Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter)
Not logged in
List
|
Find
|
Login
|
Help
Message ID:
12
Entry time:
Wed Oct 18 13:29:39 2017
Author:
Peter Paulitsch
DUT:
IFX_CenterBias
Subject:
run000102
Run Number:
102
Events:
110000
XYPosition:
122.9, 23.2, -3.3°
Cooling:
No
Data:
Good
run settings
Parameter
Value
Alibava filename
run000102.dat
Telescope filename
run000102.raw
Pedestal filename
pedestal_17102017
Bias voltage
-100 V
Dark current
-160 nA
Sensor temperature
24.6 °C
Latency
140 [a.u.]
Alibava triggers
110000
Telescope triggers
100000
Data synced
yes
Table position x/y
122.9, 23.8
Region of interest
bias line
Trigger frequency
185 Hz
Meas. time
17 min
Beam energy
5.6 GeV
Cooling
no
Alibava efficiency
52.3%