Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 5 of 7  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events XYPositionup Cooling Data
  107   Mon Apr 17 17:02:34 2017 Axel KoenigALiBaVa (IFX)run_003_HPK_CB_200V.dat003250000107, 2.6, 230NoUnknown

Remarks: Telescope run 606. Angle scan.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_003_HPK_CB_200V.dat
Telescope run 606
Triggers 250000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -200
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

230 deg

  109   Mon Apr 17 17:46:38 2017 Axel KoenigALiBaVa (IFX)run_005_HPK_CB_50V.dat005150000107, 2.6, 240NoUnknown

Remarks: Telescope run 609. Bias scan 50 V. Bias scan.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_005_HPK_CB_50V.dat
Telescope run 609
Triggers 150000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -50
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  111   Mon Apr 17 19:19:14 2017 Axel KoenigALiBaVa (IFX)run_006_HPK_CB_100V.dat006150000107, 2.6, 240NoUnknown

Remarks: Telescope run 610. Bias scan 100 V. Bias scan.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_006_HPK_CB_100V.dat
Telescope run 610
Triggers 150000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  113   Mon Apr 17 19:54:08 2017 Axel KoenigALiBaVa (IFX)run_007_HPK_CB_150V.dat007300000107, 2.6, 240NoUnknown

Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_007_HPK_CB_150V.dat
Telescope run 611
Triggers 300000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -150
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  114   Mon Apr 17 21:52:45 2017 Axel KoenigALiBaVa (IFX)run_008_HPK_CB_250V.dat008150000107, 2.6, 240NoUnknown

Remarks: Telescope run 613. Bias scan 250 V.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_008_HPK_CB_250V.dat
Telescope run 613
Triggers 150000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -250
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  115   Mon Apr 17 22:27:44 2017 Axel KoenigALiBaVa (IFX)run_009_HPK_CB_200V.dat0092400000107, 2.6, 240NoUnknown

Remarks: Telescope run 614. Long run over night. run crashed over night!

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_009_HPK_CB_200V.dat
Telescope run 614
Triggers 2400000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -200
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  119   Tue Apr 18 08:07:15 2017 Axel KoenigALiBaVa (IFX)run_010_HPK_CB_200V.dat010350000107, 2.6, 240NoUnknown

Remarks: Telescope run 616. Short run central position. Repeated due to crash over night.

No beam during run.Only ~10000 events.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_010_HPK_CB_200V.dat
Telescope run 616
Triggers 350000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -200
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

240 deg

  118   Tue Apr 18 08:04:39 2017 Axel KoenigALiBaVa (IFX)run_004_HPK_CB_200V.dat004250000107, 2.6, 250NoUnknown

Remarks: Telescope run 607. Angle scan.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_004_HPK_CB_200V.dat
Telescope run 607
Triggers 250000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -200
Latency 132
Table x 107 mm
Table z 2.6 mm
Tabe rot

250 deg

  106   Mon Apr 17 16:36:56 2017 Axel KoenigALiBaVa (IFX)run_002_HPK_CB_200V.dat002450000107, 5.8, 240NoUnknown

Remarks: Telescope run 605. Bias scan 200 V. Only one chip.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_002_HPK_CB_200V.dat
Telescope run 605
Triggers 450000
Alibava trigger eff. ~64%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -200
Latency 132
Table x 107 mm
Table z 5.8 mm
Tabe rot

240 deg

  68   Fri Apr 14 14:49:09 2017 Axel KoenigALiBaVa (IFX)run_023_IFX_CB_100V.dat023385000109, 0, 240NoCrap

Remarks: Telescope run 546. Bias voltage 100 V. Beam position on only one chip. Run destroyed. Intended trigger count 500k

Parameter Value
Alibava run run_023_IFX_CB_100V.dat
Telescope run 546
Triggers 385000
Alibava trigger eff ~62 %
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100 V
Latency 132
Table x 109 mm
table z 0 mm
table rot 240 deg (parallel to tele. planes)
  4   Wed Apr 12 22:34:18 2017 Axel KönigALiBaVa (IFX)run_002_IFX_CB_100V.dat002100000109, 0.5, 240NoUnknown

Remarks: Beam position on only one chip.

Parameter Value
Alibava run run_002_IFX_CB_100V.dat
Telescope run 498
triggers 100000
Alibava trigger eff. ?
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100 V
Latency 132
Table x 109 mm
Table z 0.5 mm
Table rot 240 deg (parallel to tele. planes)
  65   Fri Apr 14 13:06:30 2017 Axel KoenigALiBaVa (IFX)run_022_IFX_CB_100V.dat022500000109, 10.5, 240NoUnknown

Remarks: Telescope run 545. Bias voltage 100 V. Beam position on only one chip.

Parameter Value
Alibava run run_022_IFX_CB_100V.dat
Telescope run 545
Triggers 500000
Alibava trigger eff ~62 %
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100 V
Latency 132
Table x 109 mm
table z 10.5 mm
table rot 240 deg (parallel to tele. planes)
  70   Fri Apr 14 18:22:58 2017 Axel KoenigALiBaVa (IFX)run_026_IFX_CB_100V.dat026350000109, 4.5, 230NoUnknown

Remarks: Telescope run 549. Angle shift 230 deg.

Parameter Value
Alibava run run_026_IFX_CB_100V.dat
Telescope run 549
Triggers 350000
Alibava trigger eff. ~59.8%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

230 deg

  1   Wed Apr 12 21:06:44 2017 Axel KönigALiBaVa (IFX)run_001_IFX_CB_100V.dat001200000109, 4.5, 240NoUnknown

First run for alibava modules with Sensor IFX_CB.

Beam energy = 5.6 GeV

Telescope threshold = 6

Telescope data file = 496

Bias voltage = -100V

Telescope synchornisation: yes

Position table (is center of sensor):

x=109mm

y=4.5mm

phi=240 deg

 

Attachment 1: 11.png
11.png
Attachment 2: 46.png
46.png
  8   Thu Apr 13 09:23:20 2017 Axel KönigALiBaVa (IFX)run_005_IFX_CB_10V.dat005285000109, 4.5, 240NoUnknown

Remarks: Telescope run 508. Bias scan 10 V.

Parameter Value
Alibava run run_005_IFX_CB_10V.dat
Telescope run 508
Triggers 285000
Alibava trigger eff. ~36.5%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -10
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  9   Thu Apr 13 10:03:29 2017 Axel KönigALiBaVa (IFX)run_001_IFX_CB_100V.dat001200000109, 4.5, 240NoUnknown

Remarks: Telescope run 496. Bias voltage 100 V. First run at DESY TB.

Parameter Value
Alibava run run_001_IFX_CB_100V.dat
Telescope run 496
Triggers 200000
Alibava trigger eff. ?
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  10   Thu Apr 13 10:58:57 2017 Axel KoenigALiBaVa (IFX)run_006_IFX_CB_20V.dat006185000109, 4.5, 240NoUnknown

Remarks: Telescope run 510. Bias scan 20 V.

Parameter Value
Alibava run run_006_IFX_CB_10V.dat
Telescope run 510
Triggers 185000
Alibava trigger eff. ~55.6%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -20
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  11   Thu Apr 13 11:25:32 2017 Axel KoenigALiBaVa (IFX)run_007_IFX_CB_30V.dat007170000109, 4.5, 240NoUnknown

Remarks: Telescope run 513. Bias scan 30 V.

Parameter Value
Alibava run run_007_IFX_CB_30V.dat
Telescope run 513
Triggers 170000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -30
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  12   Thu Apr 13 12:00:40 2017 Axel KoenigALiBaVa (IFX)run_008_IFX_CB_40V.dat008175000109, 4.5, 240NoUnknown

Remarks: Telescope run 515. Bias scan 40 V.

Parameter Value
Alibava run run_008_IFX_CB_40V.dat
Telescope run 515
Triggers 175000
Alibava trigger eff. ~58%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -40
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  13   Thu Apr 13 12:33:20 2017 Axel KoenigALiBaVa (IFX)run_009_IFX_CB_50V.dat009175000109, 4.5, 240NoUnknown

Remarks: Telescope run 517. Bias scan 50 V.

Parameter Value
Alibava run run_009_IFX_CB_50V.dat
Telescope run 517
Triggers 175000
Alibava trigger eff. ~58%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -50
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

ELOG V3.1.5-fc6679b