ID |
Date |
Author |
Subject |
Run Number |
DUT |
Beam Energy |
Rate Setting |
Particle Type |
Data |
t-Start |
t-Stop |
Duration_min |
Frontend |
Phantom |
Phantom thickness |
165
|
Sat Dec 14 13:40:47 2024 |
Felix Ulrich-Pur | threshold and preamp tests | 26 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:35 | 12:49 | 14 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 10000 (changed threshold)
Diamond: 500mA, threshold 50 |
96
|
Sun Jun 9 01:27:38 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 25 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 01:16 | 01:30 | | | | |
3 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD
WET measurement |
164
|
Sat Dec 14 13:39:15 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 25 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 63.3 MeV/u | Low Flux High | Helium | Good | 12:05 | 12:23 | 18 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
380 kHz with Ramon and only 180kHz TRB, 42ps single channel res prae calib |
95
|
Sun Jun 9 01:26:56 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 24 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 01:02 | 01:14 | | | | |
2 cm dense bone (in isocentre)
2.1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 315 kHz on LGAD
WET measurement |
163
|
Sat Dec 14 13:37:26 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 24 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 73.2 MeV/u | Low Flux High | Helium | Good | 11:42 | 12:00 | 18 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
2MHz with Ramon and only 200kHz TRB |
94
|
Sun Jun 9 01:25:26 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 23 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 00:30 | 01:02 | | | | |
2 cm dense bone (in isocentre)
- Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1 MHz on LGAD
interlock at 00:31 till 00:50 --> 19min break
WET measurement |
162
|
Sat Dec 14 13:35:59 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 23 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 124.4 MeV/u | Low Flux High | Helium | Good | 11:24 | 11:37 | 13 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
5MHz with Ramon and only 500kHz TRB |
93
|
Sun Jun 9 01:22:48 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 22 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 00:14 | 00:23 | | | | |
1 cm dense bone (in isocentre)
2.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 600 kHz on LGAD
WET measurement |
92
|
Sun Jun 9 00:12:41 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Knochen | 21 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 00:00 | 00:14 | | | | |
1 cm dense bone (in isocentre)
4.5 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 1.2 MHz on LGAD
WET measurement |
160
|
Sat Dec 14 13:31:49 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux High | Helium | Good | 10:41 | 10:56 | 15 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
3.5MHz with Ramon and only 600kHz with TRB-52ps single channel res prae calib |
161
|
Sat Dec 14 13:34:18 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 21 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 97.2MeV/u | Low Flux High | Helium | Good | 10:58 | 11:23 | 25 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
3MHz with Ramon and only 300kHz with TRB-44ps single channel res prae calib |
91
|
Sun Jun 9 00:10:38 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 20 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 23:31 | 00:00 | | | | |
5 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 330 kHz on LGAD
14 min break with beam off (DAQ failed, had to power cycle TRB3s and all DIRICH boards-->out of synch DIRICH)
WET measurement |
159
|
Sat Dec 14 13:28:57 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 20 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 147.2 MeV/u | Low Flux Medium | Helium | Good | 10:33 | 10:38 | 5 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
300kHz with Ramon and only 40kHz with TRB--> decision to go to low flux high was made |
73
|
Sat Jun 8 19:56:37 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs Calibrationcurve | 2 | TOF-Cal GSI | 252.7 MeV | Low Flux Medium | Proton | Good | 16:29 | 16:47 | | | | |
1 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 350kHz on LGAD
TOF Calibration Curve |
141
|
Sat Dec 14 12:52:02 2024 |
Felix Ulrich-Pur | Shift 23.11.24 low flux He test with RaMon | 2 | RaMon | 177.8 MeV/u | Low Flux Medium | Helium | Good | 06:31 | 06:32 | 1 | | | |
Mean rate per spill~ 6-8E5 p/s (online estimation without proper analysis) |
90
|
Sun Jun 9 00:08:07 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 19 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 23:20 | 23:30 | | | | |
5 cm plastic water (in isocentre)
3.7 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 795 kHz on LGAD
WET measurement |
158
|
Sat Dec 14 13:26:29 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration | 19 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 177.8 MeV/u | Low Flux Medium | Helium | Good | 10:08 | 10:25 | 17 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
750kHz with Ramon and only 160kHz with TRB, 44ps single channel res preacalib |
89
|
Sun Jun 9 00:07:17 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 18 | TOF-Cal GSI | 145.4 MeV | Low Flux High | Proton | Good | 23:04 | 23:20 | | | | |
4 cm plastic water (in isocentre)
2 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 500 kHz on LGAD
WET measurement |
157
|
Sat Dec 14 13:16:33 2024 |
Felix Ulrich-Pur | Energy vs TOF calibration +Alignment of DOGMA setup | 18 | TOF-Cal GSI (TRB)+DOGMA setup(diamond+LGAD)+RaMon | 205.2 MeV/u | Low Flux Medium | Helium | Good | 09:42 | 09:48 | 6 | | | |
TRB Setup: 260V bias and 250mA pre-amps, threshold 1000
DOGMA setup had to be shifted manually to align it with the beam |
88
|
Sun Jun 9 00:06:01 2024 |
Felix Ulrich-Pur | TOF CAL HADES LGADs WET Messung Wasser | 17 | TOF-Cal GSI | 194.3 MeV | Low Flux High | Proton | Good | 22:53 | 23:04 | | | | |
4 cm plastic water (in isocentre)
3.8 Mhz on Ramon (after 5 Layers of Silicon and close to second iso centre) and 900 kHz on LGAD
WET measurement |