| Alibava run | 
			Telescope run | 
			File existence check | 
			Run type | 
			Triggers | 
			Remarks | 
		
		
			| 001 | 
			496 | 
			yes | 
			position check | 
			200000 | 
			none | 
		
		
			| 002 | 
			498 | 
			yes | 
			beam focused on one strip segment only | 
			100000 | 
			none | 
		
		
			| 003 | 
			500 | 
			yes | 
			beam focused on one strip segment only | 
			100000 | 
			none | 
		
		
			| 005 | 
			508 | 
			yes | 
			Bias scan. Voltage = 10 V | 
			285000 | 
			none | 
		
		
			| 006 | 
			510 | 
			yes | 
			Bias scan. Voltage = 20 V | 
			185000 | 
			none | 
		
		
			| 007 | 
			513 | 
			yes | 
			Bias scan. Voltage = 30 V | 
			170000 | 
			none | 
		
		
			| 008 | 
			515 | 
			yes | 
			Bias scan. Voltage = 40 V | 
			175000 | 
			none | 
		
		
			| 009 | 
			517 | 
			yes | 
			Bias scan. Voltage = 50 V | 
			175000 | 
			none | 
		
		
			| 010 | 
			521 | 
			yes | 
			Bias scan. Voltage = 60 V | 
			175000 | 
			none | 
		
		
			| 011 | 
			522 | 
			yes | 
			Bias scan. Voltage = 65 V | 
			175000 | 
			none | 
		
		
			| 012 | 
			523 | 
			yes | 
			Bias scan. Voltage = 70 V | 
			175000 | 
			none | 
		
		
			| 013 | 
			524 | 
			yes | 
			Bias scan. Voltage = 75 V | 
			175000 | 
			none | 
		
		
			| 014 | 
			525 | 
			yes | 
			Bias scan. Voltage = 80 V | 
			175000 | 
			none | 
		
		
			| 015 | 
			526 | 
			yes | 
			Bias scan. Voltage = 90 V | 
			175000 | 
			none | 
		
		
			| 016 | 
			527-531 | 
			yes | 
			Bias scan. Voltage = 100 V | 
			750000 | 
			Telescope files 527 to 531, run crashed! | 
		
		
			| 017 | 
			532 | 
			yes | 
			Bias scan. Voltage = 110 V | 
			175000 | 
			none | 
		
		
			| 018 | 
			533 | 
			yes | 
			Bias scan. Voltage = 120 V | 
			175000 | 
			none | 
		
		
			| 020 | 
			535 | 
			yes | 
			overnight run at 100 V | 
			190000 | 
			run crashed data may be corrupted | 
		
		
			| 021 | 
			540 | 
			yes | 
			CRAP! | 
			? | 
			CRAP! | 
		
		
			| 022 | 
			545 | 
			yes | 
			beam focused on one strip segment only | 
			500000 | 
			none | 
		
		
			| 023 | 
			546 | 
			yes | 
			beam focused on one strip segment only | 
			385000 | 
			run crashed data may be corrupted | 
		
		
			| 024 | 
			547 | 
			yes | 
			Bias scan. Voltage = 140 V | 
			175000 | 
			none | 
		
		
			| 025 | 
			548 | 
			yes | 
			Bias scan. Voltage = 150 V | 
			175000 | 
			none | 
		
		
			| 026 | 
			549 | 
			yes | 
			Rotation -10 deg | 
			350000 | 
			none | 
		
		
			| 027 | 
			550 | 
			yes | 
			Rotation +10 deg | 
			350000 | 
			none | 
		
		
			| 028 | 
			551 | 
			yes | 
			overnight run at 100 V | 
			3000000 | 
			run crashed data may be corrupted | 
		
		
			| 029 | 
			557 | 
			yes | 
			Bias scan. Voltage = 130 V | 
			175000 | 
			none | 
		
		
			| 030 | 
			558 | 
			yes | 
			long run | 
			1000000 | 
			telescope chiller turned off (keept at this state unless otherwisde stated |