  89   Wed Oct 6 10:15:26 2010 Marko DragicevicMicron BabyXY Positions After Irradiation    center position: 119/50/(7.5)
top left (direction jura, bottom
right on sensor): 127/56.5/7.5
  
  90   Wed Oct 6 11:03:59 2010 Marko DragicevicMicron Babycalcal0138380006.10.2010 11:03:12 8 x Micron Baby (3 irradiated), no cooling
HV=100V I=115uA (start of run)
beam off
  
  94   Wed Oct 6 23:02:09 2010 Marko DragiceviccommonBeam Configuration    Beam Settings and Profile on 5.10.2010
- 17:00h
Saved as: H6B.801
 BeamProfile.gifBeamMagnets.gifBeamColli.gif 
  95   Wed Oct 6 23:03:15 2010 Marko DragicevicBELLEcalcal0148380006.10.2010 23:01:5606.10.2010 23:34:07Belle stack without Origami2
HV=80V I=227uA
beam on
  
  3   Thu Sep 23 15:32:28 2010 Manfred ValentanMicron BabyModul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR    p-side: Hybrid 42
APV2: viele gerissene bonds der inneren
Bondreihe
 6x 
  4   Thu Sep 23 15:37:54 2010 Manfred ValentanMicron BabyModul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate    p-side: Hybrid 48
alles ok
n-side: Hybrid 35 (wurde repariert,
 6x 
  5   Thu Sep 23 15:54:20 2010 Manfred ValentanMicron BabyModul B2Micron_2826_19_Baby3 -> DUT & TRACKING    p-side: Hybrid 47
alles ok
n-side: Hybrid 38
 6x 
  6   Thu Sep 23 16:00:31 2010 Manfred ValentanMicron BabyModul B2Micron_2826_19_Baby2 -> TRACKING    p-side: Hybrid 46
alles ok
n-side: Hybrid 37
 6x 
  7   Thu Sep 23 16:01:10 2010 Manfred ValentanMicron BabyModul B2Micron_2826_7_Baby3 -> DUT    p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet,
ging sich beim Prototyp-Modul an der Stelle
 6x 
  8   Thu Sep 23 16:12:54 2010 Manfred ValentanMicron BabyModul B2Micron_2826_7_Baby2 -> DUT & TRACKING    p-side: Hybrid 41
alles ok
n-side: Hybrid 31
 6x 
  9   Thu Sep 23 16:19:54 2010 Manfred ValentanMicron BabyModul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING    p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
 6x 
  10   Thu Sep 23 16:22:33 2010 Manfred ValentanMicron BabyModul B2Micron_2826_1_Baby3, TRACKING    p-side: Hybrid 44
alles ok
n-side: Hybrid 34
 6x 
  11   Thu Sep 23 16:23:07 2010 Manfred ValentanMicron BabyModul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING    p-side: Hybrid 43
APV3: Streifen 9 schlecht
n-side: Hybrid 33
 6x 
  12   Fri Sep 24 12:09:32 2010 Manfred ValentanBELLEgds-file of Micron wafer       WaferMicron30.gdsDSSD_layerproperties.lyp 
  51   Fri Oct 1 10:06:59 2010 Manfred ValentanMicron Babyrunrun0217500001.10.2010 10:07:3701.10.2010 15:24:44micron baby: 4 DUTs
HV=100V I=10.9uA (beginning) 
13.6uA (end of run)
 run021_sensordisplay1.jpghit_map_und_cluster.png 
  70   Sun Oct 3 22:53:49 2010 Manfred ValentanPtrunrun0332560003.10.2010 22.47:3804.10.2010 00:02:37Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=22.9A h02=6.9A
  
  71   Mon Oct 4 00:08:55 2010 Manfred ValentanPtrunrun03418700004.10.2010 00:03:1804.10.2010 09:22:07Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=21.9A h02=7.5A
  
  72   Mon Oct 4 09:31:25 2010 Manfred ValentanPtrunrun0352560004.10.2010 09:28:40 Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=24.7A h02=11.8A
  
  77   Mon Oct 4 14:15:22 2010 Manfred ValentanPtrunrun040 --> unusable --> no bias2560004.10.2010 14:?:?04.10.2010 14:32:14Pt modules, angle scan
h01-Pt and h02-Pt
currents: h01=26.0A h02=13.4A
  
  83   Mon Oct 4 23:12:16 2010 Manfred ValentanBELLErunrun443000004.10.2010 23:?:?04.10.2010 23.57.23angle scan Origami 1 and  Micron wedge
1
HV = 100V
  