Message ID: 15     Entry time: Wed Oct 18 13:34:54 2017
Author: Peter Paulitsch 
DUT: IFX_CenterBias 
Subject: run000107 
Run Number: 107 
Events: 110000 
XYPosition: 122.9, 23.5, -3.3° 
Cooling: No 
Data: Good 
run settings
Parameter Value
Alibava filename  run000107.dat
Telescope filename  run000107.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

ELOG V3.1.5-fc6679b