Fri Oct 23 08:09:04 2009, Stephan Hänsel, Measurements, Run 11273 - data
|
B=0, TPC inbetween but no TPC readout
Beam: 3GeV
silicon position from TPC-support-ring:
123: x=center, z=56.5 cm (measuring tape: sledge 35cm inside the gap)
116: x=center, z=57 cm (measuring tape: sledge 35cm inside the gap)
2 APVs dead:
apvlatency = 75 (in fedpmc_silc.xml) |
Fri Oct 23 08:02:57 2009, Stephan Hänsel, Measurements, Run 11271 - position run
|
B=0, TPC inbetween but no TPC readout
Beam: 3GeV
moved silicon to center position (~58cm from TPC-support-ring)
2 APVs dead:
apvlatency = 75 (in fedpmc_silc.xml)
2-sensor-module in center
1-sensor-module not exactly in center-position:
12316 -> move out of the magnet 1,5cm
11917 -> move out of the magnet 1cm |
Fri Oct 23 07:57:01 2009, Stephan Hänsel, Measurements, Run 11270 - latency scan
|
B=0, TPC inbetween but no TPC readout
scan from 70 to 120 with 1000 events each
root-diagram -> latency ~ 75
-> set apvlatency in fedpmc_silc.xml to 75 |
Fri Oct 23 07:52:52 2009, Stephan Hänsel, Measurements, Run 11269 - Pedestal Run
|
B=0, TPC inbetween but no TPC readout |
Thu Oct 22 11:18:34 2009, Stephan Hänsel, Setup, Pictures
|
Photo Gallery
zusätliche Photos:
labeled SiLC in front of TPC |
Wed Oct 1 11:42:44 2008, stephan hänsel, Setup, Modulkomponenten
|
MODULE 0
1 Sensor Module (SiLC01):
Hybrid: TEC_6D.2.1 / 30216662133923
Sensor: HPK-ILC-6684-01
2 Sensor Module (SiLC02):
Hybrid: TEC_6D.2.1 / 30216662133993
Sensor Near: HPK-ILC-6684-19
Sensor Far: HPK-ILC-6684-05
MODULE 1
1 Sensor Module (SiLC11b):
Hybrid: TEC_6D.2.1 / 30216662133904
Sensor: HPK-ILC-6684-23
2 Sensor Module (SiLC12):
Hybrid: TEC_6D.2.1 / 30216661605173
Sensor Near: HPK-ILC-6684-34
Sensor Far: HPK-ILC-6684-27
(OLD - 1 Sensor Module (SiLC11):
Hybrid: TEC_6D.2.1 / 30216662133922
Sensor: HPK-ILC-6684-23)
|
Thu Oct 22 08:02:26 2009, Stephan Hänsel, Setup, Electronics
|
HV-Kapton-PIN-assignment
CCUM-to-Module Adapter-Cards
CCUM-to-Module Adapter-Cards Pin-assignment (xls)
schematic of the adopted readout (A.Dierlamm)
TEC-R2-Hybrid |
Mon Nov 2 13:22:50 2009, Stephan Hänsel, Setup, DAQ
|
start data-taking:
ssh xxx@bastion.desy.de -X
ssh xdaq@flctpcikhero1.desy.de -X
-
at PC reboot:
- source xdaq_profile
- cd scripts
- ./fedpmc 0 + ctrl C when ready //initialise the first FED
- ./fedpmc 1 + ctrl C when ready //initialise the second FED
- ./gatecalib //sets adresses for the TSC + gate
- ./setdll 3 5 //sets width of the gate
when controllring newly connected
- source xdaq_profile (if not done before)
- cd scripts
- ./ProgramTest.exe -pci -reset //-> controllring 0x4c90
test of devices:
- source xdaq_profile (if not done before)
- cd scripts
- ./ProgramTest.exe -pci -scanCCU // searches for CCUs
- ./ProgramTest.exe -pci -scantrackerdevice // searches for CCUs and APVs
start xdaq:
- source xdaq_profile (if not done before)
- /opt/firefox/firefox & -> http://ikhero2.desy.de:40000 // not working for now
- ./xdaq.sh -p40000
- reload firefox
HyperDAQ:
- -> Control Panel -> Configure Cluster -> load /home/xdaq/xml/peak_silc.xml
- tick: Configure Cluster
- -> submit
- -> view Applications -> Tracker Supervisor:
- choose run type -> normal
- tick: TLU in physics Run
- type spillsize = 20
- tick: No gate
if xdaq kills itself:
analysis:
- root:
- in /Analysis/AC1Analysis-1.4>
- .L runAna_silc.C
- runAna(pedestalnumber,runnumber)
get file with number of single events in all 4 sensors + HitProfile
- root
- .L readClusterTree_silc.cxx++
- readClusterTree_silc(event number)
|
Tue Nov 3 10:45:01 2009, Stephan Hänsel, Setup, Beam On
|
clear test beam areas:
go to T24 (front area):
- use (red) key from interlock
- go into T24 area, close door, use red key in keyhole next to door -> big red light on
- push the white buttons "Absuche" below the three red "Not Aus" (emergency stop) buttons
- go back to the door, turn key and keep it turned!
- open the door, move out and close it again behind you
- now it is the time to return the key again -> two green lights should go on
go to T24/1 (LPTPC area):
- use (black) key from interlock
- go into T24/1 area, close door, use black key in keyhole next to door -> big red light on
- push the white buttons "Absuche" below the three red "Not Aus" (emergency stop) buttons
- go back to the door, turn key and keep it turned!
- open the door, move out and close it again behind you
- now it is the time to return the key again -> two green lights should go on
power bending magnets:
- choose beam energy according to list sticked to monitor
get beam:
- phone Control Room 3500
- tell them to put the wire into DesyII at the position written in their lock book
open shutter:
- go back to hut
- put back the red and black keys into the interlock
- turn all four keys -> 5 green lights should be on next to each pair of keys
- open shutter T24 with the button "Beam Shutter auf" -> bottom green light next to the keys should go out
- open shutter T24/1 with the button "Beam Shutter auf" -> bottom green light next to the keys should go out
- now you should see beam
-> start data taking
|
Tue Nov 3 11:18:46 2009, Stephan Hänsel, Setup, Beam Off
|
close shutter:
- close shutter T24/1 with the button "Beam Shutter zu" (green) -> bottom green light next to the keys should go on
- close shutter T24 with the button "Beam Shutter auf" (green) -> bottom green light next to the keys should go on
- turn all four keys -> (the top) 4 green lights should go out next to each pair of keys
go to T24/1 (LPTPC area):
- just open the door -> the two green and the big red lights go out
If you do not need the test beam any more:
- open door at test beam area T24 -> the two green and the big red lights go out
- call Control Room 3500
- switch off bending magnets
|
Fri Feb 27 13:34:11 2009, Stephan Hänsel, Measurements, ARCs Noise PIoff + channels 2 repair
|
Noise Peak Inverter Off
(SiLC11b after repair --- b ... 2nd module with same sensors but different hybrid and PA)
|
|
|
|
|
|
|
Noise Pioff [ADC*100] |
optical inspection |
Noise Pioff [ADC*100] |
|
|
1ADC-count entspricht ca 770 e- |
|
1ADC-count entspricht ca 770 e- |
|
CHANNEL |
SiLC01 |
After Repair |
Measurement 06 |
CCU123-16 back Z
repair-action
|
5 |
64 |
|
142 |
non |
6 |
65 |
|
142 |
non |
7 |
80 |
|
135 |
non |
8 |
135 |
good |
72 |
PA-PA rebond |
9 |
80 |
|
133 |
non |
10 |
139 |
good |
77 |
PA-PA rebond |
12 |
139 |
good |
76 |
PA-PA rebond |
15 |
73 |
|
59 |
PA-PA rebond |
21 |
145 |
good |
57 |
PA-PA rebond |
73 |
77 |
|
134 |
non |
74 |
70 |
|
135 |
non |
75 |
137 |
good |
62 |
? PA-PA rebond |
137 |
76 |
|
137 |
non |
236 |
76 |
|
69 |
? PA-PA rebond |
281 |
55 |
|
126 |
non |
453 |
67 |
|
118 |
non |
570 |
63 |
|
61 |
Jakkoo-PA Open |
666 |
64 |
|
134 |
non |
668 |
62 |
|
136 |
non |
715 |
74 |
|
144 |
non |
764 |
67 |
|
134 |
non |
765 |
141 |
good |
66 |
PA-PA rebond |
766 |
145 |
good |
65 |
PA-PA rebond |
768 |
136 |
good |
63 |
PA-PA rebond |
|
|
|
|
|
|
|
|
|
|
CHANNEL |
SiLC02 |
|
|
|
21 |
75 |
Jakkoo-PA Open |
|
CCU123-17 back X
|
63 |
64 |
PA-SE rebond |
|
|
73 |
81 |
? |
|
|
91 |
77 |
PA-PA rebond |
|
|
170 |
69 |
? |
|
|
696 |
72 |
PA-SE rebond |
|
|
704 |
67 |
PA-SE rebond |
|
|
719 |
148 |
SE-SE rebond |
|
|
|
|
|
|
|
|
|
|
|
|
CHANNEL |
SiLC11b |
Measurement 06 |
|
CCU119-17 front Z
|
13 |
80 |
Jakkoo-PA Open |
|
|
153 |
62 |
Jakkoo-PA Open |
|
|
415 |
|
? Remove bond -> IV verbesserung |
|
|
713 |
|
? Remove bond -> IV verbesserung |
|
|
|
|
|
|
|
|
|
|
|
|
CHANNEL |
SiLC12 |
Measurement 02 |
|
CCU119-16 front X
|
3 |
68 |
Jakkoo-PA Open |
|
|
128 |
63 |
? |
|
|
346 |
57 |
APV-PA Open |
|
|
523 |
128 |
? |
|
|
651 |
71 |
Jakkoo-PA Open |
|
|
652 |
72 |
Jakkoo-PA Open |
|
|
653 |
71 |
Jakkoo-PA Open |
|
|
654 |
71 |
Jakkoo-PA Open |
|
|
655 |
71 |
Jakkoo-PA Open |
|
|
675 |
149 |
? |
|
|
767 |
74 |
? Jakkoo-PA Open |
|
|
|