Fri Oct 20 14:11:03 2017, Peter Paulitsch, IFX_200_3e14, run000122, 122, 110000, 75.93, 65.30, -72.55°, Yes, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000122.dat |
Telescope filename |
run000122.raw |
Pedestal filename |
KIT_pedestal_600V_20102017.ped |
Bias voltage |
-600 V |
Dark current |
39 uA |
Sensor temperature |
-6 |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
75.93, 65.30 |
Region of interest |
bias line |
Trigger frequency |
210 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
33.7% |
|
Fri Oct 20 14:09:11 2017, Peter Paulitsch, IFX_200_3e14, run000120, 120, 110000, 75.93, 64.80, -72.55°, Yes, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000120.dat |
Telescope filename |
run000120.raw |
Pedestal filename |
KIT_pedestal_600V_20102017.ped |
Bias voltage |
-600 V |
Dark current |
39 uA |
Sensor temperature |
-6 |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
75.93, 64.80 |
Region of interest |
bias line |
Trigger frequency |
210 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
33.5% |
|
Fri Oct 20 14:05:39 2017, Peter Paulitsch, IFX_200_3e14, run000118, 118, 110000, 75.93, 61.20, -72.55°, Yes, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000118.dat |
Telescope filename |
run000118.raw |
Pedestal filename |
KIT_pedestal_600V_20102017.ped |
Bias voltage |
-600 V |
Dark current |
39 uA |
Sensor temperature |
-6 |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
75.93, 61.20 |
Region of interest |
bias line |
Trigger frequency |
210 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
33.2% |
|
Fri Oct 20 12:15:47 2017, Peter Paulitsch, IFX_200_3e14, run000116, 116, 110000, 75.93, 63.00, -72.55°, Yes, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000116.dat |
Telescope filename |
run000116.raw |
Pedestal filename |
KIT_pedestal_600V_20102017.ped |
Bias voltage |
-600 V |
Dark current |
39 uA |
Sensor temperature |
-6 |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
75.93, 63.00 |
Region of interest |
bias line |
Trigger frequency |
210 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
yes |
Alibava efficiency |
33.2% |
|
Wed Oct 18 13:38:47 2017, Peter Paulitsch, IFX_CenterBias, run000112, 112, 3010000, 122.9, 24.25, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000112.dat |
Telescope filename |
run000112.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
3010000 |
Telescope triggers |
3000000 |
Data synced |
yes |
Table position x/y |
122.9, 24.25 |
Region of interest |
bias line |
Trigger frequency |
157 Hz |
Meas. time |
320 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
53.8% |
|
Wed Oct 18 13:36:50 2017, Peter Paulitsch, IFX_CenterBias, run000109, 109, 110000, 122.9, 25.75, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000109.dat |
Telescope filename |
run000109.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
122.9, 25.75 |
Region of interest |
bias line |
Trigger frequency |
200 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
53.4% |
|
Wed Oct 18 13:34:54 2017, Peter Paulitsch, IFX_CenterBias, run000107, 107, 110000, 122.9, 23.5, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000107.dat |
Telescope filename |
run000107.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
122.9, 23.5 |
Region of interest |
bias line |
Trigger frequency |
200 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
53.4% |
|
Wed Oct 18 13:33:05 2017, Peter Paulitsch, IFX_CenterBias, run000106, 106, 60000, 122.9, 23.5, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000106.dat |
Telescope filename |
run000106.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
60000 |
Telescope triggers |
50000 |
Data synced |
yes |
Table position x/y |
122.9, 23.5 |
Region of interest |
bias line |
Trigger frequency |
200 Hz |
Meas. time |
8 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
53.4% |
|
Wed Oct 18 13:30:58 2017, Peter Paulitsch, IFX_CenterBias, run000104, 104, 110000, 122.9, 23.5, -3.3°, No, Unknown
|
run settings
Parameter |
Value |
Alibava filename |
run000104.dat |
Telescope filename |
run000104.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
122.9, 23.5 |
Region of interest |
bias line |
Trigger frequency |
200 Hz |
Meas. time |
15 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
52.3% |
|
Wed Oct 18 13:29:39 2017, Peter Paulitsch, IFX_CenterBias, run000102, 102, 110000, 122.9, 23.2, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000102.dat |
Telescope filename |
run000102.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
110000 |
Telescope triggers |
100000 |
Data synced |
yes |
Table position x/y |
122.9, 23.8 |
Region of interest |
bias line |
Trigger frequency |
185 Hz |
Meas. time |
17 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
52.3% |
|
Wed Oct 18 12:28:08 2017, Peter Paulitsch, IFX_CenterBias, run000101, 101, 10000, 122.9, 23.8, -3.3°, No, Good
|
run settings
Parameter |
Value |
Alibava filename |
run000101.dat |
Telescope filename |
run000101.raw |
Pedestal filename |
pedestal_17102017 |
Bias voltage |
-100 V |
Dark current |
-160 nA |
Sensor temperature |
24.6 °C |
Latency |
140 [a.u.] |
Alibava triggers |
10000 |
Telescope triggers |
14500 |
Data synced |
yes |
Table position x/y |
122.9, 23.8 |
Region of interest |
bias line |
Trigger frequency |
185 Hz |
Meas. time |
2 min |
Beam energy |
5.6 GeV |
Cooling |
no |
Alibava efficiency |
52.3% |
|
Thu Oct 12 10:06:31 2017, Dominic Bloech, common, Packlist, , , , No, Unknown
|
# Testbeam Packliste
### Alibava stuff
* Alibava Mainboard
* Alibava power supply
* Alibava Modules: IFX_CenterBias, HPK_CenterBias, IFX_baby
* Flatband cable 2x
* Alibava resetbox + Cable
* USB AtoB 2x
* BIAS Cable for BeetleChip
* 2410 SMU + Power + USBtoRS232
* Alibava mounting stuff
### Tools and Stuff
* Labeling machine
* Duct tape
* 2 pairs of wool gloves
* Seitenschneider klein
* USBtoRS232 2x
* Lan cable
* Schiebelehre
* Imbuschlüssel
* Screwdriver set
* Special screwdriver set
* Cutter 2x
* labeling cartridge
* Lemo 16 ns
* Lemo 8 ns 2x
* Lemo 4 ns
* Lemo 2 ns
### PC and stuff
* DAQ PC + Cables
* Monitor + Cables
* Mouse
* Keyboard
### Data Storage
* Toshiba 1TB USB3
* Maxtor 4TB USB3 |
Mon Oct 16 15:01:21 2017, Dominic Bloech, common, Preparations, , , , No, Unknown
|
### General
* Setup was set-up without problems. Pedestral and Calibration runs with ALIBAVA successfully.
** Warning: Trigger Out signal (busy signal) for the TLU is a TTL signal. Whereas the Trigger In signal can be a NIM signal. Either converting signal or adept in the TLU (we adepted the TLU matrix)
** TLU double triggered -> discriminated TLU signal beforehand
* Longterm BIAS Voltage for the IFX CenterBias to -100 V, slow control records IV-behavior in 10 sec steps.
* Security lectures taken
* 3 coincident measurements: 2 PM and the FEI4-Plane are connected to an "and" in the TLU
* Latency of Alibava without FEI4-Plane 133 [a.u] with FEI4 140 [a.u].
** Warning: This is due to the converter from the FEI4 which inverts the signal of the FEI4, this signal is then very noisy and would generate false positive triggers. -> Discriminate -> Long cables and latencies
### Other
* NI-Crate was broken (replaced by DESY) |
|