Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 6 of 7  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events XYPosition Coolingdown Data Text Attachments
  108   Mon Apr 17 17:25:24 2017 Axel KoenigcommonTelescope geometry ALiBaVa   NoUnknownThe plane distances are measured at the
center of the planes.

The distance of the DUT to the
 IMG_1522.JPGbeam.pdfbeam1.pdfbeam2.pdf 
  109   Mon Apr 17 17:46:38 2017 Axel KoenigALiBaVa (IFX)run_005_HPK_CB_50V.dat005150000107, 2.6, 240NoUnknownRemarks: Telescope run 609. Bias scan 50
V. Bias scan.

Telescope chiller turned off (could
  
  110   Mon Apr 17 17:55:55 2017 Johannes GrossmannMaPSAHV_Scan48800NoUnknownChanged HV from 120 V to 90 V

17:53 17.4.2017
  
  111   Mon Apr 17 19:19:14 2017 Axel KoenigALiBaVa (IFX)run_006_HPK_CB_100V.dat006150000107, 2.6, 240NoUnknownRemarks: Telescope run 610. Bias scan 100
V. Bias scan.

Telescope chiller turned off (could
  
  113   Mon Apr 17 19:54:08 2017 Axel KoenigALiBaVa (IFX)run_007_HPK_CB_150V.dat007300000107, 2.6, 240NoUnknownRemarks: Telescope run 611. Bias scan 150
V. Bias scan. Run crashed at 294000 triggers!

Telescope chiller turned off (could
  
  114   Mon Apr 17 21:52:45 2017 Axel KoenigALiBaVa (IFX)run_008_HPK_CB_250V.dat008150000107, 2.6, 240NoUnknownRemarks: Telescope run 613. Bias scan 250
V.

Telescope chiller turned off (could
  
  115   Mon Apr 17 22:27:44 2017 Axel KoenigALiBaVa (IFX)run_009_HPK_CB_200V.dat0092400000107, 2.6, 240NoUnknownRemarks: Telescope run 614. Long run over
night. run crashed over night!

Telescope chiller turned off (could
  
  116   Mon Apr 17 23:50:59 2017 Johannes GrossmannMaPSAHV_Scan52200NoUnknownChanged HV from 90 V to 80 V

Kann ich wegwerfen!

23:49 17.4.2017
  
  117   Mon Apr 17 23:52:47 2017 Johannes GrossmannMaPSAHV_Scan52300NoUnknownChanged HV 80 V

23:50 17.4.2017
  
  118   Tue Apr 18 08:04:39 2017 Axel KoenigALiBaVa (IFX)run_004_HPK_CB_200V.dat004250000107, 2.6, 250NoUnknownRemarks: Telescope run 607. Angle scan.

Telescope chiller turned off (could
be the root cause of runs crashing).
  
  119   Tue Apr 18 08:07:15 2017 Axel KoenigALiBaVa (IFX)run_010_HPK_CB_200V.dat010350000107, 2.6, 240NoUnknownRemarks: Telescope run 616. Short run central
position. Repeated due to crash over night.

No beam during run.Only ~10000
  
  120   Tue Apr 18 16:16:59 2017 Johannes GrossmannMaPSAStd Settings60400NoUnknownChanged HV 100 V Threshold 75

16:14 17.4.2017

Telescope Runnumber 1855
  
  Draft   Tue Apr 18 17:55:19 2017 Axel KoenigcommonRun summary HPK_CB   NoUnknown


Alibava
  
  122   Tue Apr 18 17:56:37 2017 Axel KoenigcommonRun summary HPK_CB   NoUnknown


Alibava
  
  123   Tue Apr 18 18:19:33 2017 Axel KoenigALiBaVa (IFX)run_001_double_irrad_100V.dat001350000111, 1, 240NoUnknownRemarks: Telescope run 620. 2nd chip only.
Central position.

Telescope chiller turned on!
  
  124   Tue Apr 18 18:48:27 2017 Axel KoenigALiBaVa (IFX)run_002_double_irrad_100V.dat00270000094, 1, 240NoUnknownRemarks: Telescope run 623. 1nd chip only.
Central position.

Telescope chiller turned on!
  
  125   Tue Apr 18 21:03:42 2017 Axel KoenigALiBaVa (IFX)run_003_double_irrad_100V.dat0033500000103, 1, 240NoUnknownRemarks: Telescope run 625. Both chips.
Central position. Run crashed over night.

Collected triggers 2710991.
  
  126   Tue Apr 18 21:55:44 2017 Johannes GrossmannMaPSARotation63500NoUnknownHV 100 V Threshold 75 Winkel 15

16:14 17.4.2017

Telescope Runnumber 1887
  
  127   Wed Apr 19 17:31:43 2017 Axel KoenigALiBaVa (IFX)run_001_Irrad_100V.dat00140000096, 64, 360NoUnknownRemarks: Telescope run 628. Bias scan -100V,
central position of sensor (DUT parallel
to telescope planes at 360 deg due to different
  
  128   Wed Apr 19 19:27:38 2017 Axel KoenigALiBaVa (IFX)run_002_Irrad_200V.dat00240000096, 64, 360NoUnknownRemarks: Telescope run 630. Bias scan -200V,
central position of sensor (DUT parallel
to telescope planes at 360 deg due to different
  
ELOG V3.1.5-fc6679b