Wed Oct 6 10:15:26 2010, Marko Dragicevic, Micron Baby, XY Positions After Irradiation, , , ,
|
center position: 119/50/(7.5)
top left (direction jura, bottom right on sensor): 127/56.5/7.5
bottom right (direction saleve, top left on sensor): 111/43.5/7.5 |
Wed Oct 6 11:03:59 2010, Marko Dragicevic, Micron Baby, cal, cal013, 83800, 06.10.2010 11:03:12,
|
8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off |
Wed Oct 6 23:02:09 2010, Marko Dragicevic, common, Beam Configuration, , , ,
|
Beam Settings and Profile on 5.10.2010 - 17:00h
Saved as: H6B.801 |
Wed Oct 6 23:03:15 2010, Marko Dragicevic, BELLE, cal, cal014, 83800, 06.10.2010 23:01:56, 06.10.2010 23:34:07
|
Belle stack without Origami2
HV=80V I=227uA
beam on |
Thu Sep 23 15:32:28 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR, , , , 6x
|
p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen |
Thu Sep 23 15:37:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate, , , , 6x
|
p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...) |
Thu Sep 23 15:54:20 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING, , , , 6x
|
p-side: Hybrid 47
alles ok
n-side: Hybrid 38 |
Thu Sep 23 16:00:31 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby2 -> TRACKING, , , , 6x
|
p-side: Hybrid 46
alles ok
n-side: Hybrid 37 |
Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , , 6x
|
p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus
n-side: Hybrid 30 |
Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , , 6x
|
p-side: Hybrid 41
alles ok
n-side: Hybrid 31 |
Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , , 6x
|
p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht |
Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , , 6x
|
p-side: Hybrid 44
alles ok
n-side: Hybrid 34 |
Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , , 6x
|
p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33 |
Fri Sep 24 12:09:32 2010, Manfred Valentan, BELLE, gds-file of Micron wafer, , , ,
|
|
Fri Oct 1 10:06:59 2010, Manfred Valentan, Micron Baby, run, run021, 75000, 01.10.2010 10:07:37, 01.10.2010 15:24:44
|
micron baby: 4 DUTs
HV=100V I=10.9uA (beginning) 13.6uA (end of run)
Beam on |
Sun Oct 3 22:53:49 2010, Manfred Valentan, Pt, run, run033, 25600, 03.10.2010 22.47:38, 04.10.2010 00:02:37
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A |
Mon Oct 4 00:08:55 2010, Manfred Valentan, Pt, run, run034, 187000, 04.10.2010 00:03:18, 04.10.2010 09:22:07
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=21.9A h02=7.5A |
Mon Oct 4 09:31:25 2010, Manfred Valentan, Pt, run, run035, 25600, 04.10.2010 09:28:40,
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A |
Mon Oct 4 14:15:22 2010, Manfred Valentan, Pt, run, run040 --> unusable --> no bias, 25600, 04.10.2010 14:?:?, 04.10.2010 14:32:14
|
Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A |
Mon Oct 4 23:12:16 2010, Manfred Valentan, BELLE, run, run44, 30000, 04.10.2010 23:?:?, 04.10.2010 23.57.23
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C |
|