|  Wed Sep 29 18:53:05 2010, Thomas Bergauer, Micron Baby, XY Positions, , , , |  | center position: 113/47/7.5 top left (direction jura): 121/53.5/7.5 bottom right (direction saleve): 105/40.5/7.5 |  |  Thu Sep 30 10:56:34 2010, Christian Irmler, common, Room numbers, , , , |  | Room and telefone numbers.   
    
        
            | Name | Building | Room | Tel. |  
            | Bergi | 38 | 418 | 70 418 or 162471 (mobile) |  
            | Markus | 41 | 021 | 60 021 |  
            | Manfred | 38 | 404 | 70 404 |  
            | Erik | 38 | 463 | 70 463 |  
            | Immanuel | 38 | 313 | 70 313 |  
            | Chrisu | 39 | 324 | 79 324 |  
            | Marko | 39 | 007 | 79 007 |  
            | Paqui | 38 | 107 | 70 107 |    |  |  Thu Sep 30 15:06:28 2010, Markus Friedl, Micron Baby, cal, cal006, 83800, 30.09.2010  15:01:56, |  | micron baby: 4 DUTs - angle scanHV=100V I=6.8uA
 Beam off (turned on at ~8k events)
 
 |  |  Sat Oct  2 15:24:00 2010, Erik Huemer, ITE, XY Position and Slow Control, , , ,   |  | center position: 119/48/187,5   |  |  Sat Oct  2 17:27:14 2010, Thomas Bergauer, ITE, cal, cal007, 83800, 02.10.2010 17:11:18 ,    |  | ITE: 2 DUTs2 x SILC + 2 x ITE
 HV=100V
 
 Beam on  one short only per sensor |  |  Sun Oct  3 08:14:39 2010, Markus Friedl, ITE, cal, cal008, 83800, 03.10.2010  08:13:06, |  | 6 x SILC + 2 x ITEHV=100V
 telescope position: 119
 no beam (technical problem) |  |  Sun Oct  3 14:35:12 2010, Marko Dragicevic, CNM, cal, cal009, 83800, 03.10.2010  13:50:54,     |  | CMN-SILC stackHV_SILC (Katze)=75V, 0.25uA (6 SiLC)
 HV_CNM (Keithley)=30V, CNM_1=84nA, CNM_2=4.3uA
 DUT outside of beam
 calibration started after 1 hour warmup |  |  Sun Oct  3 16:23:20 2010, Erik Huemer, Pt, XY/R Position, , , , |  | centerposition: 119/43/187,5 27 grad: 214,5 |  |  Sun Oct  3 18:23:27 2010, Christian Irmler, Pt, cal, cal010, 83800, 03.10.2010  18:26:49 ,   |  | pt modules angle scanh01-Pt and h02-Pt
 currents: h01=23.1µA h02=10.4µA
 HV=200V
 beam on
 modules flushed with dry air   |  |  Sun Oct  3 18:52:56 2010, Christian Irmler, Pt, run, run030, 25600, 03.10.2010  19:16:29, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=23.1A h02=10.4A
 HV=200V beam on
 angle: 27
 telescope run 20134 |  |  Sun Oct  3 20:44:40 2010, Erik Huemer, Pt, run, run031, 25600, 03.10.2010  19:42:34, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=20.5A h02=6.5A
 HV=200V beam on
 angle: 29
 telescope run 20135 |  |  Mon Oct  4 09:31:25 2010, Manfred Valentan, Pt, run, run035, 25600, 04.10.2010  09:28:40, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=24.7A h02=11.8A
 HV=200V beam on
 angle: 35 deg
 telescope run 20140 |  |  Mon Oct  4 15:39:34 2010, Christian Irmler, Pt, run, run041, 25600, 04.10.2010  15:46:22, |  | Pt modules, angle scan h01-Pt and h02-Ptcurrents: h01=26.0A h02=13.4A
 HV=200V beam on
 angle: 45 deg
 position axis = 232.5
 repetition of run039 telescope run20147 |  |  Mon Oct  4 16:29:36 2010, Christian Irmler, common, beam settings, , , ,    |  | beam settings optimized by beamline operator wire champer display fixed |  |  Mon Oct  4 20:16:19 2010, Christian Irmler, BELLE, cal, cal011, 83800, 04.10.2010  20:15:00, |  | angle scan Origami 1 and  Micron wedge 1HV = 100V
 chiller set to 14°C
 HV connection of Origami 1 repaired |  |  Wed Oct  6 10:15:26 2010, Marko Dragicevic, Micron Baby, XY Positions After Irradiation, , , , |  | center position: 119/50/(7.5) top left (direction jura, bottom right on sensor): 127/56.5/7.5 bottom right (direction saleve, top left on sensor): 111/43.5/7.5 |  |  Wed Oct  6 11:03:59 2010, Marko Dragicevic, Micron Baby, cal, cal013, 83800, 06.10.2010  11:03:12, |  | 8 x Micron Baby (3 irradiated), no coolingHV=100V I=115uA (start of run)
 beam off
 # VADJ/VPSP increased to 48 (was 30) for irradiated DUTs to restore baseline position (higher after irradiation) ADC delay timing did not change after irradiation (verified)
 |  |  Wed Oct  6 23:02:09 2010, Marko Dragicevic, common, Beam Configuration, , , ,     |  | Beam Settings and Profile on 5.10.2010 - 17:00h Saved as: H6B.801 |  |  Fri Oct  8 17:26:36 2010, Markus Friedl, BELLE, cal, cal015, 83800, 08.10.2010  17:22:44, |  | Belle stack without Origami2HV=11V I=32uA
 beam on 2 suspicious APVs on n side of Micron due to burnt strip trying to identify problematic Micron n side channels with low bias voltage (APV22 baseline saturates at higher bias) |  |  Fri Oct  8 23:05:03 2010, Markus Friedl, BELLE, cal, cal016, 83800, 08.10.2010  23:03:16, |  | Belle stack w/o Origami2 after irradiationHV=80V / 258 µA
 cooling: Origami only, chiller set to -25°C,
 2 suspicious APVs on n side of Micron due to burnt strip
 
 Bias connection of Origami repaired --> lower noise on p-side |  |