Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS October 2011  Not logged in ELOG logo
Message ID: 36     Entry time: Wed Oct 5 19:33:40 2011
Author: Markus Friedl 
Project: common 
Subject: Trigger condition 
Run Number:  
Events:  
StartTime: 4.10.2011 15:00 
EndTime:  
Data:  

Changed trigger such that off-spill scintillator triggers are vetoed.

Inserted Flip-Flop which is set by begin of spill (WWE) and reset by end of spill signal (EE). Out-bar is put in coincidence with the scintillator trigger.

This also changes the timing, which was unfortunately not detected until 30 hours later. Thus, runs 4-7 have bad (wrong) timing -> UNUSABLE

Attachment 1: trigger_path_with_veto.png  389 kB  Uploaded Wed Oct 5 21:34:27 2011  | Hide | Hide all
trigger_path_with_veto.png
ELOG V3.1.5-fc6679b