Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-rd50-desy-Oct2024 testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  HEPHY logbook for testbeam at SPS September/October 2010, Page 6 of 8  Not logged in ELOG logo
Entry  Wed May 18 14:42:49 2011, Manfred Valentan, Micron Baby, TRK6, source run, unirrad, postzupf, run115, 100k, 18.05.2011 13:53:54, 18.05.2011 13:53:54 6x

TRK6: B2Micron_2826_1_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK6/postzupfzupf/micronbaby_multi6_postzupf.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.7µA
I_end=1.8µA

Every second bond zupfed. However, there was a mistake and the first ~60 channels are shifted by 1, see attachment!

Entry  Tue May 17 13:31:32 2011, Manfred Valentan, Micron Baby, TRK2, source run, unirrad, prezupf, cal108, 83800, 17.05.2011 13:17:17, 17.05.2011 13:25:27 

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.0µA
I_end=1.3µA

Entry  Tue May 17 14:01:45 2011, Manfred Valentan, Micron Baby, TRK2, source run, unirrad, prezupf, run108, 100k, 17.05.2011 13:28:48, 17.05.2011 13:51:16 run108_all_hits_apv4.pngrun108_all_hits_apv5.pngcal108_pednoise_apv4.pngcal108_pednoise_apv5.png

No DUT candidate (atoll p-stop)

TRK2: B2Micron_2826_1_baby3 (atoll p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK2/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=2µA

n-side: APV4 most strips unusable, no DUT candidate

Entry  Tue May 17 13:02:34 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, cal107, 83800, 17.05.2011 12:20, 17.05.2011 12:35 

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

Entry  Tue May 17 13:08:08 2011, Manfred Valentan, Micron Baby, TRK1, source run, unirrad, prezupf, run107, 100k, 17.05.2011 12:39:34, 17.05.2011 13:03:05 run107_all_hits_apv4.pngrun107_all_hits_apv5.pngcal107_pednoise_apv4.pngcal107_pednoise_apv5.png

DUT candidate common p-stop

TRK1: B2Micron_2826_1_baby2 (common p-stop)
config file: D:/cern10/micronbaby/data_lab/TRK1/prezupf/micronbaby_multi6.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.1µA
I_end=2µA

n-side: half of zones 1 and 4 obsolete due to noisy strips, rest is okay. DUT Candidate

Entry  Mon Sep 27 15:42:09 2010, Thomas Bergauer, common, TLU: wir stecken auf DUT 3, , , ,  

TLUControl.exe ist auf zenpixell3 unter /home/eudet/eudaq/bin

TLUControl.exe -d 14 -a 12
-dXX Mask for DUT:
1   abgeschnittenes Dummykabel
2   EUDRB hinten
4   EUDRB vorne
8   DUT3(wir)
-t100 internal trigger
-aXX Mask for Szintis:
1   4 mm (front)
2   4 mm (front)
4   9 mm (back)
8   9 mm (back)
Entry  Mon Sep 27 15:41:28 2010, Thomas Bergauer, common, Szintillatoren, , , ,  

1: breit  (1)

2: schmal (2)

3: breit  (4)

4: schmal  (8)

 

AND aus beiden breiten: 5

AND aus beiden schmalen: 10

 

Entry  Fri Oct 8 23:22:32 2010, Manfred Valentan, BELLE, Schnittwinkel barrel vs. slanted, , , ,  

17deg acceptance => Schnittwinkel barrel option = 90-17 = 73deg      ----->  rotary table 80.5

layer zusätzlich slanted um Winkel alpha => Schnittwinkel = 73 - alpha

slant angles: layer 4: 11.9deg => Schnittwinkel 61.1deg       ----->  rotary table 68.6
                     layer 5: 17.2deg => Schnittwinkel 55.8deg       ----->  rotary table 63.3
                     layer 6: 21.1deg => Schnittwinkel 51.9deg       ----->  rotary table 59.4

Im Vergleich mit senkrechtem Durchgang der Teilchen erwarte ich eine Vergrößerung der cluster width um den Faktor tan(Schnittwinkel):

slant layer 4: 1.81
slant layer 5: 1.47
slant layer 6: 1.28
barrel:           3.27

Entry  Thu Sep 30 10:56:34 2010, Christian Irmler, common, Room numbers, , , ,  

Room and telefone numbers.

 

Name Building Room Tel.
Bergi 38 418 70 418 or 162471 (mobile)
Markus 41 021 60 021
Manfred 38 404 70 404
Erik 38 463 70 463
Immanuel 38 313 70 313
Chrisu 39 324

79 324

Marko 39 007 79 007
Paqui 38 107 70 107

 

Entry  Mon Sep 27 15:39:33 2010, Thomas Bergauer, common, PI-XY Table, , , ,  

M-521.dd: (links/rechts)

downstream rechts => pos. limit [0]

downstream links => neg. limit [207]

----------------------

M-511.dd: (oben/unten)

oben [102]

unten [0]

----------------------

M-060.dg: (rotation)

parallel beam [7,5]

 

-------------------------------------------

Remote Control:

lokal ssh tunnel starten:
ssh -g -C -L5959:zenpixelw:5900 eudet@eudetmac001.cern.ch

danach mit "Chicken of the VNC" (von lokalem Mac) VNC auf localhost (port 5959). 

Entry  Thu Sep 23 15:32:28 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby4 -> UNBRAUCHBAR, , , ,  6x

p-side: Hybrid 42
APV2: viele gerissene bonds der inneren Bondreihe
APV3: gerissene bonds innen

n-side: Hybrid 32
APV4: 0-35 fail
APV5: 10-40, 68 fail

 

Entry  Thu Sep 23 16:01:10 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby3 -> DUT, , , ,  6x

p-side: Hybrid 40
APV3: letzte 10 Streifennicht gebondet, ging sich beim Prototyp-Modul an der Stelle nicht aus

n-side: Hybrid 30
APV5: 57-64 schlecht, rebond fail?

ALS DUT GEEIGNET!

 

 

 

 

Entry  Thu Sep 23 16:12:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_7_Baby2 -> DUT & TRACKING, , , ,  6x

p-side: Hybrid 41
alles ok

n-side: Hybrid 31
APV4: Streifen 0, 83 schlecht
APV5: Streifen 64, 88, 126 schlecht

ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!

Entry  Thu Sep 23 16:19:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby4, DUT EINGESCHRAENKT, TRACKING, , , ,  6x

p-side: Hybrid 45
APV0: beide Randstreifen schlecht
APV1: Streifen 0 schlecht
APV3: beide Randstreifen etwas schlechter, nicht schlimm

n-side: Hybrid 36
APV4: 0, 9, 40, 79-85, 97, 102, 124 Sensorfehler?
APV5: 0-30 vereinzelt schlechte Streifen, 115-128 Bonds beruehren
 

ALS DUT AUGENZUDRUECKEN GEEIGNET!
FUER TRACKING GEEIGNET!

 

 

Entry  Thu Sep 23 16:22:33 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby3, TRACKING, , , ,  6x

p-side: Hybrid 44
alles ok

n-side: Hybrid 34
APV4: zur Gaenze schlecht, APV-Fehler?
APV5: beide Randstreifen schlecht

FUER TRACKING GEEIGNET!

 

 

 

 

 

Entry  Thu Sep 23 16:23:07 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_1_Baby2, DUT (eingeschraenkt) & TRACKING, , , ,  6x

p-side: Hybrid 43
APV3: Streifen 9 schlecht

n-side: Hybrid 33
APV4: 0-10 andere Bond-Parameter?, 28&29 erhoehtes noise
APV5: 111-128: 4 schlechte Streifen + common mode correction?

ALS DUT GEEIGNET!
FUER TRACKING GEEIGNET!

 

 

 

 

 

Entry  Thu Sep 23 15:37:54 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby4 -> TRACKING & best DUT candidate, , , ,  6x

p-side: Hybrid 48
alles ok

n-side: Hybrid 35 (wurde repariert, nachdem ein paar bonds dran glauben mussten...)
APV4: 15-25 hoher noise, keine Fehler zu sehen -> Sensorfehler?
APV5: 127&128 kreuzen sich, beim Behebungsversuch mehr Schaden angerichtet -> besser mal die Finger davon lassen!

Entry  Thu Sep 23 15:54:20 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby3 -> DUT & TRACKING, , , ,  6x

p-side: Hybrid 47
alles ok

n-side: Hybrid 38
APV5: Streifen 127 hoher Noise

ALS DUT VERWENDEN!

 

Entry  Thu Sep 23 16:00:31 2010, Manfred Valentan, Micron Baby, Modul B2Micron_2826_19_Baby2 -> TRACKING, , , ,  6x

p-side: Hybrid 46
alles ok

n-side: Hybrid 37
APV4: 70-75 schlecht, nix zu sehen -> Sensorfehler
APV5: 115-128 schlecht, rebond fail?

FUER TRACKING GEEIGNET!

 

 

 

Entry  Tue May 17 17:44:12 2011, Manfred Valentan, Micron Baby, GEW8, source run, unirrad, prezupf, cal111, 83800, 17.05.2011 17:51:50, 17.05.2011 18:00:02 

GEW8: B2Micron_2826_7_baby4 (combined p-stop)
config file: D:/cern10/micronbaby/data_lab/GEW8/prezupf/micronbaby_single.cfg

HV=+-50V
90Sr 1mCi ~centered
I_start=1.3µA
I_end=1.6µA

ELOG V3.1.5-fc6679b