,175,0,0,0,0,0,0,0
zon = 1,12,176,191,0,0,0,0,0,0,0
zon = 1,13,192,207,0,0,0,0,0,0,0
... 5 more lines ...
  12   Fri May 30 10:36:18 2008 Marko DragicevicotherImportant Information/Contact    
IPs
Linksys Router
  • external: routerhephy.cern.ch (137.138.171.102)
  • internal: 192.168.1.1
    US&ER /PA_SS'WD: admin/sensor
  • WLAN-SSID: HEPHY
  • WLAN-WPA-TKIP: testbeam08

EUDETMAC
  • external: eudetmac001.cern.ch
  • U1SE*R/P*AS§S/WD (ssh): eudet/gsigsi
  • from EUDETMAC to TLU:
    ssh tlupc

LAB2PC (APVDAQ, DUT HV)
  • internal: 192.168.1.10
  • external VNC: routerhephy.cern.ch (137.138.171.102:5900)
    pa2s2s2w2d: hephy

XY Table
  • internal VNC: 192.168.1.11
    pa2s2s2w2d: hephy

Beam Control PC
  • external VNC: CWO-HNA453-H6B1.CERN.CH (137.138.61.206)

Phone
Vienna CERN Mobile Phone (usually Thomas Bergauer)
  • 162471

Daniel Haas
  • 165423

Marko Dragicevic
  • Hostel (39-120): 79 120
  • Private: +43 650 4243343

Markus Friedl
  • Hostel (41-107): 60 107
  • Private: +43 699 17251085

Thomas Bergauer
  • Hostel (39-220): 79 220
  • Private: +43 664 3769400 (switched off during testbeam)

Christian Irmler
  • Hostel (41-222): 60 222
  • Private: +43 699 19437327

Misc
SPS Page 1

Path to start cesar
  15   Sat May 31 13:34:28 2008 Thomas Bergauer how to copy data from lab2pc to eudetmac    
rsync -rltvz --exclude "data_vie" --exclude "hitfit_cern08" --exclude "output_vie" --exclude "run2719*" --rsh="ssh -C -p222" friedl@routerhephy.cern.ch:/cygdrive/f/testbeam/cern_jun08/ /Volumes/Data/eudet/APVDAQ/

but replace run2719 with the name of the run file currently active (data taking)

and use Markus' password
  19   Sat May 31 18:33:50 2008 Thomas Bergauerotherbeam profile    
Beam configuration
Beam configuration file: H6b.802 (FM HAD (P0 off, H8=+180) PARLALLEL IN H6B SILC 2008

Rate: 5.7E5 particles/spill (measured with SCINT8 in beamline)

Particle Production Applet
Calculator applet

For +120 Gev/c beam:

Pi+55.67 %
p38.95 %
K+ 5.38 %
Attachment 1: Picture_1.png
Picture_1.png
Attachment 2: beamline_settings.png
beamline_settings.png
  29   Sun Jun 1 17:01:12 2008 Thomas BergauerSiLCpath do data    
The data of all runs are stored on eudetmac001.cern.ch:

APVDAQ: /Volumes/Data/eudet/APVDAQ/silc/data

Telescope data: /Volumes/Data/eudet/Data/testing

all data will be saved to an external Firewire disk (Vienna Backup) and to CASTOR
  30   Sun Jun 1 18:23:38 2008 Markus FriedlSiLCVery simple trackingrun2719100000  
Very simple alignment (manual linear x direction shifting only, no rotation, assuming equal z spacing) and tracking.
Reference plane = Module 3 (~center)
Deviation calculated from track prediction using the other layers.
Simple Center-of-gravity algorithm (as of APVDAQ_Analysis), no eta applied.
Using only events which have exactly 1 hit per plane (~80% of all events).

Results: 
 Residual RMS = 4.99 um (REFERENCE against neighbor layers 2+4 only)
 Residual RMS = 6.35 um (REFERENCE against all 7 other layers) -> needs more sophisticated alignment
Attachment 1: silc_verysimple_res_2REF4.png
silc_verysimple_res_2REF4.png
Attachment 2: silc_verysimple_res_012REF4567.png
silc_verysimple_res_012REF4567.png
  31   Sun Jun 1 20:13:37 2008 Eudet TelescopeSiLCBZIP2 compressed APVDAQ data    
Processed APVDAQ data_cluster - in tar.bzip2 format:

- on machine: eudetmac001.cern.ch
- in directory: /Volumes/Data/eudet/APVDAQ/silc/data_bz2
- size reduction by factor 6
- in order to extract files, write: tar -xjf name.tar.bz2

Zbynek
  34   Sun Jun 1 23:36:21 2008 Christian IrmlerSiLCHowTo analyse data    
The analysis consists of two stages:
  • The first is zero supression an cluster finding done with "apvdaq_analysis_fadc" (Labwindows/CVI application)
  • The second stage is hit time reconstruction done with ROOT. (hitfit)
Both are installed on EUDETMAC.

apvdaq_analysis_fadc:
  • start apvdaq_analysis_fadc within the virtal Windows XP machine (parallels).
  • select a runfile, e.g. run0001.dat
  • select a propper calibration file, default is "cal002.out"
  • select pedestal correction file, default is "pedcorr001.ped"
  • enable "generate hit file and save results"
  • click "Start"

  • The result of the analyis is a file containing all hits above threshold, the filename is "xxxxxxx_cluster.hit", where xxxxxxx is the run name
  • The data structure of the file is described at http://elog.hephy.at/testbeam-SPS08/04
  • The file is located in the same folder as the raw data file (= data)


hitfit:
  • Once apvdaq_analysis_fadc is finished, start a console window and change into the directory /Volumes/Data/eudet/APVDAQ
  • execute ./hitfitrun nnnn, where nnnn is the run number

  • results: file with fitted hits (data structure see http://elog.hephy.at/testbeam-SPS08/04) as well as several plots.
  • file name: xxxxxxx_cluster.hit.fit, the file is located in the subdirectory output.
Attachment 1: analysis_howto.jpg
analysis_howto.jpg
  59   Tue Jun 3 12:41:22 2008 Eudet Telescope useful eudaq software commands(work in progress)   
to show information about a run (number of events, start and end timestamp,....:
./TestReader.exe -b -e 2828
  67   Wed Jun 4 15:41:04 2008 Thomas Bergauer end.    
testbeam is over. DUTs and APVDAQ have been dismounted and will be shipped back to Vienna. EUDET telescope is still in H6B and taking data for alignment and pedestal during the night.
  68   Tue Jun 17 09:43:07 2008 Thomas Bergauer Data analysis progressoverview (in progress)   
run numberWhat?APVDAQ modeTelescope mode#eventshit data processedhitfit processed
0001first attemptrawn.a.51803yesyes
0002LEFT poszsn.a.100kyesyes
0003MID poszsn.a.100kyesyes
0004RIGHT poszsn.a.100kyesyes
2716all sc onrawzs 20000 yesyes
2717wrong posrawzs 6490 nono
2718RIGHT posrawzs100kyesyes
2719MID posrawzs100kyesyes
2720LEFT posrawzs100kyesyes
2721LEFT posrawraw (-2737)22kyesyes
2738telescope pedestal
2739crap
2741MID posrawraw (-2757)22kyesyes
2758RIGHT posrawraw (-2783)34873yesyes
2784-2786telescope something
2787HV=100rawzs30kyesyes
2788HV=10rawzs10kyesyes
2789HV=20rawzs10kyesyes
2790HV=30rawzs10kyesyes
2791HV=40rawzs10kyesyes
2792HV=50rawzs4536yesyes
2821HV=50rawzs10kyesyes
2822HV=60rawzs10kyesyes
2823HV=70rawzs10kyesyes
2824HV=80rawzs10kyesyes
2825HV=90rawzs10kyesyes
2826HV=120rawzs10kyesyes
2827HV=150rawzs10kyesyes
2828HV=200rawzs10kyesyes
2831angle=10degrawzs10kyes yes
2832angle=20degrawzs10kyes yes
2833angle=30degrawzs10kyes yes
2834angle=40degrawzs10kyes yes
2835angle=50degrawzs10kyes yes
2836angle=60degrawzs10kyes yes
2837angle=0degrawzs20kyes yes
28382-dimensional DUTsrawzs478159yes in progress
Attachment 1: Testbeam_CERN_08.xls
ELOG V3.1.5-fc6679b