Tue Sep 28 16:50:31 2010, Thomas Bergauer, common, serial connection chiller, , , ,
|
Der chiller braucht ein gekreuztes serielles Kabel!! |
Tue May 17 19:08:29 2011, Manfred Valentan, Micron Baby, sensors for source test with intermediate strips, , , ,
|
Every second bond of these sensors will be removed to mimic the effect of an intermediate strip. For comparison, this is done both with irradiated and unirradiated sensors.
DUT3: B2Micron_2826_7_baby2, common p-stop, irradiated
DUT4: B2Micron_2826_19_baby4, combined p-stop, irradiated
DUT5: B2Micron_2826_19_baby3, atoll p-stop, irradiated (Wolfgang T. took this sensor to the SEM, it's destroyed by now)
TRK6: B2Micron_2826_1_baby4, combined p-stop, unirradiated
TRK7: B2Micron_2826_19_baby2, common p-stop, unirradiated
B2Micron_2826_7_baby3, atoll p-stop, unirradiated
|
Fri Apr 8 13:25:58 2011, Manfred Valentan, Micron Baby, sensors and modules, , , ,
|
TRK1: B2Micron_2826_1_baby2
TRK2: B2Micron_2826_1_baby3
DUT3: B2Micron_2826_7_baby2 (common p-stop)
DUT4: B2Micron_2826_19_baby4 (combined p-stop)
DUT5: B2Micron_2826_19_baby3 (atoll p-stop)
TRK6: B2Micron_2826_1_baby4
TRK7: B2Micron_2826_19_baby2
GEW: B2Micron_2826_7_baby4
not used: B2Micron_2826_7_baby3 |
Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33
|
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on
chiller is set to 15°C (module temperature is ~17°C)
both Origamis and both Microns are serially cooled
position:centered in both axes 55 / 30 / 277.5
telescope: run20076 (in zero suppressed mode) |
Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,
|
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC |
Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14
|
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5
corresponds to telescope run 20078 |
Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31
|
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079 |
Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12
|
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
telescope run: 20080 |
Tue Sep 28 23:23:47 2010, Markus Friedl, BELLE, run, run006, 2003, 28.09.2010 23:13:22, 28.09.2010 23:22:26
|
channels swapped -> stopped |
Tue Sep 28 23:24:35 2010, Markus Friedl, BELLE, run, run007, 1460, 28.09.2010 23:23:29, 28.09.2010 23:27:54
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20082
sensor config bug (only relevant for sensor display) found -> stopped |
Tue Sep 28 23:29:50 2010, Markus Friedl, BELLE, run, run008, 140000, 28.09.2010 23:29:01, 29.09.2010 09:36:58
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered again
telescope run 20083 |
Wed Sep 29 10:30:59 2010, Markus Friedl, BELLE, run, run009, 30000, 29.09.2010 10:27:27, 29.09.2010 11:06:35
|
zero suppressed (HIT4) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT4
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20084 |
Wed Sep 29 11:09:10 2010, Markus Friedl, BELLE, run, run010, 30000, 29.09.2010 11:08:03, 29.09.2010 11:50:07
|
zero suppressed (HIT5) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT5
HV=100V, Ibias=28A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
modified I2C settings for cooled modules
centered in both axes
telescope run 20085 |
Wed Sep 29 11:53:16 2010, Erik Huemer, BELLE, run, run011, 19003, 29.09.2010 12:19:57, 29.09.2010 14:00:57
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=83.22µA, beam on
no cooling
Temp. at modules:
Origami 1: 50°C
Micron 1: 46°C
Micron 2: 48°C
Origami 2: 48°C
standard I2C settings
centered
telescope run 20085 (continued) |
Wed Sep 29 19:01:28 2010, Markus Friedl, Micron Baby, run, run012, 2248, 29.09.2010 18:59:09, 29.09.2010 19:07:02
|
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/55/7.5
telescope run 20105 |
Wed Sep 29 19:08:56 2010, Markus Friedl, Micron Baby, run, run013, 89853, 29.09.2010 19:09:57, 30.09.2010 00:52:39
|
micron baby stack
HV=100V I=11.0uA
Beam on
telescope position: 121/53.5/7.5 (shifted in height by -1.5mm wrt run012 for better DUT centering)
telescope run 20107 |
Thu Sep 30 00:56:32 2010, Markus Friedl, Micron Baby, run, run014, 100k, 30.09.2010 00:55:30, 30.09.2010 11:20:02
|
micron baby stack
HV=100V I=11.0uA
I_end = 16uA
Beam on
telescope position: 105/40.5/7.5
telescope run 20108 |
Thu Sep 30 14:45:16 2010, Thomas Bergauer, Micron Baby, run, run015, 22.5k, 30.09.2010 13:18:11, 30.09.2010 14:38:01
|
micron baby stack angle scan 15 grad mit 3 modulen
HV=100V, I=3.8uA
Beam on
telescope position: 129/76/187.5
telescope run 20109 |
Thu Sep 30 15:39:53 2010, Markus Friedl, Micron Baby, run, run016, 31k, 30.09.2010 15:38:26, 30.09.2010 17:44:36
|
micron baby: 4 DUTs
HV=100V I=10.3uA (start of run); I=16.2uA (end of run)
Beam on
reference run @ 0°
telescope run 20110 |
Thu Sep 30 18:12:53 2010, Markus Friedl, Micron Baby, run, run017, 35000, 30.09.2010 18:11:53, 30.09.2010 20:22:43
|
micron baby: 4 DUTs
HV=100V I=13.5uA, I_stop=17uA
Beam on
15° rotation
telescope run 20111 |
|