46
Fri May 22 12:01:32 2015
Hao Yin
CMC injection LV 10V
Comparison w/o filter (LC) connected to
-z_n side.
Mateo has the results.
45
Thu May 21 18:23:22 2015
Hao Yin
Noise Injection LV cable
(TestNr. 15)
injecting sin wave into LV at different
44
Wed May 20 10:12:12 2015
Hao Yin
Ladder RLC test (CMC Injection)
L5 Ladder Test
folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test
Setup: ladder
43
Tue May 19 14:48:06 2015
Hao Yin
Belle II
module
L6 Noise inJection Runs
L6 Noise inJection Runs
Folder "L6_RLC_Test"
Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg
3 Tests: Injkection to 2.5V 1.25V.
42
Tue May 19 13:42:04 2015
Hao Yin
L6 Noise inJection Setup
Test Nr. 1:
RLC between DockBox and Hybrid
(both side).
41
Tue May 19 13:23:16 2015
Hao Yin
Belle II
system
Calibration
CalibrationRun001
PedestalRun001, FIRRun001,
room temperature,
no noise injection
40
Tue May 19 11:01:29 2015
Hao Yin
Belle II
system
Pedestal
PedestalRun
FIRRun001
Baseline measurement without injections,
50000 event,
16x
39
Tue May 19 10:57:19 2015
Hao Yin
Belle II
system
FIR
FIR filter
first fir filter run:
# 1:[0x[FADC ID] in hex], 2:[APV25
ChannelNr], 3-10:[fir coef in float]
38
Tue May 19 10:08:53 2015
Hao Yin
FADC system setup success
3 FADC. All Channel/APV25 running (except
L3 n first and last -> not connected (bonding))
n-side: all connectors
37
Tue May 19 09:31:50 2015
Hao Yin
Noise Test ITA
Everything works except L3 p-side.
The config file is shown in the
following:
36
Thu Jun 5 10:34:45 2014
Benedikt Würkner
Belle II
source
Silc Module
Silc Angle Measurement 10°
Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles.
35
Thu Jun 5 10:34:29 2014
Benedikt Würkner
Belle II
source
Silc Module
Silc Angle Measurement 7°
Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles.
34
Thu Jun 5 10:34:06 2014
Benedikt Würkner
Belle II
source
Silc Module
Silc Angle Measurement 4°
Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles.
33
Thu Jun 5 10:33:46 2014
Benedikt Würkner
Belle II
source
Silc Module
Silc Angle Measurement 1°
Measured the Silc 03/10 Module using the
Sr90 Source to have a comparison for the
Eta-Distribution at different angles.
32
Fri May 16 11:40:29 2014
Benedikt Würkner
Belle II
source
L3 module
No 6 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
10x
31
Fri May 16 11:38:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 5 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
10x
30
Fri May 16 11:37:05 2014
Benedikt Würkner
Belle II
source
L3 module
No 4 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
10x
29
Fri May 9 16:44:41 2014
Benedikt Würkner
Belle II
source
L3 module
No 3 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
10x
28
Fri May 9 15:12:44 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
10x
27
Thu May 8 16:51:57 2014
Benedikt Würkner
Belle II
source
L3 module
No 2 of 6 room temperature measurements using Sr90 Source (single)
Failed with Error: "***ERROR*** Init
NECO failed, Return code: -32761"
Restarted and it works again