| ID | Date | Author | Project | Subject  | Run Number | Events | StartTime | EndTime | Data | 
| 45 | Fri Oct  7 18:28:53 2011 | Christian Irmler | common | run schedule |  |  |  |  | Unknown | 
|  | 
| Attachment 1: run_schedule.pdf | 
| Attachment 2: run_schedule.xlsx | 
| 70 | Thu Oct 13 13:08:38 2011 | Thomas Bergauer | common | end of success |  |  |  |  | Unknown | 
|  | 
| 50 | Sat Oct  8 14:33:25 2011 | Thomas Bergauer | HPK | baby_std | run016 | 250k | 08.10.2011  14:31:40 |  | Crap | 
| falsches config file (single statt multi6)   no coolingbeam on; xy table position x=322  y=80
 HV=200V Istart_PY=7.6uA;  Istart_N=0.42
 std. I2C settings
 | 
| 51 | Sat Oct  8 16:35:04 2011 | Thomas Bergauer | HPK | baby_std | run017 |  | 08.10.2011  16:26:10 |  | Crap | 
| wrong timing   no coolingbeam on; xy table position x=322  y=80
 HV=200V Istart_PY=7.6uA;  Istart_N=0.42
 std. I2C settings
 | 
| 52 | Sat Oct  8 16:45:14 2011 | Thomas Bergauer | HPK | baby_std | run018 | 150000 | 08.10.2011  16:44:13 | 08.10.2011 19:33:33 | Good | 
| no coolingbeam on; xy table position x=322  y=80
 HV=200V Istart_PY=8.2uA;  Istart_N=0.45uA
 std. I2C settings, now with correct timing
 | 
| 53 | Sat Oct  8 20:33:58 2011 | Karl-Heinz Hoffmann | HPK | baby_std | run019 | 150000 | 08.10.2011  20:22:45 | 08.10.2011 23:19:23 | Good | 
| no coolingbeam on; xy table position x=333  y=80
 HV=200V Istart_PY=8.2uA;  Istart_N=0.45uA
 std. I2C settings
 | 
| 54 | Sat Oct  8 23:27:44 2011 | Karl-Heinz Hoffmann | HPK | baby_std | run020 | 382000 | 08.10.2011  23:24:16 | 09.10.2011  09:24:20 | Good | 
| no coolingbeam on; xy table position x=327,5  y=65
 HV=200V Istart_PY=8.2uA;  Istart_N=0.45uA
 std. I2C settings
 | 
| 55 | Sun Oct  9 10:05:34 2011 | Markus Friedl | HPK | baby_std | cal010 | 83800 | 08.10.2011  13:36:25 | 08.10.2011  13:54:07 | Good | 
| HV=+-40V, no cooling
 beam off; xy table position x=  y=
 HV= Istart=uA;
 std. I2C settings
 
 | 
| 56 | Sun Oct  9 10:13:11 2011 | Karl-Heinz Hoffmann | HPK | baby_add | cal011 | 83800 | 09.10.2011  10:05:01 |  | Good | 
| no coolingbeam on; xy table position x=  y=
 HV=200V Istart_P=1.5uA;  Istart_N=0.22uA
 std. I2C settings
 | 
| 57 | Sun Oct  9 11:00:33 2011 | Karl-Heinz Hoffmann | HPK | baby_add | run021 | 150000 | 09.10.2011  10:56:47 | 09.10.2011 12:47:23 | Good | 
| no coolingbeam on; xy table position x=330  y=74
 HV=200V Istart_PY=1,9uA;  Istart_N=0.27uA
 std. I2C settings
 | 
| 60 | Sun Oct  9 13:12:32 2011 | Karl-Heinz Hoffmann | HPK | baby_add | run022 | 670k | 09.10.2011  13:09:32 | 10.10.2011  00:48:16 | Good | 
| no coolingbeam on; xy table position x=330  y=64
 HV=200V Istart_PY=1,9uA;  Istart_N=0.27uA
 std. I2C settings
 | 
| 61 | Mon Oct 10 00:50:23 2011 | Christian Irmler | HPK | baby_add | run023 | 680k | 10.10.2011  00:51:26 | 10.10.2011 09:15:35 | Good | 
| no coolingbeam on; xy table position x=330  y=74
 HV=200V Istart_PY=1,9uA;  Istart_N=0.27uA
 std. I2C settings
 same as run021, but taking more events | 
| 21 | Mon Oct  3 20:30:14 2011 | Thomas Bergauer | common | XY Tisch |  |  |  |  |  | 
| Grosser (DESY) Tisch:  x = -342.0    y = 343.0  (Einheiten unbekannt, möglicherweise mm) Raten-Scan siehe gescannter Zettel im Attachment.   erster Wert: X, also horizontal (positive Zahlen: Saleve side = Restaurant Nr. 3) zweiter Wert: Z, also Höhe (positive Zahlen nach unten) Micron DUT: X:324, Z:103 [Einheiten in mm]   configuration: IP-Address 192.168.0.13; 2 Achsen | 
| Attachment 1: xy-tisch-control.JPG | 
|  | 
| Attachment 2: desy_xy_table.jpg | 
|  | 
| 36 | Wed Oct  5 19:33:40 2011 | Markus Friedl | common | Trigger condition |  |  | 4.10.2011  15:00 |  |  | 
| Changed trigger such that off-spill scintillator triggers are vetoed. Inserted Flip-Flop which is set by begin of spill (WWE) and reset by end of spill signal (EE). Out-bar is put in coincidence with the scintillator trigger. This also changes the timing, which was unfortunately not detected until 30 hours later. Thus, runs 4-7 have bad (wrong) timing -> UNUSABLE | 
| Attachment 1: trigger_path_with_veto.png | 
|  | 
| 71 | Thu Oct 20 11:49:14 2011 | Markus Friedl | common | Scintillator dimensions |  |  |  |  | Good | 
|  | 
| Attachment 1: bhihagag.jpg | 
|  | 
| Attachment 2: bdgaegba.jpg | 
|  | 
| 32 | Wed Oct  5 12:09:00 2011 | Christian Irmler | BELLE | Origami stack cooled wrong I2C settings | cal005 | 83800 | 05.10.2011  12:04:50 | 05.10.2011  12:37:11 | Crap | 
| This calibration file can not be used, due to wrong I2C settings! Origami6HV=+-40V
 beam on
 CO2 cooling: preassure @ P_TT_4 = 18.77 bar
 mass flow = 0.9 g/s
 I=22.45µA longterm files (same files used for cal005 and run006): It-pos-0510111122.txt
 It-neg-0510111122.txt
 currents and temperatures:05.10.2011  12:05:53  event=2883  rate=37events/s temp/curr=35.0/-05.6 35.0/-06.3 35.0/-06.9 34.2/001.9 34.1/002.5 34.1/022.6
 05.10.2011  12:36:53  event=83350  rate=48events/s temp/curr=34.4/-05.5 34.5/-06.1 34.5/-06.9 33.9/001.7 33.9/002.4 33.9/022.5
 
 | 
| 33 | Wed Oct  5 13:00:41 2011 | Christian Irmler | BELLE | Origami stack cooled | run006 | 24692 | 05.10.2011  12:55:53 | 05.10.2011  14:05:49 | Crap | 
| Run stopped after 24692 events, because all n-side APV failed due to a shortcut of a capacitor (C223) on n-side rebo Origami6HV=+-40V
 beam on
 CO2 cooling: preassure @ P_TT_4 = 18.77 bar
 mass flow = 0.9 g/s
 I=22.25µA longterm files (same files used for cal005 and run006): It-pos-0510111122.txt
 It-neg-0510111122.txt
 currents and temperatures:05.10.2011  12:56:54  event=985  rate=0events/s temp/curr=35.0/-05.5 35.0/-06.1 34.9/-06.9 34.2/001.7 34.3/002.4 34.3/022.3
 
 | 
| 37 | Wed Oct  5 19:57:15 2011 | Christian Irmler | BELLE | Origami stack cooled | run007 | 17845 | 05.10.2011  18:27:51 | 05.10.2011  19:31:43 | Crap | 
| Run stopped after 17845 events, because of bad trigger timing
 Origami6HV=+-40V
 beam on
 CO2 cooling: preassure @ P_TT_4 = 18.77 bar
 mass flow = 0.9 g/s
 I=20µA longterm files (same files used for cal005 and run006): It-pos-0510111531.txt
 It-neg-0510111531.txt
 currents and temperatures:05.10.2011  19:30:51  event=17469  rate=0events/s temp/curr=35.6/-05.6 35.6/-06.1 35.6/-07.1 35.1/001.9 35.1/002.4 35.1/020.9
 
 | 
| 34 | Wed Oct  5 16:43:00 2011 | Christian Irmler | BELLE | Origami stack cooled | cal006 | 83800 | 05.10.2011  16:40:18 | 05.10.2011  17:12:27 | Good | 
| Origami6HV=+-40V
 beam on
 CO2 cooling: preassure @ P_TT_4 = 18.2 bar
 mass flow = 0.9 g/s
 I=21.8µA longterm files (same files used for cal005 and run006): It-pos-0510111531.txt
 It-neg-0510111531.txt
 currents and temperatures:05.10.2011  16:41:21  event=2850  rate=50events/s temp/curr=35.4/-05.8 35.3/-06.3 35.4/-07.2 34.9/002.0 34.9/002.5 34.9/021.7
 05.10.2011  17:11:20  event=81237  rate=37events/s temp/curr=35.1/-05.8 35.1/-06.1 35.0/-07.1 34.5/002.0 34.5/002.5 34.5/021.4
 
 | 
| 35 | Wed Oct  5 17:54:09 2011 | Christian Irmler | BELLE | Origami stack cooled | cal007 | 83800 | 05.10.2011  17:51:57 |  | Good | 
| I2C setting modified to improve the shape of the p-side signal --> shaping time reduced, pulse height still low Origami6HV=+-40V
 beam on
 CO2 cooling: preassure @ P_TT_4 = 18.2 bar
 mass flow = 0.9 g/s
 I=18.0µA longterm filesIt-pos-0510111531.txt
 It-neg-0510111531.txt
 currents and temperatures:05.10.2011  17:53:00  event=2900  rate=47events/s temp/curr=35.3/-05.6 35.3/-06.0 35.3/-06.9 34.6/001.9 34.8/002.2 34.8/020.7
 
 |