Remarks: Telescope run 648. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
rotation scan.
Telescope chiller turned on (15 deg).
Run finished over night!
Parameter |
Value |
Alibava run |
run_016_Irrad_500V.dat |
Telescope run |
648 |
Triggers |
2500000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-500 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
370 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
39.2 uA |
|