Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter)
Not logged in
List
|
Find
|
Login
|
Help
Message ID:
11
Entry time:
Wed Oct 18 12:28:08 2017
Author:
Peter Paulitsch
DUT:
IFX_CenterBias
Subject:
run000101
Run Number:
101
Events:
10000
XYPosition:
122.9, 23.8, -3.3°
Cooling:
No
Data:
Good
run settings
Parameter
Value
Alibava filename
run000101.dat
Telescope filename
run000101.raw
Pedestal filename
pedestal_17102017
Bias voltage
-100 V
Dark current
-160 nA
Sensor temperature
24.6 °C
Latency
140 [a.u.]
Alibava triggers
10000
Telescope triggers
14500
Data synced
yes
Table position x/y
122.9, 23.8
Region of interest
bias line
Trigger frequency
185 Hz
Meas. time
2 min
Beam energy
5.6 GeV
Cooling
no
Alibava efficiency
52.3%
ELOG V3.1.5-fc6679b