ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
66
|
Fri Apr 14 13:21:07 2017 |
Johannes Grossmann | MaPSA | Alignment Check | 66 | 250000 | 0 | No | Unknown |
Telescope 1318
Threshold 100
Mapsa CLK Delay 0
Reference Plane Lost aber Anfang Gut |
75
|
Sat Apr 15 16:52:06 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_Baby_100V.dat | 001 | 250000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).
Position: 102.5, 22.5, 240 (should be the center of the sensor).
Parameter |
Value |
Alibava run |
run_001_Baby_100V.dat |
Telescope run |
562 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
77
|
Sat Apr 15 17:38:58 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_Baby_100V.dat | 002 | 250000 | 102.5, 12.5, 240 | No | Unknown |
Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_Baby_100V.dat |
Telescope run |
563 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
12.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
78
|
Sat Apr 15 18:31:14 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_Baby_100V.dat | 003 | 250000 | 102.5, 32.5, 240 | No | Unknown |
Remarks: Telescope run 564. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_Baby_100V.dat |
Telescope run |
564 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
32.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
79
|
Sat Apr 15 19:20:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_Baby_100V.dat | 004 | 250000 | 102.5, 22.5, 250 | No | Unknown |
Remarks: Telescope run 565. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_Baby_100V.dat |
Telescope run |
565 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
250 deg
|
|
80
|
Sat Apr 15 20:12:41 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_Baby_100V.dat | 005 | 250000 | 102.5, 22.5, 230 | No | Unknown |
Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_005_Baby_100V.dat |
Telescope run |
568 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
230 deg
|
|
88
|
Sun Apr 16 20:22:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_014_Baby_70V.dat | 014 | 250000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 591. Bias scan 70 V.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_014_Baby_70V.dat |
Telescope run |
591 |
Triggers |
250000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-70 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
107
|
Mon Apr 17 17:02:34 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_HPK_CB_200V.dat | 003 | 250000 | 107, 2.6, 230 | No | Unknown |
Remarks: Telescope run 606. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_003_HPK_CB_200V.dat |
Telescope run |
606 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
230 deg
|
|
118
|
Tue Apr 18 08:04:39 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_HPK_CB_200V.dat | 004 | 250000 | 107, 2.6, 250 | No | Unknown |
Remarks: Telescope run 607. Angle scan.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_004_HPK_CB_200V.dat |
Telescope run |
607 |
Triggers |
250000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
250 deg
|
|
130
|
Wed Apr 19 22:01:57 2017 |
Axel Koenig | ALiBaVa (IFX) | run_004_Irrad_400V.dat | 004 | 250000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 633. Bias scan -400V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_004_Irrad_400V.dat |
Telescope run |
633 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-400 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
37.5 uA |
|
132
|
Thu Apr 20 07:55:02 2017 |
Axel Koenig | ALiBaVa (IFX) | run_006_Irrad_450V.dat | 006 | 250000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 636. Bias scan -450V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_006_Irrad_450V.dat |
Telescope run |
636 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-450 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
38.8 uA |
|
133
|
Thu Apr 20 08:42:29 2017 |
Axel Koenig | ALiBaVa (IFX) | run_007_Irrad_500V.dat | 007 | 250000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 637. Bias scan -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_007_Irrad_500V.dat |
Telescope run |
637 |
Triggers |
250000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
41.5 uA |
|
90
|
Sun Apr 16 21:43:15 2017 |
Axel Koenig | ALiBaVa (IFX) | run_015_Baby_100V.dat | 015 | 2500000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 592. Long run, bias voltage 100 V. Long run finished without any problems.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_015_Baby_100V.dat |
Telescope run |
592 |
Triggers |
2500000 |
Alibava trigger eff. |
~60% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg
|
|
143
|
Thu Apr 20 22:19:21 2017 |
Axel Koenig | ALiBaVa (IFX) | run_016_Irrad_500V.dat | 016 | 2500000 | 96, 64, 370 | No | Unknown |
Remarks: Telescope run 648. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
rotation scan.
Telescope chiller turned on (15 deg).
Run finished over night!
Parameter |
Value |
Alibava run |
run_016_Irrad_500V.dat |
Telescope run |
648 |
Triggers |
2500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
370 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|
131
|
Wed Apr 19 22:56:07 2017 |
Axel Koenig | ALiBaVa (IFX) | run_005_Irrad_450V.dat | 005 | 2800000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 635. Bias scan -450V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing! Run crashed over night. Triggers valid up to 2032867.
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_005_Irrad_450V.dat |
Telescope run |
635 |
Triggers |
2800000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-450 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
38.8 uA |
|
8
|
Thu Apr 13 09:23:20 2017 |
Axel König | ALiBaVa (IFX) | run_005_IFX_CB_10V.dat | 005 | 285000 | 109, 4.5, 240 | No | Unknown |
Remarks: Telescope run 508. Bias scan 10 V.
Parameter |
Value |
Alibava run |
run_005_IFX_CB_10V.dat |
Telescope run |
508 |
Triggers |
285000 |
Alibava trigger eff. |
~36.5% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-10 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
113
|
Mon Apr 17 19:54:08 2017 |
Axel Koenig | ALiBaVa (IFX) | run_007_HPK_CB_150V.dat | 007 | 300000 | 107, 2.6, 240 | No | Unknown |
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_007_HPK_CB_150V.dat |
Telescope run |
611 |
Triggers |
300000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-150 |
Latency |
132 |
Table x |
107 mm |
Table z |
2.6 mm |
Tabe rot |
240 deg
|
|
129
|
Wed Apr 19 20:55:36 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_Irrad_300V.dat | 003 | 300000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 632. Bias scan -300V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_003_Irrad_300V.dat |
Telescope run |
632 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-300 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
35.1 uA |
|
134
|
Thu Apr 20 09:31:58 2017 |
Axel Koenig | ALiBaVa (IFX) | run_008_Irrad_550V.dat | 008 | 300000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 638. Bias scan -550V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_008_Irrad_550V.dat |
Telescope run |
638 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-550 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
41.8 uA |
|
137
|
Thu Apr 20 12:55:02 2017 |
Axel Koenig | ALiBaVa (IFX) | run_010_Irrad_650V.dat | 010 | 300000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 640. Bias scan -650V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_010_Irrad_650V.dat |
Telescope run |
640 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-650 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
45.4 uA |
|