Thu Apr 20 09:31:58 2017, Axel Koenig, ALiBaVa (IFX), run_008_Irrad_550V.dat, 008, 300000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 638. Bias scan -550V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_008_Irrad_550V.dat |
Telescope run |
638 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-550 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
41.8 uA |
|
Thu Apr 13 11:25:32 2017, Axel Koenig, ALiBaVa (IFX), run_007_IFX_CB_30V.dat, 007, 170000, 109, 4.5, 240, No, Unknown
|
Remarks: Telescope run 513. Bias scan 30 V.
Parameter |
Value |
Alibava run |
run_007_IFX_CB_30V.dat |
Telescope run |
513 |
Triggers |
170000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-30 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
Sat Apr 15 21:18:26 2017, Axel Koenig, ALiBaVa (IFX), run_007_Baby_10V.dat, 007, 450000, 102.5, 22.5, 240, No, Crap
|
Remarks: Telescope run 579. Bias scan 10 V. run crashed. Data vaild up to 274915.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_Baby_10V.dat |
Telescope run |
579 |
Triggers |
450000 |
Alibava trigger eff. |
~24% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-10 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
Mon Apr 17 19:54:08 2017, Axel Koenig, ALiBaVa (IFX), run_007_HPK_CB_150V.dat, 007, 300000, 107, 2.6, 240, No, Unknown
|
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_HPK_CB_150V.dat |
Telescope run |
611 |
Triggers |
300000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
Thu Apr 20 08:42:29 2017, Axel Koenig, ALiBaVa (IFX), run_007_Irrad_500V.dat, 007, 250000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 637. Bias scan -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_007_Irrad_500V.dat |
Telescope run |
637 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
41.5 uA |
|
Thu Apr 13 10:58:57 2017, Axel Koenig, ALiBaVa (IFX), run_006_IFX_CB_20V.dat, 006, 185000, 109, 4.5, 240, No, Unknown
|
Remarks: Telescope run 510. Bias scan 20 V.
Parameter |
Value |
Alibava run |
run_006_IFX_CB_10V.dat |
Telescope run |
510 |
Triggers |
185000 |
Alibava trigger eff. |
~55.6% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-20 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
Mon Apr 17 09:04:02 2017, Axel Koenig, ALiBaVa (IFX), run_006_Baby_100V.dat, 006, k.a., 102.5, 22.5, 230, No, Unknown
|
Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).
Forgot ro record data in elog.
Parameter |
Value |
Alibava run |
run_006_Baby_100V.dat |
Telescope run |
570 |
Triggers |
k.a. |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
Mon Apr 17 19:19:14 2017, Axel Koenig, ALiBaVa (IFX), run_006_HPK_CB_100V.dat, 006, 150000, 107, 2.6, 240, No, Unknown
|
Remarks: Telescope run 610. Bias scan 100 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_006_HPK_CB_100V.dat |
Telescope run |
610 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
Thu Apr 20 07:55:02 2017, Axel Koenig, ALiBaVa (IFX), run_006_Irrad_450V.dat, 006, 250000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 636. Bias scan -450V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_006_Irrad_450V.dat |
Telescope run |
636 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-450 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
38.8 uA |
|
Thu Apr 13 09:23:20 2017, Axel König, ALiBaVa (IFX), run_005_IFX_CB_10V.dat, 005, 285000, 109, 4.5, 240, No, Unknown
|
Remarks: Telescope run 508. Bias scan 10 V.
Parameter |
Value |
Alibava run |
run_005_IFX_CB_10V.dat |
Telescope run |
508 |
Triggers |
285000 |
Alibava trigger eff. |
~36.5% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-10 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
Sat Apr 15 20:12:41 2017, Axel Koenig, ALiBaVa (IFX), run_005_Baby_100V.dat, 005, 250000, 102.5, 22.5, 230, No, Unknown
|
Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_Baby_100V.dat |
Telescope run |
568 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
Mon Apr 17 17:46:38 2017, Axel Koenig, ALiBaVa (IFX), run_005_HPK_CB_50V.dat, 005, 150000, 107, 2.6, 240, No, Unknown
|
Remarks: Telescope run 609. Bias scan 50 V. Bias scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_HPK_CB_50V.dat |
Telescope run |
609 |
Triggers |
150000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-50 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
Wed Apr 19 22:56:07 2017, Axel Koenig, ALiBaVa (IFX), run_005_Irrad_450V.dat, 005, 2800000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 635. Bias scan -450V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing! Run crashed over night. Triggers valid up to 2032867.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_005_Irrad_450V.dat |
Telescope run |
635 |
Triggers |
2800000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-450 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
38.8 uA |
|
Sat Apr 15 19:20:34 2017, Axel Koenig, ALiBaVa (IFX), run_004_Baby_100V.dat, 004, 250000, 102.5, 22.5, 250, No, Unknown
|
Remarks: Telescope run 565. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_Baby_100V.dat |
Telescope run |
565 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
250 deg
|
|
Tue Apr 18 08:04:39 2017, Axel Koenig, ALiBaVa (IFX), run_004_HPK_CB_200V.dat, 004, 250000, 107, 2.6, 250, No, Unknown
|
Remarks: Telescope run 607. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_HPK_CB_200V.dat |
Telescope run |
607 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
250 deg
|
|
Wed Apr 19 22:01:57 2017, Axel Koenig, ALiBaVa (IFX), run_004_Irrad_400V.dat, 004, 250000, 96, 64, 360, No, Unknown
|
Remarks: Telescope run 633. Bias scan -400V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_004_Irrad_400V.dat |
Telescope run |
633 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-400 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
37.5 uA |
|
Wed Apr 12 22:41:08 2017, Axel König, ALiBaVa (IFX), run_003_IFX_CB_100V.dat, 003, 100000, 109, 8.5, 240, No, Unknown
|
Remarks: Beam position on only one chip.
Parameter |
Value |
Alibava run |
run_003_IFX_CB_100V.dat |
Telescope run |
500 |
Triggers |
100000 |
Alibava trigger eff |
? |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 V |
Latency |
132 |
Table x |
109 mm |
table z |
8.5 mm |
table rot |
240 deg (parallel to tele. planes) |
|
Sat Apr 15 18:31:14 2017, Axel Koenig, ALiBaVa (IFX), run_003_Baby_100V.dat, 003, 250000, 102.5, 32.5, 240, No, Unknown
|
Remarks: Telescope run 564. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_Baby_100V.dat |
Telescope run |
564 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
32.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
Mon Apr 17 17:02:34 2017, Axel Koenig, ALiBaVa (IFX), run_003_HPK_CB_200V.dat, 003, 250000, 107, 2.6, 230, No, Unknown
|
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
Tue Apr 18 21:03:42 2017, Axel Koenig, ALiBaVa (IFX), run_003_double_irrad_100V.dat, 003, 3500000, 103, 1, 240, No, Unknown
|
Remarks: Telescope run 625. Both chips. Central position. Run crashed over night.
Collected triggers 2710991.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_003_double_irrad_100V.dat |
Telescope run |
625 |
Triggers |
3500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
103 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
|