Home CMS Production Clean room MedAustron HEPHY testbeams old
electronics module assembly SiDDaTA scratch
  HEPHY logbook of the Electronics Group, Page 1 of 4  Not logged in ELOG logo
Entry  Fri Apr 18 17:23:26 2008, Markus Friedl, SPS Testbeam June08, hybrid, hybrid 01, Noise of hybrid 01, sensor fully bonded, no HV hybrid01_sen_nohv_pednoise_apv0.pnghybrid01_sen_nohv_pednoise_apv1.png
HV bias not yet glued to backplane
Entry  Tue Apr 22 19:34:09 2008, Markus Friedl, SPS Testbeam June08, module, hybrid 01, Properties of hybrid 01, sensor fully bonded, HV=100V 6x
HV bias glued to backplane, HV=100V
Entry  Wed Apr 23 13:37:18 2008, Markus Friedl, SPS Testbeam June08, source, hybrid 01, analysis results of source test vie_run001_cluster_sig_0.gifvie_run001_cluster_noi_0.gifvie_run001_cluster_hit_0.gifvie_run001_cluster_clw_0.gif
Ignore the "KEK November 2007" title - that's a legacy and is already changed :-)

As of now, there is no distinction in 16 separate zones. However, the gaps between the the zones are clearly visible in the Hit Profile, as the edge strips
Entry  Wed Apr 30 16:52:17 2008, Markus Friedl, BELLE Upgrade, module, micron, micron sensor glued to frame 
soeben haben wir den micron-DSSD (double metal layer) in den 2-teiligen rahmen geklebt und auf beiden seiten
temporäre kapton-stückerln aufgeklebt, über die bias appliziert werden kann. nach trocknung und bonden der
bias-verbindungen (montag, 5.5.2008) wird dieser für sensor-tests zur verfügung stehen.
Entry  Tue May 20 14:27:50 2008, Markus Friedl, BELLE Upgrade, source, micron, analysis results of source test 9x

*** NOTE: AFTER THIS MEASUREMENT WE REALIZED THAT BIASING WAS NOT DONE PROPERLY
          HENCE THE RESULTS BELOW ARE NOT RELIABLE 
Entry  Tue May 19 09:31:50 2015, Hao Yin, , , , Noise Test ITA 
Everything works except L3 p-side.

The config file is shown in the following:

### Original Configuration File Name: /home/katsuro/tuxdaq_devel/config/delay_scan.latency_scan.cfg ###
Entry  Tue May 19 10:08:53 2015, Hao Yin, , , , FADC system setup success 
3 FADC. All Channel/APV25 running (except L3 n first and last -> not connected (bonding))

n-side: all connectors

p-side: 0x01: 1, 2, 4 and 0x02, 1 with L3 p and L4 p (Telescope)
Entry  Tue May 19 10:57:19 2015, Hao Yin, Belle II, system, FIR, FIR filter 
first fir filter run:

# 1:[0x[FADC ID] in hex], 2:[APV25 ChannelNr], 3-10:[fir coef in float]

0x1,0,1.13520608876,-0.0660414994664,-0.0344046528212,-0.0160940592489,-0.0188049576486,-0.00405635272718,0.0022422085805,0.0019532245698
Entry  Tue May 19 11:01:29 2015, Hao Yin, Belle II, system, Pedestal, PedestalRun 16x
FIRRun001

Baseline measurement without injections, 50000 event,

room temperature.
Entry  Tue May 19 13:23:16 2015, Hao Yin, Belle II, system, Calibration, CalibrationRun001 
PedestalRun001, FIRRun001,

room temperature,

no noise injection
Entry  Tue May 19 13:42:04 2015, Hao Yin, , , , L6 Noise inJection Setup P1000702.JPGP1000700.JPGP1000699.JPGP1000703.JPGP1000707.JPG
Test Nr. 1:

RLC between DockBox and Hybrid (both side).

Preliminary Test on L6, but all other sensors are connected.
Entry  Tue May 19 14:48:06 2015, Hao Yin, Belle II, module, L6 Noise inJection Runs, L6 Noise inJection Runs 
Folder "L6_RLC_Test"

Configuration file: /mnt/data/ITA_NOISE_TESTS/L6_RLC_Test/SinglePeak_3Fadc.cfg

3 Tests: Injkection to 2.5V 1.25V. ground and their combination
Entry  Wed May 20 10:12:12 2015, Hao Yin, , , , Ladder RLC test (CMC Injection) 
L5 Ladder Test

folder: /mnt/data/ITA_NOISE_TESTS/Ladder_test

Setup: ladder only, noise injection on one hybrid (injection point = cable between hybrid and junction board, see attachment
Entry  Thu May 21 18:23:22 2015, Hao Yin, , , , Noise Injection LV cable P1000717.JPG
(TestNr. 15)

injecting sin wave into LV at different frequencies to analyse the output frequency and noise ground level after the junction borad.
Entry  Fri May 22 12:01:32 2015, Hao Yin, , , , CMC injection LV 10V 
Comparison w/o filter (LC) connected to -z_n side.

Mateo has the results.
Entry  Mon May 25 10:38:03 2015, Hao Yin, Belle II, system, L5 Ladder Emission Test, Emission 
(TestNr: 16)

base line noise measurement are saved in SYSTEM_CHECK_AFTER_WE.
(noise wings at fw n side decreased !!!)
Entry  Mon May 25 20:27:23 2015, Hao Yin, Belle II, system, Caen PS base line measurements,  P1000760.JPGP1000758.JPG
Baseline noise measurements wo injection.

measure noise in both HV and LV.

wings of APV25 using cmc with 128 strip are visible wo injection. (folder CAEN_PS, run name Noise_xxx.dat).
Entry  Wed May 27 09:30:54 2015, Hao Yin, Belle II, system, CAEN PS Primary side,  P1000776.JPGP1000774.JPGP1000777.JPGP1000780.JPG
Measured Primary side of caen wo load (setup attachment 2 and prelimilary res. attachment 1. )

and with load (attachment 3: Load, att. 4 corresponding circuit scheme)
Entry is currently edited by Hao Yin on 255.255.255.255  Entry  Fri May 29 11:47:56 2015, Hao Yin, Belle II, system, PS Filter, Testing PS LV filter and quantifying the required min noise lvl 
Data of this entry is recorded in the folder: LV315kHz_Injections
Injecting noise to LV with a freq. of 314 kHz to emulate Caen PS with KenWood PS.
Entry  Mon Nov 30 15:12:19 2015, Hao Yin, , , , FIR_ADC config 
FIR filter and ADC delay test:
ADC delay and FIR filter with and without cooling to reproduce error detected during CERN beam test 2015.
 
ELOG V3.1.5-fc6679b