Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS October 2011, Page 4 of 5  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTime Datadown Text Attachments
  29   Tue Oct 4 15:16:45 2011 Manfred ValentanMicronMicron-Baby-Stack p-spray, run bottom right NOT USABLErun004200k4.10.2011 15:28:4804.10.2011 19:36:50CrapHAS TO BE REPEATED!!! Before this run there
were changes in the trigger line (vetoing
the trigger when no spill), and thus the
  
  31   Tue Oct 4 22:11:12 2011 Christian IrmlerBELLEOrigami stackrun00533000004.10.2011 22:09:3705.10.2011 09:11:54CrapOrigami6
HV=+-40V, no cooling
beam on
  
  32   Wed Oct 5 12:09:00 2011 Christian IrmlerBELLEOrigami stack cooled wrong I2C settingscal0058380005.10.2011 12:04:5005.10.2011 12:37:11CrapThis calibration file can not be
used, due to wrong I2C settings!
Origami6
  
  33   Wed Oct 5 13:00:41 2011 Christian IrmlerBELLEOrigami stack cooled run0062469205.10.2011 12:55:5305.10.2011 14:05:49CrapRun stopped after 24692 events,
because all n-side APV failed due to a shortcut
of a capacitor (C223) on n-side rebo
  
  37   Wed Oct 5 19:57:15 2011 Christian IrmlerBELLEOrigami stack cooled run0071784505.10.2011 18:27:5105.10.2011 19:31:43CrapRun stopped after 17845 events,
because of bad trigger timing
  
  50   Sat Oct 8 14:33:25 2011 Thomas BergauerHPKbaby_stdrun016250k08.10.2011 14:31:40 Crapfalsches config file (single statt
multi6)
 
  
  51   Sat Oct 8 16:35:04 2011 Thomas BergauerHPKbaby_stdrun017 08.10.2011 16:26:10 Crapwrong timing
 
no cooling
  
  77   Wed Feb 22 13:37:11 2012 Christian IrmlerBELLEOrigami Module #4run103100k22.02.2012 13:35:0822.02.2012 13:54:08 CrapSr90, large scintillator, 
HVret @ Origami closed
HVret @ SMU connected
  
  8   Fri Sep 16 11:01:15 2011 Manfred ValentanMicronMicron Baby Modules     Irradiated modules from last year:
COMB-IRRAD: B2Micron_2826_19_Baby4:
combined p-stop, intermediate strips (was
  
  9   Mon Sep 19 17:38:34 2011 Manfred ValentanMicronModule ATOLL-2     Sensor: B2Micron_2826_17_Baby3
p-stop: Atoll, with intermediate
strips
  
  10   Mon Sep 19 17:39:09 2011 Manfred ValentanMicronModule COMM-2     Sensor: B2Micron_2826_17_Baby2
p-stop: Common, with intermediate
strips
  
  11   Mon Sep 19 17:39:55 2011 Manfred ValentanMicronModule COMB-2     Sensor: B2Micron_2826_17_Baby4
p-stop: Combined with intermediate
strips
  
  12   Mon Sep 19 17:40:47 2011 Manfred ValentanMicronModule SPRAY-2     Sensor: B2Micron_2825_05_Baby4
p-stop: p-spray WITHOUT intermediate
strips
  
  13   Mon Sep 19 17:41:27 2011 Manfred ValentanMicronModule SPRAY-I-2     Sensor: B2Micron_2825_15_Baby3
p-stop: p-spray WITH intermediate
strips
  
  14   Mon Sep 19 17:42:01 2011 Manfred ValentanMicronModule SPRAY-1     Sensor: B2Micron_2825_05_Baby3
p-stop: p-spray WITHOUT intermediate
strips
  
  15   Mon Sep 19 17:42:39 2011 Manfred ValentanMicronModule SPRAY-I-1     Sensor: B2Micron_2825_15_Baby2
p-stop: p-spray WITH intermediate
strips
  
  16   Mon Sep 19 17:44:00 2011 Manfred ValentanMicronModule COMM-1     Sensor: B2Micron_2826_19_Baby2 (reused
from last year, was TRK7)
p-stop: Common, with intermediate
  
  17   Mon Sep 19 17:44:39 2011 Manfred ValentanMicronModule COMB-1     Sensor: B2Micron_2826_01_Baby4 (reused
from last year, was TRK6)
p-stop: Combined, with intermediate
  
  18   Mon Sep 19 17:46:07 2011 Manfred ValentanMicronModule ATOLL-1     Sensor: B2Micron_2826_07_Baby3 (reused
from last year, but was not used in beam
test SPS2010) 
  
  19   Mon Sep 19 17:47:11 2011 Manfred ValentanMicronModule COMB-IRRAD     Sensor: B2Micron_2826_19_Baby4 (reused
from last year, was DUT4, module is irradiated
to 700 kGy)
  
ELOG V3.1.5-fc6679b