Entry  Tue Sep 28 16:50:31 2010, Thomas Bergauer, common, serial connection chiller, , , ,  
 Der chiller braucht ein gekreuztes serielles Kabel!!
Entry  Tue May 17 19:08:29 2011, Manfred Valentan, Micron Baby, sensors for source test with intermediate strips, , , ,  
Every second bond of these sensors will be removed to mimic the effect of an intermediate strip. For comparison, this is done both with irradiated and
unirradiated sensors.
DUT3: B2Micron_2826_7_baby2, common p-stop, irradiated
Entry  Fri Apr 8 13:25:58 2011, Manfred Valentan, Micron Baby, sensors and modules, , , ,  
TRK1: B2Micron_2826_1_baby2
TRK2: B2Micron_2826_1_baby3
DUT3: B2Micron_2826_7_baby2 (common p-stop)
Entry  Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33 
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V  I=49uA
beam is on
Entry  Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,  
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC
Entry  Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14 
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5
Entry  Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31 
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079
Entry  Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12 
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
 
Entry  Tue Sep 28 23:23:47 2010, Markus Friedl, BELLE, run, run006, 2003, 28.09.2010 23:13:22, 28.09.2010 23:22:26 
channels swapped -> stopped
Entry  Tue Sep 28 23:24:35 2010, Markus Friedl, BELLE, run, run007, 1460, 28.09.2010 23:23:29, 28.09.2010 23:27:54 
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
Entry  Tue Sep 28 23:29:50 2010, Markus Friedl, BELLE, run, run008, 140000, 28.09.2010 23:29:01, 29.09.2010 09:36:58 run008_sensordisplay.jpgrun008_sensordisplay2.jpg
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C
Entry  Wed Sep 29 10:30:59 2010, Markus Friedl, BELLE, run, run009, 30000, 29.09.2010 10:27:27, 29.09.2010 11:06:35 
zero suppressed (HIT4) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT4
HV=100V, Ibias=28A, beam on
Entry  Wed Sep 29 11:09:10 2010, Markus Friedl, BELLE, run, run010, 30000, 29.09.2010 11:08:03, 29.09.2010 11:50:07 
zero suppressed (HIT5) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT5
HV=100V, Ibias=28A, beam on
Entry  Wed Sep 29 11:53:16 2010, Erik Huemer, BELLE, run, run011, 19003, 29.09.2010 12:19:57, 29.09.2010 14:00:57 
Belle stack: Origami-Micron-Micron-Origami 
HV=100V, Ibias=83.22µA, beam on
no cooling
Entry  Wed Sep 29 19:01:28 2010, Markus Friedl, Micron Baby, run, run012, 2248, 29.09.2010 18:59:09, 29.09.2010 19:07:02 
micron baby stack
HV=100V I=11.0uA
Beam on
Entry  Wed Sep 29 19:08:56 2010, Markus Friedl, Micron Baby, run, run013, 89853, 29.09.2010 19:09:57, 30.09.2010 00:52:39 run013_hit.png
micron baby stack
HV=100V I=11.0uA
Beam on
Entry  Thu Sep 30 00:56:32 2010, Markus Friedl, Micron Baby, run, run014, 100k, 30.09.2010 00:55:30, 30.09.2010 11:20:02 
micron baby stack
 
HV=100V I=11.0uA
Entry  Thu Sep 30 14:45:16 2010, Thomas Bergauer, Micron Baby, run, run015, 22.5k, 30.09.2010 13:18:11, 30.09.2010 14:38:01 
micron baby stack angle scan 15 grad mit 3 modulen
HV=100V, I=3.8uA
Beam on
Entry  Thu Sep 30 15:39:53 2010, Markus Friedl, Micron Baby, run, run016, 31k, 30.09.2010 15:38:26, 30.09.2010 17:44:36 eventdisplay_schoen.pngevent_display_nichsoschoen.png
micron baby: 4 DUTs
HV=100V I=10.3uA (start of run);  I=16.2uA (end of run)
Beam on
Entry  Thu Sep 30 18:12:53 2010, Markus Friedl, Micron Baby, run, run017, 35000, 30.09.2010 18:11:53, 30.09.2010 20:22:43 number_of_clusters_telescope.png
micron baby: 4 DUTs
HV=100V I=13.5uA, I_stop=17uA
Beam on