ID Date Author Project Subject Run Number Events XYPosition Coolingdown Data Text Attachments
  66   Fri Apr 14 13:21:07 2017 Johannes GrossmannMaPSAAlignment Check662500000NoUnknownTelescope 1318

Threshold 100

Mapsa CLK Delay 0
  
  67   Fri Apr 14 14:21:35 2017 Axel KoenigcommonRun summary IFX_CB    NoUnknown


Alibava
  
  68   Fri Apr 14 14:49:09 2017 Axel KoenigALiBaVa (IFX)run_023_IFX_CB_100V.dat023385000109, 0, 240NoCrapRemarks: Telescope run 546. Bias voltage
100 V. Beam position on only one chip. Run
destroyed. Intended trigger count 500k
  
  69   Fri Apr 14 17:22:52 2017 Axel KoenigALiBaVa (IFX)run_025_IFX_CB_150V.dat025175000109, 4.5, 240NoUnknown3Remarks: Telescope run 548. Bias scan
150 V.

  
  70   Fri Apr 14 18:22:58 2017 Axel KoenigALiBaVa (IFX)run_026_IFX_CB_100V.dat026350000109, 4.5, 230NoUnknownRemarks: Telescope run 549. Angle shift
230 deg.

  
  71   Fri Apr 14 19:43:13 2017 Axel KoenigALiBaVa (IFX)run_027_IFX_CB_100V.dat027350000109, 4.5, 250NoUnknownRemarks: Telescope run 550. Angle shift
250 deg.

  
  72   Fri Apr 14 21:11:18 2017 Axel KoenigALiBaVa (IFX)run_028_IFX_CB_100V.dat0283000000109, 4.5, 240NoCrapRemarks: Telescope run 551. Longrun over
night. Run crashed. Events only up to 2288000
valid.
  
  73   Sat Apr 15 09:57:51 2017 Axel KoenigALiBaVa (IFX)run_029_IFX_CB_130V.dat029175000109, 4.5, 240NoUnknown3Remarks: Telescope run 557. Bias scan
130 V.

  
  74   Sat Apr 15 12:12:00 2017 Axel KoenigALiBaVa (IFX)run_030_IFX_CB_100V.dat0301000000109, 4.5, 240NoUnknown3Remarks: Telescope run 558. Bias scan
100 V. Telescope chiller turned off. Could
be the root cause of crashing runs.
  
  75   Sat Apr 15 16:52:06 2017 Axel KoenigALiBaVa (IFX)run_001_Baby_100V.dat001250000102.5, 22.5, 240NoUnknownRemarks: Telescope run 562. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  76   Sat Apr 15 16:55:19 2017 Axel KoenigcommonChiller turned off!   NoUnknownThe chiller has been turned off beginning
of run_30_IFX_CB_100V.dat.

Set temperature was 15 C. Now it
  
  77   Sat Apr 15 17:38:58 2017 Axel KoenigALiBaVa (IFX)run_002_Baby_100V.dat002250000102.5, 12.5, 240NoUnknownRemarks: Telescope run 563. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  78   Sat Apr 15 18:31:14 2017 Axel KoenigALiBaVa (IFX)run_003_Baby_100V.dat003250000102.5, 32.5, 240NoUnknownRemarks: Telescope run 564. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  79   Sat Apr 15 19:20:34 2017 Axel KoenigALiBaVa (IFX)run_004_Baby_100V.dat004250000102.5, 22.5, 250NoUnknownRemarks: Telescope run 565. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  80   Sat Apr 15 20:12:41 2017 Axel KoenigALiBaVa (IFX)run_005_Baby_100V.dat005250000102.5, 22.5, 230NoUnknownRemarks: Telescope run 568. Telescope chiller
turned off (could be the root cause of runs
crashing).
  
  81   Sat Apr 15 21:18:26 2017 Axel KoenigALiBaVa (IFX)run_007_Baby_10V.dat007450000102.5, 22.5, 240NoCrapRemarks: Telescope run 579. Bias scan 10
V. run crashed. Data vaild up to 274915.

Telescope chiller turned off (could
  
  82   Sun Apr 16 13:15:55 2017 Axel KoenigALiBaVa (IFX)run_008_Baby_20V.dat008175000102.5, 22.5, 240NoUnknownRemarks: Telescope run 583. Bias scan 20
V. run crashed.

Telescope chiller turned off (could
  
  83   Sun Apr 16 15:44:35 2017 Axel KoenigALiBaVa (IFX)run_009_Baby_30V.dat009135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 586. Bias scan 30
V.

Telescope chiller turned off (could
  
  84   Sun Apr 16 17:42:06 2017 Axel KoenigALiBaVa (IFX)run_010_Baby_40V.dat010135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 587. Bias scan 40
V.

Telescope chiller turned off (could
  
  85   Sun Apr 16 18:25:59 2017 Axel KoenigALiBaVa (IFX)run_011_Baby_50V.dat011135000102.5, 22.5, 240NoUnknownRemarks: Telescope run 588. Bias scan 50
V.

Telescope chiller turned off (could
  