Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Belle/Infineon/AIDA testbeam at SPS in Nov 2014, all entries  Not logged in ELOG logo
Entry  Sun Nov 23 18:26:54 2014, Markus Friedl, Belle SVD, HardwareRun, 005, 60600, 23.11.2014 18:24:34, 23.11.2014 , Good 

Hardware run, hitting APVs 2/3 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry is currently edited by Thomas Bergauer on 193.170.243.91  Entry  Sun Nov 23 17:51:44 2014, Benedikt Würkner, Belle SVD, HardwareRun, 046, 100000, 20:06, 20:36, Unknown 

Hardware Run +-60V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

 

Entry  Sun Nov 23 16:55:37 2014, Markus Friedl, Belle SVD, HardwareRun, 004, 60600, 23.11.2014 16:51:49, 23.11.2014 18:23:54, Good 

Hardware run, hitting APVs 1/2 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry  Sun Nov 23 15:13:37 2014, Markus Friedl, Belle SVD, HardwareRun, 003, 100600, 23.11.2014 14:07:23, 23.11.2014 16:51:27, Good 

Hardware run, hitting APVs 0/1 on p-sides, 1/2 on n-sides

EUDAT telescope running with difference of 2 events

Entry  Sun Nov 23 15:10:42 2014, Markus Friedl, Belle SVD, CalibrationRun, 001, 83400, , , Good 

Initial calibration run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side)

Entry  Sun Nov 23 15:09:53 2014, Markus Friedl, Belle SVD, PedestalRun, 001, 10000, , , Good 

Initial pedestal run with SVD3 setup and WedgeOld, FW993, BW993 (reading out 4 chips on every p-side)

Entry  Sun Nov 23 15:07:54 2014, Markus Friedl, Belle SVD, common, , , , , Unknown fwbw_setup.png

Geometry setup of FW/BW:

(all dimensions are in mm and refer to the sensor planes)

Entry  Sun Nov 23 12:55:47 2014, Benedikt Würkner, Belle SVD, HardwareRun, 045, 20000, , , Unknown 

Hardware Run +-50V Bias

Room Temperature

Pedestal 018 (again marked all the bad strips)

Zero Suppressed

Entry  Sun Nov 23 12:39:45 2014, Axel König, common, PMT's of EUDET (Igor Rubinsky), , , , , Unknown 

Der zweite PM (entsprechend der Beamrichtung) war von Anfang an nicht angeschlossen an die TLU! Stattdessen war ein Atlas pixel sensor, welcher als 4ter PM fungiert angeschlossen. Genau dieser "PM" hatte 0 counts bei der TLU --> Igor sagt, dass dieser Sensor ("PM") anscheinend keine Versorgungsspannung hatte (~400V). Jetzt baut Igor diesen Atlas Sensor wieder aus und hat bereits den nicht angeschlossenen PM wieder angeschlossen an die TLU. DIeser PM zeigt aber nun zu viele counts. Deshalb behalten wir die AND mask 11 (auch jetzt bei den Belle Modulen).

Entry  Sun Nov 23 12:17:59 2014, Benedikt Würkner, Belle SVD, HardwareRun, 044, 20000, , , Unknown 

Hardware Run +-30V Bias

Room Temperature

Pedestal 017 (again marked all the bad strips)

Zero Suppressed

Entry  Sun Nov 23 10:51:49 2014, Hao Yin, Belle SVD, HardwareRun, 042, 76863, , , Unknown Temp_23-11-14.PNG

Hardware Run +-40V Bias

Room Temperature

Pedestal 016

Zero Suppressed

Entry  Sun Nov 23 10:32:41 2014, Hao Yin, Belle SVD, PedestalRun, 016, 10000, , , Unknown 

Pedestal Run

room temperature (30C)

Bias scans planned

Entry  Sun Nov 23 09:49:00 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown temp_last_night.png

Saturday evening, the cooling became unstable which indicates the end of the CO2 supply, possibly having a mixture of liquid and gas phases.

Strange oscillations observed for the DUT temperatures until the MF valve was finally turned off close to midnight.

 

Entry  Sun Nov 23 09:36:27 2014, Axel König, Infineon, hardware run, Infineon_old_run006, 526562, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:95

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000998

DaqEvents: 526562 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

Entry  Sun Nov 23 09:32:48 2014, Axel König, Infineon, hardware run, Infineon_old_run007, 63913, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4028uA

(new table calibration): V:75, H:96.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000999

DaqEvents: 63913 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset)  

Entry  Sun Nov 23 01:37:42 2014, Hao Yin, Belle SVD, HardwareRun, 040, 20000, 2014-11-23 01:37:00, , Unknown 

Bias voltage set to +-80V

Pedestal_015 (cooled)

"New" layout with no cooling (CO2 is no more)

Newly set values for APC Delay

New FIR Run 005

Temperature around 30 C

Bias: +-80V

Entry  Sun Nov 23 01:05:43 2014, Hao Yin, Belle SVD, HardwareRun, 039, 20000, 2014-11-22 15:18:40, , Crap 

Cooled down to -20

Bias voltage set to +-80V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

 

Entry  Sun Nov 23 00:51:07 2014, Axel König, Infineon, hardware run, Infineon_old_run005, 26569, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.4609uA

(new table calibration): V:75, H:94.5

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000997

DaqEvents: 26569 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

 
Entry  Sun Nov 23 00:24:15 2014, Axel König, Infineon, hardware run, Infineon_old_run004, 168725, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.6529uA

(new table calibration): V:81, H:88

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000996

DaqEvents: 168725 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sun Nov 23 00:20:41 2014, Axel König, Infineon, hardware run, Infineon_old_run003, 30000, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:?, H:?

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000994

DaqEvents: 30000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 19:29:40 2014, Axel König, AIDA, DUT Position, , , , , Unknown AIDA_DUT_Position.JPG
 
Entry  Sat Nov 22 18:08:03 2014, Axel König, Infineon, hardware run, Infineon_old_run002, 55000, , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:102mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000993

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 17:00:43 2014, Axel König, Infineon, Infineon old, damaged strixel sensors, strange IV behaviour, , , , Unknown 

1.) No events recorded for strixel sensors (run001). They seem to be damaged like they were at DESY.

2.) Very strange IV behaviour for every old Infineon module (especially TB12_baby1). 

Entry  Sat Nov 22 16:53:39 2014, Axel König, Infineon, Infineon old, Infineon_old_run001, 55000 , , , Unknown 

Infineon old

multi hit

Voltage=300V, I=10.9797uA

(new table calibration): V:81mm, H:97mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000992

DaqEvents: 55000 (-600 ped)

EUDAQ EVENTS: daq events - 600 (+2 offset) 

Entry  Sat Nov 22 16:43:18 2014, Axel König, common, table, telescope and dut geometry , , , , , Unknown geometry_table.pdfgeometry_DUT.pdfgeometry_infineon_batch4.pdfgeometry_infineon_old.pdf

geometry files

Entry  Sat Nov 22 16:04:05 2014, Axel König, Infineon, Infineon old calibration, Infineon_old_calibration, , , , Unknown 

Calibration run 

L:\cern14\infineon_old

Entry  Sat Nov 22 15:31:49 2014, Hao Yin, Belle SVD, HardwareRun, 038, 43788, 2014-11-22 15:18:40, , Unknown 

Cooled down to -20

Bias voltage set to +-60V

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Zero suppressed

Entry  Sat Nov 22 11:37:16 2014, Benedikt Würkner, Belle SVD, HardwareRun, 036, 450378, 2014-11-22 1:00:00, 2014-11-22 10:27:54, Unknown SPS_Testbeam-Temp.xlsxScreen_Shot_2014-11-22_at_12.41.44.png

 Not completely cooled since cooling failed at 1:42 in the night

Bias voltage set to +-60V

Some error with event no17 or 18 leading to the data not being easily analysable requiring a hack in TuxOA

Pedestal_013 (cooled)

Noisefile: HardwareRun_036.noi

Entry  Sat Nov 22 11:16:26 2014, Markus Friedl, Belle SVD, cooling, , , , , Unknown 

Cooling box plant hung up (I2C error on Alix, persistent after reboot)

Power-cycled cooling plant, now working

Slowly cooling down again

Entry  Sat Nov 22 10:20:07 2014, Axel König, AIDA, calibration run, AIDA_calibration, , , , Unknown 

Calibration run AIDA_calibration 

L:\cern14\AIDA

Entry  Sat Nov 22 07:56:33 2014, Axel König, AIDA, hardware run, AIDA_run013, 55629, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:45mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000990

DaqEvents: 55629 (-600 ped)

EUDAQ EVENTS: 55003 

 
Entry  Sat Nov 22 00:58:04 2014, Axel König, AIDA, hardware run, AIDA_run012, 276006, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3417uA

(new table calibration): V:51mm, H:70mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000989

DaqEvents: 276006 (-600 ped)

EUDAQ EVENTS: 275390 

Entry  Sat Nov 22 00:11:36 2014, Axel König, AIDA, hardware run, AIDA_run011, 24916, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000988

DaqEvents: 24916 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

Entry  Fri Nov 21 23:40:10 2014, Axel König, AIDA, hardware run, AIDA_run010, 26329, , , Unknown 

  

AIDA

multi hit

Voltage=100V, I=5.3470uA

(new table calibration): V:71mm, H:90mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: run000987

DaqEvents: 26329 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Fri Nov 21 23:34:36 2014, Axel König, AIDA, hardware run, AIDA_run009, 32902, , , Unknown 

 

AIDA

multi hit

Voltage=100V, I=5.2190uA

(new table calibration): V:71mm, H:100mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 32902 (-600 ped)

EUDAQ EVENTS: DAQ events -600 (+1 trigger offset)

 
Entry  Fri Nov 21 23:33:54 2014, Axel König, AIDA, hardware run (PC crashed), AIDA_run008, ---, , , Unknown 

22:00 SVD3 PC crashed!!! data will be collected. 

Entry  Fri Nov 21 22:08:32 2014, Hao Yin, , PedestalRun, 013, 10000, , , Unknown 

correct mapping

cooled -25 °C

L3n deactivated

 

Entry  Fri Nov 21 19:42:36 2014, Hao Yin, , HardwareRun_033, , , , , Good Temp_21-11-14.PNG

L6 are swapped, needs to be corrected later in the offline analysis.

cooled at -25

latest ADC delay and FIRRun

PedestalRun_012

CalibrationRun_006

100k trigger dead time

 

Need to change L6n apv definition to:

mod = 9,0,1,1,1,m,29,0,0,0,0,0,0,L6_n_side

apv = 9,1,34,3,30,x,0,0,5,1,7,0,0,x
apv = 9,0,36,3,50,x,0,0,5,1,6,0,0,x
apv = 9,3,38,3,30,x,0,0,5,1,9,0,0,x
apv = 9,2,40,3,30,x,0,0,5,1,8,0,0,x

to  get the right mapping of the sensor.

Entry  Fri Nov 21 19:25:57 2014, Axel König, AIDA, hardware run, AIDA_run007, 26770, , , Unknown 

AIDA

multi hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:65mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000983

--Stopped 21.11 / 19:20--

DaqEvents: 26770 (-600 ped)

EUDAQ EVENTS: 26171 (+1 trigger offset)

Entry  Fri Nov 21 19:10:09 2014, Hao Yin, Belle SVD, CalibrationRun_006, , , , , Unknown 

cooled, latest ADC delay scan and FIRRun. 

Entry  Fri Nov 21 19:05:27 2014, Hao Yin, Belle SVD, FIRRun_004, , , Fri Nov 21 19:05:23 CET 2014, , Unknown 

New ADC delay scan. cooled, -25 temperature

 

Entry  Fri Nov 21 18:35:17 2014, Axel König, AIDA, Important: Dockbox Inverter!, , , , , Unknown 

Alle AIDA runs vor run_007 hatten kein Signal auf den Sensoren 5 und 6.

Grund: Inverter auf N Seite war im config file noch an (von Markus behoben). 

Runs vor 007 können noch verwendet werden obwohl sensoren 5 und 6 negative Events lieferten (kommt aber auf das negative Limit an). 

Entry  Fri Nov 21 18:23:05 2014, Axel König, common, New Table Calibration, , , , , Unknown 

 Nach powercut musste der Tisch neu kalibriert werden. Diese Neukalibration betrifft alle Messungen ab den ersten Messungen vom AIDA Stack.

Entry  Fri Nov 21 18:21:45 2014, Axel König, AIDA, hardware run, AIDA_run006, ~1k, , , Unknown 

 verwerfen!

Entry  Fri Nov 21 18:20:47 2014, Axel König, AIDA, hardware run, AIDA_run005, 20045, , , Unknown 

AIDA

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000979

--Stopped 21.11 / 12:12--

DaqEvents: 20045 (-600 ped)

EUDAQ EVENTS: ~18k

Entry  Fri Nov 21 15:37:30 2014, Axel König, AIDA, hardware run, AIDA_run004, 7057, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4357uA

(new table calibration): V:71mm, H:80mm

 

config: L:\cern14\AIDA

data: L:\cern14\AIDA

EUDAQ File: Run000977

--Stopped 21.11 / 12:12--

DaqEvents: 7057 (-600 ped)

EUDAQ EVENTS: 4658 (less than Daq) 

Entry  Fri Nov 21 15:10:19 2014, Benedikt Würkner, , HardwareRun, 15-22 (exept 19) , none, , , Crap 
 
Entry  Fri Nov 21 15:07:24 2014, Benedikt Würkner, Belle SVD, HardwareRun, 019, 150948, 2014-11-21 02:41:55, 2014-11-21 10:11:02, Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)

VME Error, overnight run

Entry  Fri Nov 21 15:03:08 2014, Benedikt Würkner, Belle SVD, HardwareRun, 014, 989, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 15:02:28 2014, Benedikt Würkner, Belle SVD, HardwareRun, 013, 1433, , , Unknown 

cooled see appendix (FirRun003)
PedestalRun_010
multi 6 Raw Mode
FIFO size increased
L3n deactivated
100000 deadtime (CTRL TRG)
Zero_suppressed

Entry  Fri Nov 21 12:14:46 2014, Axel König, AIDA, hardware run, AIDA_run003, 20617, , , Unknown 

AIDA

 

single hit

Voltage=100V, I=5.4240uA

(new table calibration): V:66mm, H:74mm

EUDAQ file:  Run000965

config: L:\cern14\AIDA

data: L:\cern14\AIDA

 

--Stopped 21.11 / 12:12--

DaqEvents: 20617 (-600 ped)

EUDAQ EVENTS: 20019 (2 more than DAQ [+2 offset]) 

Entry  Fri Nov 21 11:10:08 2014, Axel König, AIDA, hardware run, AIDA_run002, 211362, , , Unknown 

AIDA

multi hit
Voltage=100V, I=4.1688uA
(new table calibration): V:56mm, H:96mm
 
EUDAQ File: Run000962, Run000963, Run000964
 
config: L:\cern14\AIDA
data: L:\cern14\AIDA
 
--Stopped 21.11 / 10:30--
DaqEvents: 211362
EUDAQ EVENTS: ca. 41000
Entry  Fri Nov 21 01:43:54 2014, Axel König, AIDA, calibration run, AIDA_run001_calibration, , , , Unknown 

Calibration run with AIDA DUT.

Single hit

Entry  Thu Nov 20 22:12:21 2014, Axel König, common, SPS Logbook / SPS Online Monitor, , , , , Unknown 

Logbook: https://ab-dep-op-elogbook.web.cern.ch/ab-dep-op-elogbook/elogbook/secure/eLogbook.php?shiftId=1059325

 

Monitor:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

Entry  Thu Nov 20 22:11:06 2014, Hao Yin, Belle SVD, HardwareRun, 012, , , , Good 

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

Entry  Thu Nov 20 18:15:48 2014, Axel König, Infineon, hardware run, Infineon_run013_voltage, 51273, , , Unknown 

Infineon new stack - batch 4 

single hit + eudaq
 
HV=100V, total I = 3.0326 µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
eudaq file: run000959.raw
 
--stopped 20.11 // 18:10 --
Eudaq: 54928
Events: 51273
Entry  Thu Nov 20 17:16:56 2014, Axel König, common, how to run the EUDAQ offline monitor, , , , , Unknown 

YOU need

1.) Folder EUDAQ OFFLINE Monitor

2.) ROOT

 

Starting: 

1.) open command line and chose the path where OfflineMonitor is

2.)Type -i "patch of raw file" -o test.root 100

3.) helpfile typing -h

Entry  Thu Nov 20 16:13:18 2014, Hao Yin, Belle SVD, HardwareRun, 011, , , , Crap 

cooled see appendix (FirRun003)

PedestalRun_009

multi 6 Raw Mode

FIFO size increased

 

 

FIFO FULL at  event ~27000

Entry  Thu Nov 20 15:47:56 2014, Axel König, Infineon, hardware run, Infineon_run011, , , , Unknown 

 Infineon new stack - batch 4 

 faulty!!!
Entry  Thu Nov 20 15:46:21 2014, Axel König, Infineon, hardware run, Infineon_run012, 263470, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = ? µA
 
strips vertical
 
Table Position: H: 89mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 20.11 // 15:30 --
Eudaq: No Events build --> searching for failure
Events: 263470
Entry  Thu Nov 20 15:32:33 2014, Hao Yin, , HardwareRun, 010, , , , Crap 

same as hardware run 009

FIFO FULL ERROR starting at ~event 5000

Entry  Thu Nov 20 11:14:19 2014, Benedikt Würkner, , HardwareRun_009, 009, , , , Crap 

 cooling see attachment of FIRRun003

Ped 009

Cal 005

Multi 6 raw mode

L5_n_side out of order

 

FIFO_FULL_ERROR starting at ~2000 events

Entry  Thu Nov 20 11:13:44 2014, Hao Yin, , HardwareRun_008, 008, , , , Crap 

cooled see attachment in FIRRun_003

PedestalRun_009

CalibrationRun_005

zerosuppressed

Entry  Thu Nov 20 10:41:54 2014, Benedikt Würkner, Belle SVD, CalibrationRun_005, , , , , Unknown 

 cooled see appendix (FIRRun_003)

PedestalRun_009

Entry  Thu Nov 20 10:39:13 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:39:11 2014, Benedikt Würkner, Belle SVD, PedestalRun_009, , , , , Unknown 

cooled see appendix (FIRRun003)

MaxEvents 10000

 

Entry  Thu Nov 20 10:33:13 2014, Benedikt Würkner, Belle SVD, FIRRun and Delay Scan, 003, , , , Unknown Temp_19-11-14.PNG

 Cooled see appendix

with new layout (l3_n-side channels changed and reactivated).

Latest FIRRun

Entry  Thu Nov 20 10:22:17 2014, Markus Friedl, Belle SVD, common, , , , , Unknown 
  1. Some VME errors occured over night
  2. Optical fiber changed
  3. Situation improved

 

  1. L3n hybrid could not be configured by I2C
  2. Plugged cable into the former FWDn slot
  3. Fully working

 

Entry  Thu Nov 20 00:55:14 2014, Hao Yin, Belle SVD, HardwareRun_007, , , , , Unknown 

temp cooled see attachment

last noise run(007)

FIRRun_002

PedestalRun_008

new cal run Raw, test with put fifo full flags

Entry  Thu Nov 20 00:54:21 2014, Hao Yin, Belle SVD, PedestalRun_008, , , , , Unknown 

temp see attachment (von flo)
10000
latest fir filter (002)

Entry  Thu Nov 20 00:52:50 2014, Hao Yin, Belle SVD, FIRRun_002, , , , , Unknown 

cooled with new delay run

Entry  Wed Nov 19 23:31:08 2014, Hao Yin, Belle SVD, HardwareRun_004, , , , , Unknown 

Same as HardwareRun_003 but with ZS.  

Entry  Wed Nov 19 23:15:50 2014, Hao Yin, Belle SVD, HardwareRun_003, , , , , Unknown 

cooled, latest noise, cal, PedestalRun.

Rawmode

Entry  Wed Nov 19 22:59:24 2014, Hao Yin, Belle SVD, CalibrationRun_004, , , , , Crap 

cooled (see last calibration run)

Latest noise, FIRfilter settings. 

 

Failed due to VME read timeout.

Entry  Wed Nov 19 22:25:29 2014, Hao Yin, Belle SVD, PedestalRun_008 [CheckLayout], , , , , Unknown 

cooled (temperature see attachment latest noise run),

latest Noise, FIR settings with the right layout mapping.

Entry  Wed Nov 19 22:15:41 2014, Axel König, Infineon, hardware run, Infineon_run010, 1498709, , , Unknown 

Infineon new stack - batch 4 

 
single hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
EUDAQ data: Run951 and Run952
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped 20.11 / 09:35-- 
 
SVD3DAQ Events: 1498709
EUDAQ Events: 2777
 
EUDAQ stopped counting events --> log entry: "01:38 6-ERROR unexpected trigger number 277714 (expecting 277713)" (TLU Producer)
Entry  Wed Nov 19 21:56:44 2014, Axel König, Infineon, hardware run, Infineon_run008, 244167, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0758 µA
 
strips vertical
 
Table Position: H: 92.5mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 19.11 // 21:53 --
Reason: Want to run the eudaq for the next run
Events: 244167
Entry  Wed Nov 19 20:07:05 2014, Hao Yin, Belle SVD, HardwareRun_002, , , , , Unknown 

Multi-6 cooled.

See latest Noise, and PedestalRun.

 

Entry  Wed Nov 19 20:04:53 2014, Hao Yin, Belle SVD, PedestalRun_006, , , , , Unknown Temp_19-11-14.PNG

Temperature: See attachment

FIRFilterRun_002

Layer 3-n side deactivated, because Hao broke it.

Entry  Wed Nov 19 18:20:29 2014, Axel König, Infineon, calibration run, Infineon_run007_cal, , , , Unknown 
 
Entry  Wed Nov 19 16:24:25 2014, Axel König, common, Running EUDAQ, , , , , Unknown 

Windows PC at Telescope:

0.) JTAG Programming: Chose a threshold file (recommended threshold 5) File: M26TB_Cern_2011.thresh5.mcf--> press start

1.) C:\Users\telescope\Desktop\users\BelleII --> start Mimosa 26 Telescope --> select all six Mimosa's

2.) C:\Users\telescope\Desktop\users\BelleII --> start startEudaq_fullWindows.bat

3.) Use configuration file hephy1 (location: C:\eudaq\conf). Change it according to your TLU settings (DUT mask, AND mask, etc.)

4.) configure

5.) start

x) Online monitor in preparation

Files: Are saved in C:\eudaq\data with internal numbering "run000000xxx.raw" (look at the date and time). [You can connect locally to this folder at HEPHY-SVD PC]

Entry  Wed Nov 19 09:26:39 2014, Axel König, Infineon, hardware run, Infineon_run006, 1500, , , Unknown 

Infineon new stack - batch 4

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 91mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
-- stopped --
1500 Events only --> no trigger signals from TU (01:30 Uhr)
Entry  Wed Nov 19 00:58:27 2014, Axel König, Infineon, hardware run, Infineon_run005, 87000, , , Unknown 

Infineon new stack - batch 4 

multi hit
 
HV=300V, total I = 4.0200 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_multi6.cfg
 
--stopped 19.11 // 01:00 --
Reason: Enough events, new dut postion for next multi run
Events: 87000
Entry  Tue Nov 18 23:04:34 2014, Axel König, Infineon, hardware run, Infineon_run004, 400000, , , Unknown 

Infineon new stack - batch 4 

single hit
 
HV=300V, total I = 4.0044 µA
 
strips vertical
 
Table Position: H: 96mm V: 81mm
 
data file in L:\cern14\infineon\Infineon Run vert
 
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
--stopped 18.11 // 23:05---
Reason: Enough events, next run with the same position but now multi six
Events: 400000
 
Entry  Tue Nov 18 20:42:18 2014, Benedikt Würkner, Belle SVD, Coordinates of the DUT, , , , , Unknown 

We set the coordinates trying to put the beam in an area with well working APVs

Peak of course differs for n and p sensors due to their different pitch.

L4-6 n-side Peak around strip 180

L4&6 p-side mean value around strip 380

L5 p-side moved by 4.8mm due to reasons (APV misalignment I think) therefore the peak of the same measurements is moved by 4.8/75µm = 64 strips therefore centered around strip 320

The coordinates of the x-y table were set to 0:0 at this point. Refer to Run Alignment2 for reference data.

Entry  Tue Nov 18 20:26:12 2014, Hao Yin, Belle SVD, HardwareRun_001, , , Tue Nov 18 18:21:50 CET 2014, , Unknown 

At room temperature

Latest ADC scan and FIR run.

Latest CAL.

 

Position: 0.0, see elog entry.

Entry  Tue Nov 18 18:45:01 2014, Hao Yin, Belle SVD, Trigger Delay scan, , , Tue Nov 18 18:21:50 CET 2014, , Unknown 

At room temperature

First run was at: 23 (no track)

 

TimingRun_001:

Trigger delay: 26

 

TimingRun_002:

Trigger delay: 29

 

TimingRun_003:

Trigger delay: 32


 

TimingRun_004:

Trigger delay: 20

 
 

TimingRun_005:

Trigger delay: 17

 

TimingRun_005:

Trigger delay: 14
Trigger chip delay: 110

 

 

 

Entry  Tue Nov 18 18:33:31 2014, Axel König, Infineon, hardware run, Infineon_run003, 300000, , , Unknown 

Infineon new stack - batch 4

single hit

HV=300V, total I = 4.0044 µA

strips vertical

Table Position: H: 96mm V: 101mm

data file in L:\cern14\infineon\Infineon Run vert

config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg

 

--Stopped 18.11 / 20:20---

Reason: Enough events, adjusting new DUT position for next run

Events: 300000

Entry  Tue Nov 18 18:29:55 2014, Axel König, Infineon, calibration run, Infineon_run002, , , , Unknown 

Infineon_run002 is just a calibration run for the vertical positioned sensors. 

data file in L:\cern14\infineon\Infineon Run vert
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
Entry  Tue Nov 18 13:13:53 2014, Thomas Bergauer, Infineon, hardware run, infineon_run001, 225508, , , Unknown 

Infineon new stack - batch 4

single hit
 
HV=300V, total I = 4.2475 µA
 
strips horizontal
 
data file in L:\cern14\infineon\Infineon Run horiz
config file l:\cern14\infineon\Infineon Run horiz\cern14_infineon_single.cfg
 
 
STOPPED by main User in H6B (18:11, 15:00)
 
Events: 225508
Next step: rearange modules vertically
 
Entry  Tue Nov 18 12:35:32 2014, Axel König, common, Infineon (4 modules) TLU Settings, , , , , Unknown 
  1.  VNC to 192.168.0.18
  2. In command line: cd C:\Users\telescope\eudaq\bin
  3. TLUControl.exe.exe -d 2 -a 11 - i RJ45

Operating with AIDA telescope: TLUControl.exe.exe -d 3 -a 11 - i RJ45

Dut Position (left to right):  11, 06, 05, 07

Entry  Tue Nov 18 10:26:56 2014, Hao Yin, Belle SVD, CalibrationRun_003, , , Tue Nov 18 10:26:52 CET 2014, , Unknown 

At room temperature

Latest delay and FIRRun 

Entry  Tue Nov 18 10:12:25 2014, Hao Yin, Belle SVD, 6let PedestalRun_005, , 10000, Tue Nov 18 10:11:45 CET 2014, , Unknown 

At room temperature

Latest delay, FIRRun002. 

Check for bad strips.

Entry  Tue Nov 18 09:51:11 2014, Hao Yin, , CalibrationRun_002, , , Tue Nov 18 09:50:24 CET 2014, , Unknown 

At room temperature

PedestalRun004 

Latest delay settings and FIRRun

Entry  Tue Nov 18 09:48:53 2014, Hao Yin, Belle SVD, PedestalRun_004, , 10000, Tue Nov 18 09:48:30 CET 2014, , Unknown 

At room temperature.

Old delay settings and FIRRun_002

 

Entry  Tue Nov 18 09:45:59 2014, Hao Yin, , FIRRun_002, 002, , Tue Nov 18 09:45:58 CET 2014, , Unknown 

New FIR run after reconecting to original setting. 

Entry  Tue Nov 18 01:05:04 2014, Hao Yin, Belle SVD, PedestalRun_003, , , Tue Nov 18 01:03:32 CET 2014, , Unknown 

New pedestal run after switching the connectors.

At room temperature 

Entry  Tue Nov 18 01:03:18 2014, Hao Yin, Belle SVD, Remapped FADC inputs, , , Tue Nov 18 01:03:32 CET 2014, , Unknown 

We moved the second cable to the third connector on the FADC to match DESY testbeam conditions. 

Entry  Mon Nov 17 23:04:57 2014, Hao Yin, Belle SVD, PedestalRun_002, , 10338, Mon Nov 17 23:03:03 CET 2014, , Unknown 

Pedestal run at room temperature.

6 subevents. Noise reference run.

Delay as latest run.

 

Reference run for bad strips.

Entry  Mon Nov 17 22:28:09 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Mon Nov 17 22:28:07 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Mon Nov 17 22:28:05 2014, Hao Yin, , CalibrationRun, 001, , Mon Nov 17 22:27:07 CET 2014, , Unknown 

Noise file from run 001 

PedestalRun_001

FIRRun_001

At room temperature

See DelayRun_001

 

Entry  Mon Nov 17 22:22:56 2014, Hao Yin, , PedestalRun_001, 001, 10000, Mon Nov 17 22:22:41 CET 2014, , Unknown 

At room temperature.

 

Entry  Mon Nov 17 22:21:50 2014, Hao Yin, , Bad APVs, , , Mon Nov 17 22:08:29 CET 2014, , Unknown 

List with bad APVs:


 

Crap:

 APV 5 L6-p Channel 23

 

Not working:

 L3-n APV 3

 

Entry  Mon Nov 17 22:21:41 2014, Hao Yin, , FIR run, 001, , Mon Nov 17 22:08:29 CET 2014, , Good 

Excellent, brilliant run. 

Entry  Mon Nov 17 22:18:27 2014, Hao Yin, Belle SVD, ADC delay scan, , , Mon Nov 17 22:08:29, , Unknown 

L3-p: 18

L4-p: 36

L5-p: 33

L6-p: 39

 

L3-n: 18

L4-n: 36

L5-n: 36

L6-n: 35

Entry  Mon Nov 17 22:03:02 2014, Martin Kurz, common, Drucker, , , , , Unknown 

Drucken über den Printserver (192.168.0.150):

 

MAC:

direkt über den universellen AirPrint Treiber oder mittels Treiber vom Gerätehersteller drucken.

Einfach nach Druckern suchen. Druckername: CanonMP630 @ higgscms


LINUX:

Eine Datei Names (/etc/cups/client.conf) mit dem Inhalt folgenden Inhalt -ohne Anführungszeichen- erstellen: "ServerName 192.168.0.150"

--> sofort steht der Drucker mit allen richtigen Einstellungen zur Verfügung

Drucken mittels Treiber vom Gerätehersteller ist weiterhin möglich. (wird von CUPS automatisch zur Verfügung gestellt) CUPS URL: "http://192.168.0.150:631/printers/CanonMP630"

 

WINDOWS:

1.) Unter Start->Einstellungen->Drucker und Faxgeräte links den Punkt “neuen Drucker hinzufügen” auswählen.

2.) In dem sich öffnenden Assistenten die Option “Netzwerkdrucker hinzufügen” auswählen und auf “weiter” klicken.

3.) Zunächst den Punkt “Verbindung mit einem Drucker im Internet herstellen” auswählen und dann die "URL" zum Drucker einfügen.

Name: http://192.168.0.150:631/printers/CanonMP630

 

 

Entry  Mon Nov 17 19:23:57 2014, Thomas Bergauer, Infineon, PI XY table initial position, , , , , Unknown 

initial position of Infineon Stack (PI Micromove):
(guess center position by eye)

STRIPS IN HORIZONTAL DIRECTION

* vertical axis: M511.DD: Zero position 81.0mm / higher values correspond to lowering the table

* vertical axis: M521.DD: Zero position 96.0mm / higher values correspond to move the table to the table mounting

Entry  Sun Nov 16 21:37:56 2014, Hao Yin, common, AIM, , , , , Unknown 

fachi:  aimhephy@antispam.e4ward.com

chrisu:  gargamel0971

flo: flo.bux@sbg.at

shorty: martin@kurznet.net

markus; mueffi1040

hao: hao.yin@gmx.at

benni: benedikt.wuerkner@assoc.oeaw.ac.at

juan: juan.garcia.ferrero@cern.ch

axel: ???

bergi: callmebergi

Entry  Sun Nov 16 14:22:51 2014, Thomas Bergauer, AIDA, PC Configuration EUDET Telescope in H6b, , , , , Unknown 

PC (gehört AIDA) in H6b control room:  ssh telescope@pcaidatb.cern.ch

 

 

Entry  Sat Nov 15 12:41:50 2014, Benedikt Würkner, Belle SVD, Discoveries during preliminary sensor tests, , , , , Unknown weird_signal.pngfaulty-signal-l4_n.pngfaulty-signal_l4_n_2.png

L5_p_side APV #3 faulty signal

L4_n_side APV #2 and #3 faulty signal

Entry  Sat Nov 15 11:37:19 2014, Thomas Bergauer, AIDA, List of EUDET Telescope PCs in H6b, , , , , Unknown 

 https://twiki.cern.ch/twiki/bin/view/CLIC/ClicPixelDataTakingCERNPS2014

Entry  Sat Nov 15 11:36:41 2014, Thomas Bergauer, common, Checklist for North Area access, , , , , Unknown 

 

Checklist for North Area access: 

  • Dosimeter (http://dosimetry.web.cern.ch/en)
  • Helmet and safety shoes (http://gs-dep.web.cern.ch/en/content/stores_hours)
  • Access right to H6A control room (request via EDH): Control Room HNA-447 (0887-1-Q45). Activate access right on your CERN access card at one of the validation stations (https://espace.cern.ch/service-access-control/default.aspx)
  • For using CERN rental car, request "CERN vehicle driving license (V)" via EDH
  • Park in front of bldg. 890. Walk to North Hall (bldg. 887) through bldg. 907. Swipe dosimeter in front of electronic lock next to the entrance door. Turn left inside bldg. 887. Control room Q45 is on the left-hand side of the upper level. Swipe CERN access card in front of electronic lock.
Entry  Fri Nov 14 19:52:12 2014, Thomas Bergauer, , important web pages, , , , , Unknown 

SPS Accelerator status:  http://op-webtools.web.cern.ch/op-webtools/vistar/vistars.php?usr=SPS1

general Information about the Beam line(s): http://sba.web.cern.ch/sba/

Entry  Fri Nov 14 19:49:04 2014, Florian Buchsteiner, common, Belle Setup, , , , , Unknown SPS_2014_Testbeam_-_Belle_Setup-Model.pdf
 
Entry  Fri Nov 14 19:47:25 2014, Thomas Bergauer, , Telefonnummern, , , , , Unknown 

* CCC (zentraler Beschleuniger-Kontrollraum): 77500

* H6A Controlroom: 76755

* HEPHY-Handy: 16-2471 or +41 76 487 2471 from outside of CERN

* Office in Meyrin: 12-R11: 74592

 

Hostel-Zimmern:

* Bergi: 79326

* Benni: 60232

* Hao: 70408

 

Andere Wichtige Leute:

* Beam-Dame: Edda Gschwendner 16-5080

* NA Hallen Verantwortlicher: Michael Jeckel

Lookup Telefonnummern: http://phonebook.cern.ch

 
Entry  Fri Nov 14 19:22:40 2014, Martin Kurz, common, ip addresses, portforwarding, wlan, , , , , Unknown 

WLAN Router:

SSID: Hephy

password: 20supersecret14

DHCP Range: 192.168.0.200 to 239

Netmask: /24

DNS Server: 192.168.0.254

Gateway: 192.168.0.254

external IP: 128.141.61.16 (für diverse Port Forwardings)

 

Manuell vergebene IP Adressen bitte unbedingt Martin Kurz mitteilen oder/und in der folgenden Tabelle eintragen! 

IP/MAC Zuweisung:

IP Machine/Name intern Port Forwarding (aussen)
192.168.0.10 SVD Kenwood  VNC(5900)  VNC(9000)
192.168.0.11 AIDA DAQ  VNC(5900)  VNC(9001)
192.168.0.12 TUX DAQ  VNC(5900), VNC(5901), SSH(22)  VNC(9009), VNC(9002), SSH(9003),
192.168.0.13 Belle XY Tisch    
192.168.0.14 TUXOA  SSH(22)  SSH(9004)
192.168.0.15 JTAG Server    
192.168.0.148 alixcool    
192.168.0.16 slowcontrol  VNC(5900)  VNC(9005)
192.168.0.144 CAEN Power supply    
192.168.0.17 zenpixelwiki  SSH(22), VNC(5900)  SSH(9006), VNC(9008)
192.168.0.18 TLU (pcx25042, XY)  VNC(5900)  VNC(9007)
192.168.0.240 NI GPIB - ENET / 1000    
192.168.0.150 Printserver  VNC(5900)  VNC(9010)
       
       

 

Admin Zugang Wlan Router:

IP: 192.168.0.254

Username: admin

password: Hephy2014

 

Entry  Fri Nov 14 19:01:27 2014, Thomas Bergauer, common, Administrative Procedures for Departure, , , , , Unknown Merchandise-2014.pdfankunftsbestaetigung.pdf

Wednesday:

* Transport request starten (I do not need any transport service) von 887 nach Wien. Das triggert automatisch die Radio Protection Leute. Der EDH Request hängt dann bei irgend einem Franzosen. Den bitte anrufen und für Montag mittags einen Termin ausmachen. Es muss alles geschnüffelt werden, was in der Zone war (also nicht im Counting room)

Merchandise-Bestätigung für die Anreise ist im attachment!

 

Anreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5855845

Abreise: https://edh.cern.ch/Document/SupplyChain/SHIP/5863835

ELOG V3.1.5-fc6679b