Message ID: 32     Entry time: Wed Oct 5 12:09:00 2011
Author: Christian Irmler 
Project: BELLE 
Subject: Origami stack cooled wrong I2C settings 
Run Number: cal005 
Events: 83800 
StartTime: 05.10.2011 12:04:50 
EndTime: 05.10.2011 12:37:11 
Data: Crap 

This calibration file can not be used, due to wrong I2C settings!

Origami6
HV=+-40V
beam on

CO2 cooling: 
preassure @ P_TT_4 = 18.77 bar
mass flow = 0.9 g/s

I=22.45µA

longterm files (same files used for cal005 and run006):
It-pos-0510111122.txt 
It-neg-0510111122.txt  

currents and temperatures:
05.10.2011  12:05:53  event=2883  rate=37events/s temp/curr=35.0/-05.6 35.0/-06.3 35.0/-06.9 34.2/001.9 34.1/002.5 34.1/022.6
05.10.2011  12:36:53  event=83350  rate=48events/s temp/curr=34.4/-05.5 34.5/-06.1 34.5/-06.9 33.9/001.7 33.9/002.4 33.9/022.5
 