ID |
Date |
Author |
Project |
Measurement Type |
Object ID |
Subject |
Text |
|
26
|
Thu May 8 16:51:03 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (single) | Sr90 Radioactive Source
No cooling
Module position: 0:0(top left) |
10x |
23
|
Wed May 7 18:20:36 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 6 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right) |
10x |
22
|
Wed May 7 17:33:21 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 5 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center) |
10x |
21
|
Wed May 7 16:43:37 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 4 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left) |
10x |
20
|
Wed May 7 15:53:38 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 3 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -59:-20(top right) |
10x |
19
|
Wed May 7 15:04:32 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 2 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -32:-20(top center) |
10x |
18
|
Wed May 7 14:36:29 2014 |
Benedikt Würkner | Belle II | source | L3 module | No 1 of 6 room temperature measurements using Sr90 Source (multi6) | Sr90 Radioactive Source
No cooling
Module position: -5:-20(top left) |
10x |
17
|
Sun Jul 4 05:48:36 2010 |
Christian Irmler | BELLE Upgrade | source | Origami 6 - module 1 | run002: first analysis results | Run name: run002
Run type: 0 (Hardware (Normal Run)) |
7x |
16
|
Wed Oct 7 14:24:06 2009 |
Dieter Uhl | BELLE Upgrade | hybrid | #5 | hybrid-pitchadapter | shorts at upper coat
|
|
15
|
Wed Oct 7 14:23:35 2009 |
Dieter Uhl | BELLE Upgrade | hybrid | #4 | hybrid-pitchadapter | opens at upper coat
|
|
14
|
Tue May 20 14:27:50 2008 |
Markus Friedl | BELLE Upgrade | source | micron | analysis results of source test |
*** NOTE: AFTER THIS MEASUREMENT WE REALIZED
THAT BIASING WAS NOT DONE PROPERLY
|
9x |
13
|
Fri May 9 10:04:26 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 05/05 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.0 nA
Ibias (200 V) = 23.6 nA |
12x |
12
|
Fri May 9 10:00:34 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 03/10 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 18.9 nA
Ibias (200 V) = 25.5 nA |
12x |
11
|
Fri May 9 09:56:15 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 06/03 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 26.5 nA
Ibias (200 V) = 37.8 nA |
12x |
10
|
Wed May 7 19:05:08 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 04/04 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 27.8 nA
Ibias (200 V) = 32.7 nA |
12x |
7
|
Wed May 7 16:12:58 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 12/08 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 22.2 nA
Ibias (200 V) = 26.5 nA |
12x |
8
|
Wed May 7 15:40:07 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 07/07 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 20.2 nA
Ibias (200 V) = 21.9 nA |
12x |
9
|
Wed May 7 15:26:24 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 20/09 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100 V) = 25.1 nA
Ibias (200 V) = 31.4 nA |
12x |
6
|
Wed May 7 15:24:49 2008 |
Christian Irmler | SPS Testbeam June08 | module | module 10/02 | properties (noise, intcal), APVs bonded to the sensor | Module tested with 1 and 2 rows bonded to
the sensor, respectively.
HV = 100 V
Ibias
(100V) = 19.1 nA
Ibias (200V) = 23.7 nA |
12x |
5
|
Wed Apr 30 16:52:17 2008 |
Markus Friedl | BELLE Upgrade | module | micron | micron sensor glued to frame | soeben haben wir den micron-DSSD (double metal
layer) in den 2-teiligen rahmen geklebt und
auf beiden seiten
|
|