67
|
Mon Nov 30 22:35:41 2015 |
Hao Yin | Belle II | system | Hardware_Room_With_Cold_I2C | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
ADC shifted by 9 (4.5ns) all sensors |
|
|
65
|
Mon Nov 30 20:27:42 2015 |
Hao Yin | Belle II | system | Hardware_Room_With_Cold_I2C | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
ADC shifted by 5 (2.5ns) all sensors |
|
|
64
|
Mon Nov 30 20:16:37 2015 |
Hao Yin | Belle II | system | Hardware_Room_With_Cold_I2C | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
ADC delay shifted by 3 (1.5ns) |
|
|
63
|
Mon Nov 30 20:06:15 2015 |
Hao Yin | Belle II | system | Hardware_Room_With_Cold_I2C | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
with room temp i2c config |
|
|
62
|
Mon Nov 30 19:48:05 2015 |
Hao Yin | Belle II | system | Hardware_Room_With_Cold_I2C | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
with room temp i2c config |
|
|
61
|
Mon Nov 30 19:01:54 2015 |
Hao Yin | Belle II | system | Hardware_Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
Temp = 0°C |
|
|
60
|
Mon Nov 30 18:49:23 2015 |
Hao Yin | Belle II | system | Hardware_Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
target: -Z |
|
|
59
|
Mon Nov 30 18:45:49 2015 |
Hao Yin | Belle II | system | PedestalRun_Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns), FIRRun_Cold_001
|
|
|
58
|
Mon Nov 30 18:44:04 2015 |
Hao Yin | Belle II | system | FIRRun_Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns)
|
|
|
57
|
Mon Nov 30 18:32:13 2015 |
Hao Yin | Belle II | system | ADC Delay Scan Cold | | ADC Cold diff to hot: 1-3 adc delay config
(max 1.5 ns) |
|
|
56
|
Mon Nov 30 17:47:54 2015 |
Hao Yin | Belle II | system | HardwareRun002 | | ADC Hot, FIRRun001, PedestalRun001
target: -Z
room temp pedrun |
|
|
55
|
Mon Nov 30 17:23:51 2015 |
Hao Yin | Belle II | system | HardwareRun001 | | ADC Hot, FIRRun001, PedestalRun001
room temp pedrun
target: BW |
|
|
54
|
Mon Nov 30 17:13:47 2015 |
Hao Yin | Belle II | system | PedestalRun | | ADC Hot, FIRRun001
room temp pedrun |
|
|
53
|
Mon Nov 30 17:11:17 2015 |
Hao Yin | Belle II | module | FIRRun001 | FIRRun001 aft ADC_HOT | FirRun 20 min after I2C |
|
|
52
|
Mon Nov 30 15:18:12 2015 |
Hao Yin | Belle II | module | ADC_DELAY_HOT | ADC delay hot | ADC delay scan at room temp and 20 min
after APV I2C config.
measured values at display in the |
|
|
51
|
Mon Nov 30 15:12:19 2015 |
Hao Yin | | | | FIR_ADC config | FIR filter and ADC delay test:
ADC delay and FIR filter with and
without cooling to reproduce error detected |
|
|
50
|
Fri May 29 11:47:56 2015 |
Hao Yin | Belle II | system | PS Filter | Testing PS LV filter and quantifying the required min noise lvl | Data of this entry is recorded in the folder:
LV315kHz_Injections
Injecting noise to LV with a freq. |
|
|
49
|
Wed May 27 09:30:54 2015 |
Hao Yin | Belle II | system | CAEN PS Primary side | | Measured Primary side of caen wo load (setup
attachment 2 and prelimilary res. attachment
1. ) |
|
|
48
|
Mon May 25 20:27:23 2015 |
Hao Yin | Belle II | system | Caen PS base line measurements | | Baseline noise measurements wo injection.
measure noise in both HV and LV.
wings of APV25 using cmc with 128 |
|
|
47
|
Mon May 25 10:38:03 2015 |
Hao Yin | Belle II | system | L5 Ladder Emission Test | Emission | (TestNr: 16)
base line noise measurement are
saved in SYSTEM_CHECK_AFTER_WE. |
|
|
46
|
Fri May 22 12:01:32 2015 |
Hao Yin | | | | CMC injection LV 10V | Comparison w/o filter (LC) connected to
-z_n side.
Mateo has the results. |
|
|
45
|
Thu May 21 18:23:22 2015 |
Hao Yin | | | | Noise Injection LV cable | (TestNr. 15)
injecting sin wave into LV at different |
|
|
44
|
Wed May 20 10:12:12 2015 |
Hao Yin | | | | Ladder RLC test (CMC Injection) | L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder |
|
|
43
|
Tue May 19 14:48:06 2015 |
Hao Yin | Belle II | module | L6 Noise inJection Runs | L6 Noise inJection Runs | Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V. |
|
|
42
|
Tue May 19 13:42:04 2015 |
Hao Yin | | | | L6 Noise inJection Setup | Test Nr. 1:
RLC between DockBox and Hybrid
(both side). |
|
|
41
|
Tue May 19 13:23:16 2015 |
Hao Yin | Belle II | system | Calibration | CalibrationRun001 | PedestalRun001, FIRRun001,
room temperature,
no noise injection |
|
|
40
|
Tue May 19 11:01:29 2015 |
Hao Yin | Belle II | system | Pedestal | PedestalRun | FIRRun001
Baseline measurement without injections,
50000 event, |
16x |
|
39
|
Tue May 19 10:57:19 2015 |
Hao Yin | Belle II | system | FIR | FIR filter | first fir filter run:
# 1:[0x[FADC ID] in hex], 2:[APV25
ChannelNr], 3-10:[fir coef in float] |
|
|
38
|
Tue May 19 10:08:53 2015 |
Hao Yin | | | | FADC system setup success | 3 FADC. All Channel/APV25 running (except
L3 n first and last -> not connected (bonding))
n-side: all connectors |
|
|
37
|
Tue May 19 09:31:50 2015 |
Hao Yin | | | | Noise Test ITA | Everything works except L3 p-side.
The config file is shown in the
following: |
|
|
36
|
Thu Jun 5 10:34:45 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 10° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
35
|
Thu Jun 5 10:34:29 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 7° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
34
|
Thu Jun 5 10:34:06 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 4° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
33
|
Thu Jun 5 10:33:46 2014 |
Benedikt Würkner | Belle II | source | Silc Module | Silc Angle Measurement 1° | Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles. |
|
|
32
|
Fri May 16 11:40:29 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 6 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right) |
10x |
|
31
|
Fri May 16 11:38:44 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 5 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center) |
10x |
|
30
|
Fri May 16 11:37:05 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 4 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left) |
10x |
|
29
|
Fri May 9 16:44:41 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 3 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: -54:0(top center) |
10x |
|
28
|
Fri May 9 15:12:44 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: -27:0(top center) |
10x |
|
27
|
Thu May 8 16:51:57 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (single) | Failed with Error: "***ERROR*** Init
NECO failed, Return code: -32761"
Restarted and it works again |
|
|
26
|
Thu May 8 16:51:03 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: 0:0(top left) |
10x |
|
23
|
Wed May 7 18:20:36 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 6 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right) |
10x |
|
22
|
Wed May 7 17:33:21 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 5 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center) |
10x |
|
21
|
Wed May 7 16:43:37 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 4 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left) |
10x |
|
20
|
Wed May 7 15:53:38 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 3 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right) |
10x |
|
19
|
Wed May 7 15:04:32 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center) |
10x |
|
18
|
Wed May 7 14:36:29 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left) |
10x |
|
17
|
Sun Jul 4 05:48:36 2010 |
Christian Irmler | BELLE Upgrade | source | Origami 6 - module 1 | run002: first analysis results | Run name: run002
Run type: 0 (Hardware (Normal Run)) |
7x |
|
16
|
Wed Oct 7 14:24:06 2009 |
Dieter Uhl | BELLE Upgrade | hybrid | #5 | hybrid-pitchadapter | shorts at upper coat
|
|
|
15
|
Wed Oct 7 14:23:35 2009 |
Dieter Uhl | BELLE Upgrade | hybrid | #4 | hybrid-pitchadapter | opens at upper coat
|
|
|
14
|
Tue May 20 14:27:50 2008 |
Markus Friedl | BELLE Upgrade | source | micron | analysis results of source test |
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED
THAT BIASING WAS NOT DONE PROPERLY
|
9x |
|
13
|
Fri May 9 10:04:26 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 05/05 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.0 nA
Ibias (200 V) = 23.6 nA |
12x |
|
12
|
Fri May 9 10:00:34 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 03/10 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.9 nA
Ibias (200 V) = 25.5 nA |
12x |
|
11
|
Fri May 9 09:56:15 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 06/03 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 26.5 nA
Ibias (200 V) = 37.8 nA |
12x |
|
10
|
Wed May 7 19:05:08 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 04/04 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 27.8 nA
Ibias (200 V) = 32.7 nA |
12x |
|
7
|
Wed May 7 16:12:58 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 12/08 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 22.2 nA
Ibias (200 V) = 26.5 nA |
12x |
|
8
|
Wed May 7 15:40:07 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 07/07 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 20.2 nA
Ibias (200 V) = 21.9 nA |
12x |
|
9
|
Wed May 7 15:26:24 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 20/09 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 25.1 nA
Ibias (200 V) = 31.4 nA |
12x |
|
6
|
Wed May 7 15:24:49 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 10/02 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100V) = 19.1 nA
Ibias (200V) = 23.7 nA |
12x |
|
5
|
Wed Apr 30 16:52:17 2008 |
Markus Friedl | BELLE Upgrade | module | micron | micron sensor glued to frame | soeben haben wir den micron-DSSD (double metal
layer) in den 2-teiligen rahmen geklebt und
auf beiden seiten
|
|
|
4
|
Wed Apr 23 13:37:18 2008 |
Markus Friedl | SPS Testbeam June08 | source | hybrid 01 | analysis results of source test | Ignore the "KEK November 2007" title - that's
a legacy and is already changed :-)
|
|
|
3
|
Wed Apr 23 13:05:05 2008 |
Christian Irmler | SPS Testbeam June08 | source | hybrid 01 | time correlation between TDC and sensor measurement -> 3.1 ns RMS | |
|
|
2
|
Tue Apr 22 19:34:09 2008 |
Markus Friedl | SPS Testbeam June08 | module | hybrid 01 | Properties of hybrid 01, sensor fully bonded, HV=100V | HV bias glued to backplane, HV=100V |
6x |
|
1
|
Fri Apr 18 17:23:26 2008 |
Markus Friedl | SPS Testbeam June08 | hybrid | hybrid 01 | Noise of hybrid 01, sensor fully bonded, no HV | HV bias not yet glued to backplane |
|