Fri Sep 24 12:09:32 2010, Manfred Valentan, BELLE, gds-file of Micron wafer, , , ,
|
|
Mon Sep 27 18:54:47 2010, Thomas Bergauer, BELLE, XY Position, , , ,
|
center position: 55/40/277,5 |
Tue Sep 28 01:13:57 2010, Markus Friedl, BELLE, cal, cal001, 83800, 28.09.2010 01:11:20,
|
first intcal with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on |
Tue Sep 28 03:06:31 2010, Markus Friedl, BELLE, run, run001, 119516, 28.09.2010 03:06:04, 28.09.2010 12:18:33
|
first run with complete Belle stack: 2 x Origami, 2 x Micron
HV=100V I=49uA
beam is on |
Tue Sep 28 12:54:33 2010, Markus Friedl, BELLE, run, run002, , 28.09.2010 12:46:54,
|
same as run001 after shifting x by 48mm
103 / 30 / 277.5 ? unsure after crash of xy stage PC |
Tue Sep 28 13:04:02 2010, Markus Friedl, BELLE, run, run003, 25000, 28.09.2010 13:00:05, 28.09.2010 14:41:14
|
now for real (previous run was at wrong position)
all same as run001, except position now still centered on p-strips, but on high edge (last APVs) for n side
position: 103 / 30 / 277.5 |
Tue Sep 28 14:38:24 2010, Christian Irmler, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in |
Tue Sep 28 14:48:00 2010, Markus Friedl, BELLE, run, run004, 1755, 28.09.2010 14:48:28, 28.09.2010 15:06:31
|
same as before, but now pos 1 is located on the other edge (-48mm from center)
telescope 7 / 30 / 277.5
telescope run 20079 |
Tue Sep 28 15:09:16 2010, Markus Friedl, BELLE, run, run005, 40000, 28.09.2010 15:07:08, 28.09.2010 20:20:12
|
previous run stopped due to beam problem (shifted, broad, etc).
now recovered, restarting with same settings.
|
Tue Sep 28 22:07:16 2010, Markus Friedl, BELLE, cal, cal002 DO NOT USE -> go to cal003, 83800, 28.09.2010 22:01:55,
|
Belle stack (Origami, Micron, Micron, Origami)
now cooling only for Origami, Micron are uncooled
chiller set point: -25°C, measured values on Origami: -10°C |
Tue Sep 28 22:09:39 2010, Markus Friedl, BELLE, Temperature sensors Belle stack, , , ,
|
PicoLogic TC-08 temperature sensor assignment Belle stack:
Sensor type: K
channel 1: Origami_mod1_in |
Tue Sep 28 23:23:47 2010, Markus Friedl, BELLE, run, run006, 2003, 28.09.2010 23:13:22, 28.09.2010 23:22:26
|
channels swapped -> stopped |
Tue Sep 28 23:24:35 2010, Markus Friedl, BELLE, run, run007, 1460, 28.09.2010 23:23:29, 28.09.2010 23:27:54
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C |
Tue Sep 28 23:29:50 2010, Markus Friedl, BELLE, run, run008, 140000, 28.09.2010 23:29:01, 29.09.2010 09:36:58
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=38A, beam on
cooling: Origami only, chiller: -25C, Module: -10C |
Wed Sep 29 09:39:33 2010, Markus Friedl, BELLE, cal, cal003, 83800, 29.09.2010 09:38:00,
|
same as cal002, but now with corrected readout order |
Wed Sep 29 10:30:59 2010, Markus Friedl, BELLE, run, run009, 30000, 29.09.2010 10:27:27, 29.09.2010 11:06:35
|
zero suppressed (HIT4) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT4
HV=100V, Ibias=28A, beam on |
Wed Sep 29 11:09:10 2010, Markus Friedl, BELLE, run, run010, 30000, 29.09.2010 11:08:03, 29.09.2010 11:50:07
|
zero suppressed (HIT5) @ FADC
Belle stack: Origami-Micron-Micron-Origami - HIT5
HV=100V, Ibias=28A, beam on |
Wed Sep 29 11:53:16 2010, Erik Huemer, BELLE, run, run011, 19003, 29.09.2010 12:19:57, 29.09.2010 14:00:57
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=83.22µA, beam on
no cooling |
Wed Sep 29 14:03:55 2010, Markus Friedl, BELLE, cal, cal004, 83800, 29.09.2010 14:02:25, 29.09.2010 14:45:05
|
Belle stack: Origami-Micron-Micron-Origami
HV=100V, Ibias=100µA, beam off
no cooling |
Mon Oct 4 20:16:19 2010, Christian Irmler, BELLE, cal, cal011, 83800, 04.10.2010 20:15:00,
|
angle scan Origami 1 and Micron wedge 1
HV = 100V
chiller set to 14°C |
|