  Belle II and AIDA/Infineon Testbeam at DESY in Jan2014, all entries  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events StartTime EndTime Data Text Attachments
  98   Wed Jan 29 22:40:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos2_002200k29.01.2014 22:4029.01.2014 23:15GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to --8.91097 -22.80061
  
  97   Wed Jan 29 22:36:35 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_pos1_001200k29.01.2014 22:1529.01.2014 22:35GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
Position changed to -3.910970 -17.800610
  
  96   Wed Jan 29 22:08:48 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias Scan  29.01.2014 22:0029.01.2014 22:00GoodAll Infineon Stack 2 runs have been taken
at table position: 1.089030, -12.800610
 
  
  95   Wed Jan 29 22:06:12 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_015200k29.01.2014 19:1529.01.2014 19:45GoodHV at 300V; I at app. 7.5µA 3GeV,
Single mode
 
  
  94   Wed Jan 29 22:03:15 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_014200k29.01.2014 18:1529.01.2014 18:45GoodHV at 260V; I at app. 7.5µA 3GeV,
Single mode
 
  
  93   Wed Jan 29 22:02:04 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_013200k29.01.2014 15:2629.01.2014 17:00GoodHV at 290V; I at app. 8µA 3GeV, Single
mode
 
  
  92   Wed Jan 29 22:01:08 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_012200k29.01.2014 14:2529.01.2014 15:26GoodHV at 280V; I at app. 8µA 3GeV, Single
mode
 
  
  91   Wed Jan 29 21:59:51 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_011200k29.01.2014 13:4529.01.2014 14:20GoodHV at 270V; I at app. 7.6µA 3GeV,
Single mode
 
  
  90   Wed Jan 29 21:57:55 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_010100k29.01.2014 13:2029.01.2014 13:35GoodHV at 260V; I at app. 7.6µA 3GeV,
Single mode
 
  
  89   Wed Jan 29 21:56:58 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_009110k29.01.2014 12:5029.01.2014 13:15GoodHV at 250V; I at app. 7.5µA 3GeV,
Single mode
 
  
  88   Wed Jan 29 21:56:15 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_008200k29.01.2014 12:1529.01.2014 12:45GoodHV at 240V; I at app. 7.5µA 3GeV,
Single mode
 
  
  87   Wed Jan 29 21:55:09 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_007200k29.01.2014 11:5029.01.2014 12:15GoodHV at 230V; I at app. 8µA 3GeV, Single
mode
 
  
  86   Wed Jan 29 12:11:00 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_006200k28.01.2014 20:3028.01.2014 21:00GoodHV at 220V; I at app. 8.5µA 3GeV,
Single mode
 
  
  85   Wed Jan 29 12:10:06 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_005200k28.01.2014 20:0028.01.2014 23:00GoodHV at 210V; I at app. 8.5µA 3GeV,
Single mode
 
  
  84   Wed Jan 29 12:08:52 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_004200k28.01.2014 19:3028.01.2014 20:00GoodHV at 200V; I at app. 9.5µA 3GeV,
Single mode
 
  
  83   Wed Jan 29 12:07:48 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_003200k28.01.2014 17:4028.01.2014 18:20GoodHV at 150V; I at app. 9µA 3GeV, Single
mode
 
  
  82   Wed Jan 29 12:04:53 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_002140k28.01.2014 16:5028.01.2014 17:20GoodHV at 100V; I at app. 8.5µA 3GeV,
Single mode
 
  
  81   Wed Jan 29 12:02:52 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2 Bias ScanHW_Run_Infineon_Stack2_BiasScan_001100k28.01.2014 16:3028.01.2014 16:50GoodHV at 0V; I at app. 5nA 3GeV, Single mode
 
  
  80   Mon Jan 27 12:20:53 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_004800k27.01.2014 09:1027.01.2014 12:15GoodHV at 300V; I at app. 10µA 3GeV,
Single mode
 
  
  79   Sun Jan 26 19:14:07 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_003140 k26.01.2014 18:1026.01.2014 19:15GoodHV at 300V; I at app. 10µA 5GeV,
Single mode
 
  
  78   Sun Jan 26 19:12:42 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_0024 M25.01.2014 22:3026.01.2014 15:15GoodHV at 300V; I at app. 11µA 4GeV,
Single mode
 
  
  77   Sat Jan 25 21:14:46 2014 Wolfgang TreberspurgInfineonMulit 6 mode Run Stack 2HW_Run_Infineon_Stack2_Multi_002230k25.01.2014 19:0025.01.2014 21:15GoodHV 300V, I 10µA
Beam Energy  4GeV
Latency changed to 93
  
  76   Sat Jan 25 18:46:32 2014 Wolfgang TreberspurgInfineonMulit 6 mode Run Stack 2HW_Run_Infineon_Stack2_Multi_001340k25.01.2014 16:3025.01.2014 18:40UnknownHV 300V, I 10µA
Beam Energy changed during the run
between 2GeV - 5GeV - 4GeV
  
  75   Sat Jan 25 18:28:38 2014 Wolfgang TreberspurgInfineonCalibration run Infineon Stack 2Calibration_Run_Infineon_Stack2_0018290025.01.2014 10:1525.01.2014 10:25UnknownHV 300V, I ca. 11µA single mode   
  74   Sat Jan 25 18:24:03 2014 Wolfgang TreberspurgInfineonSingle mode Run Stack 2HW_Run_Infineon_Stack2_0011.05 M25.01.2014 10:3025.01.2014 15:40UnknownHV at 300V; I at app. 11µA 4GeV,
Single mode
Modules centered to beam but no hits
  
  73   Fri Jan 24 18:02:46 2014 Wolfgang TreberspurgInfineonNew Infineon Stack    GoodExchanged AIDA stack with modified Infineon
Stack 
Configuration: 
  
  72   Fri Jan 24 11:23:15 2014 Hao Yin AIDAHW_AIDA0037635624.02.2014 10:3024.02.2014 11:22UnknownHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered) no idea ---
  
  71   Fri Jan 24 11:03:14 2014 Wolfgang TreberspurgAIDAAIDAHW_AIDA002024.01.2014 10:02 CrapTuxDaq crashed   
  70   Fri Jan 24 00:21:16 2014 Hao Yin AIDAHW_AIDA00140k24.02.2014 00:18 UnknownHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered) no idea ---
  
  69   Thu Jan 23 22:47:49 2014 Hao Yin AIDACalibrationRun0018380023.01.2014 13:35:5523.01.2014 02:08:15Goodtaken with tuxdaq...
HV=75V  I=?3.7uA?
position = 0 / -30 mm relative to
  
  68   Sun Jan 19 18:01:46 2014 Christian IrmlercommonAIDA setup operated with TuxDAQ    UnknownNew SIS driver version sis1100-2.13-3 installed
on DAQPC. 
To install the driver call as root:
  
  67   Mon Jan 13 12:02:40 2014 Markus FriedlcommonKontakt    UnknownRichard Thalmeier   Tel. 4801
Hao Yin   
  
  66   Mon Jan 13 01:58:14 2014 Markus FriedlAIDArunrun057900k13.01.2014 01:56:2613.01.2014 10:48:22GoodHV=100V  I=3.7uA
position = 0 / -30 mm relative to
initial (but again centered)
  
  65   Sun Jan 12 18:04:18 2014 Markus FriedlAIDArunrun056510k12.01.2014 17:59:5713.01.2014 01:47:50GoodHV=100V  I=3.7uA
position = -25 / 0 mm relative to
initial
  
  64   Sun Jan 12 10:36:37 2014 Markus FriedlAIDArunrun05531091312.01.2014 10:34:4412.01.2014 15:42:47GoodHV=100V  I=3.6uA
position = 23 / -35 mm relative to
before
  
  63   Sat Jan 11 22:32:19 2014 Markus FriedlAIDArunrun054800k11.01.2014 22:30:4412.01.2014 10:13:10GoodHV=150V  I=5.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  62   Sat Jan 11 20:56:29 2014 Markus FriedlAIDArunrun053100k11.01.2014 20:55:2911.01.2014 22:25:43GoodHV=140V  I=7.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  61   Fri Jan 10 13:04:49 2014 Markus FriedlAIDArunrun052100k10.01.2014 13:04:0510.01.2014 14:30:18GoodHV=130V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  60   Fri Jan 10 11:26:54 2014 Markus FriedlAIDArunrun051100k10.01.2014 11:26:0810.01.2014 12:53:12GoodHV=120V  I=4.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  59   Fri Jan 10 11:02:31 2014 Markus FriedlBelle SVDPower supply  10.01.2014 11:00:00 Unknown   KenWood100114.png 
  58   Fri Jan 10 09:54:11 2014 Markus FriedlAIDArunrun050100k10.01.2014 09:53:1310.01.2014 11:21:12GoodHV=110V  I=4.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  57   Fri Jan 10 08:21:46 2014 Markus FriedlAIDArunrun049100k10.01.2014 08:20:49 10.01.2014 09:49:46GoodHV=100V  I=4.2uA
centered position, HV scan
5GeV beam, 6 samples
  
  56   Fri Jan 10 00:58:46 2014 Markus FriedlAIDArunrun048500k10.01.2014 00:57:4810.01.2014 08:17:57GoodHV=90V  I=3.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  55   Thu Jan 9 23:27:27 2014 Markus FriedlAIDArunrun047100k09.01.2014 23:26:3510.01.2014 00:52:56GoodHV=80V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  54   Thu Jan 9 21:41:20 2014 Markus FriedlAIDArunrun046100k09.01.2014 21:40:2909.01.2014 23:07:16GoodHV=70V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  53   Thu Jan 9 19:37:33 2014 Markus FriedlAIDArunrun045100k09.01.2014 19:36:2109.01.2014 21:01:31 GoodHV=60V  I=3.8uA
centered position, HV scan
5GeV beam, 6 samples
  
  52   Thu Jan 9 18:09:40 2014 Markus FriedlAIDArunrun044100k09.01.2014 18:08:1909.01.2014 19:35:21GoodHV=50V  I=3.6uA
centered position, HV scan
5GeV beam, 6 samples
  
  51   Thu Jan 9 16:36:30 2014 Markus FriedlAIDArunrun042100k09.01.2014 16:35:4309.01.2014 18:02:17GoodHV=40V  I=3.4uA
centered position, HV scan
5GeV beam, 6 samples
  
  50   Thu Jan 9 14:47:21 2014 Thomas Bergauercommonposition of DESY Table    UnknownBEAM mode:

    height (z): -346 (initially:
-357)
    horizontal (x): -255 

OFF
  
  49   Thu Jan 9 14:07:31 2014 Markus FriedlAIDArunrun041100k09.01.2014 14:06:3209.01.2014 15:33:13GoodHV=30V  I=3.3uA
centered position, HV scan
5GeV beam, 6 samples
  
  48   Thu Jan 9 12:31:29 2014 Markus FriedlAIDArunrun040100k09.01.2014 12:30:3209.01.2014 13:55:47GoodHV=20V  I=2.9uA
centered position, HV scan
5GeV beam, 6 samples
  
  47   Thu Jan 9 11:04:34 2014 Markus FriedlAIDArunrun039100k09.01.2014 11:02:3609.01.2014 12:28:41GoodHV=10V  I=2.1uA
centered position, HV scan
5GeV beam, 6 samples
  
  46   Thu Jan 9 11:02:14 2014 Markus FriedlAIDAinfo    UnknownCreated bad strip masks for the AIDA config
files
  
  45   Thu Jan 9 10:10:31 2014 Markus FriedlAIDAcalcal0388380009.01.2014 10:09:2709.01.2014 10:38:23GoodHV=100V  I=4.2uA
centered position
5GeV beam, single sample
  
  44   Wed Jan 8 22:19:11 2014 Markus FriedlAIDArunrun0371.2M08.01.2014 22:18:3009.01.2014 10:08:14GoodHV=100V  I=4.4uA
centered position
5GeV beam, single sample
  
  43   Wed Jan 8 17:20:40 2014 Markus FriedlAIDArunrun036320k08.01.2014 17:18:5108.01.2014 22:14:58Unknown HV=100V  I=4.3uA
centered position
5GeV beam
  
  42   Wed Jan 8 14:10:07 2014 Thomas BergauerAIDArunrun03521168108.01.2014 14:01:2508.01.2014 17:03:55Unknown HV=100V  I=4.2uA
position adapted to center beam
 
accidentally
hit reset button on PC which ended this run
  
  41   Wed Jan 8 12:40:30 2014 Thomas BergauerAIDAintcal AIDA Stackcal03483.8k08.01.2014 12:32:2208.01.2014 13:01:30Unknown HV=100V  I=4.5uA
position adapted to center beam
 
  
  40   Tue Jan 7 21:34:41 2014 Markus FriedlInfineonrunrun0334.117.024 (4M)07.01.2014 21:33:1208.01.2014 08:52:37GoodHV=300V  I=8.3uA
position adapted to center beam better
(+10mm horizontal)
  
  39   Tue Jan 7 21:02:58 2014 Markus FriedlInfineonrunrun032200k07.01.2014 21:01:4207.01.2014 21:29:03GoodHV=290V  I=8.3uA
position adapted to center beam better
(+10mm horizontal)
  
  38   Tue Jan 7 20:26:50 2014 Markus FriedlInfineonrunrun031200k07.01.2014 20:25:3207.01.2014 20:58:47GoodHV=280V  I=8.4uA
position adapted to center beam better
(+10mm horizontal)
  
  37   Tue Jan 7 19:44:45 2014 Markus FriedlInfineonrunrun030200k07.01.2014 19:43:3507.01.2014 20:11:03GoodHV=270V  I=8.6uA
position adapted to center beam better
(+10mm horizontal)
  
  36   Tue Jan 7 19:12:07 2014 Markus FriedlInfineonrunrun029200k07.01.2014 19:11:0507.01.2014 19:38:00GoodHV=260V  I=8.7uA
position adapted to center beam better
(+10mm horizontal)
  
  35   Tue Jan 7 18:41:55 2014 Markus FriedlInfineonrunrun028200k07.01.2014 18:40:4007.01.2014 19:07:32GoodHV=250V  I=8.3uA
position adapted to center beam better
(+10mm horizontal)
  
  34   Tue Jan 7 18:11:52 2014 Markus FriedlInfineonrunrun027200k07.01.2014 18:10:4507.01.2014 18:37:42GoodHV=240V  I=8.2uA
position adapted to center beam better
(+10mm horizontal)
  
  33   Tue Jan 7 17:39:20 2014 Markus FriedlInfineonrunrun026200k07.01.2014 17:38:0107.01.2014 18:05:11GoodHV=230V  I=8.2uA
position adapted to center beam better
(+10mm horizontal)
  
  32   Tue Jan 7 17:09:56 2014 Markus FriedlInfineonrunrun025200k07.01.2014 17:08:5407.01.2014 17:36:12GoodHV=220V  I=8.1uA
position adapted to center beam better
(+10mm horizontal)
  
  31   Tue Jan 7 16:36:49 2014 Markus FriedlInfineonrunrun024200k07.01.2014 16:35:4407.01.2014 17:03:10GoodHV=210V  I=8.1uA
position adapted to center beam better
(+10mm horizontal)
  
  30   Tue Jan 7 15:54:22 2014 Markus FriedlInfineonrunrun023200k07.01.2014 15:53:0607.01.2014 16:25:26GoodHV=200V  I=8.0uA
position adapted to center beam better
(+10mm horizontal)
  
  29   Tue Jan 7 15:16:11 2014 Markus FriedlInfineonrunrun022200k07.01.2014 15:15:0907.01.2014 15:42:17GoodHV=150V  I=7.3uA
position adapted to center beam better
(+10mm horizontal)
  
  28   Tue Jan 7 14:51:45 2014 Thomas BergauerBelle SVDTLU control    Unknown1. ssh bastion
2. ssh belle-control
3. ssh 
  
  27   Tue Jan 7 14:47:38 2014 Markus FriedlInfineonrunrun021200k07.01.2014 14:46:0807.01.2014 15:13:23GoodHV=100V  I=7.2uA
position adapted to center beam better
(+10mm horizontal)
  
  26   Tue Jan 7 13:20:48 2014 Markus FriedlInfineonrunrun020300k07.01.2014 13:18:5207.01.2014 14:35:49GoodHV=300V  I=8.5uA
position adapted to center beam better
(+10mm horizontal)
  
  25   Tue Jan 7 11:52:27 2014 Markus FriedlInfineonrunrun019650k07.01.2014 11:47:2407.01.2014 13:15:21GoodHV=300V  I=9.2uA
position adapted to center beam better
(+10mm horizontal)
  
  24   Tue Jan 7 11:50:34 2014 Markus FriedlInfineonscanrun018x10k07.01.2014 11:xx:xx07.01.2014 11:xx:xxGoodDelay scan with single sample
Several runs
  
  23   Tue Jan 7 09:33:51 2014 Thomas Bergauercommonbeam momentum back to 3Gev/crun014 and later ones   Unknown    
  22   Tue Jan 7 09:33:16 2014 Thomas Bergauer runrun017100k07.01.2014 09:31:4507.01.2014 09:52:58GoodHV=300V  I=9.08uA
position
adapted to center beam better (+10mm horizonal)
DESY
table z=-346 x=-255 
  
  21   Tue Jan 7 09:22:09 2014 Thomas Bergauer runrun01650k07.01.2014 09:19:1007.01.2014 09:30:03GoodHV=290V  I=9.00uA
position
move back to original position (0mm/0mm)
(not hitting the right APVs anymore)
DESY
  
  20   Tue Jan 7 09:12:24 2014 Thomas BergauerBelle SVDrunrun01520k07.01.2014 09:10:5207.01.2014 09:15:39Good HV=290V  I=9.55uA
position centered horizontally
(+5mm)
DESY table z=-346 x=-255
 
energy
  
  19   Tue Jan 7 08:36:29 2014 Thomas BergauerInfineonrunrun01420k07.01.2014 08:34:0607.01.2014 09:05:47GoodHV=290V  I=9.55uA
position
centered horizontally (+5mm)
DESY
table z=-346 x=-255 
  
  18   Tue Jan 7 02:18:26 2014 Markus FriedlInfineonrunrun013215k07.01.2014 02:14:5007.01.2014 08:31:25CrapHV=150V  I=7.90uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  17   Tue Jan 7 02:17:14 2014 Thomas Bergauer beam momentum 6GeV/crun013   Unknown    
  15   Tue Jan 7 00:36:03 2014 Markus FriedlInfineonrunrun012190k07.01.2014 00:33:5807.01.2014 02:12:32 GoodHV=150V  I=8.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  14   Mon Jan 6 23:50:59 2014 Markus FriedlInfineonrunrun011200k06.01.2014 23:49:0907.01.2014 00:30:38 GoodHV=280V  I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  13   Mon Jan 6 23:06:51 2014 Markus FriedlInfineonrunrun010200k06.01.2014 23:03:2306.01.2014 23:47:02 GoodHV=270V  I=9.6uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  12   Mon Jan 6 22:23:39 2014 Markus FriedlInfineonrunrun009200k06.01.2014 22:22:1006.01.2014 23:03:23GoodHV=260V  I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  11   Mon Jan 6 21:40:29 2014 Markus FriedlInfineonrunrun008200k06.01.2014 21:38:4606.01.2014 22:20:13GoodHV=210V  I=9.0uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  10   Mon Jan 6 20:57:38 2014 Markus FriedlInfineonrunrun007200k06.01.2014 20:56:0806.01.2014 21:36:54GoodHV=220V  I=9.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  9   Mon Jan 6 20:14:21 2014 Markus FriedlInfineonrunrun006200k06.01.2014 20:12:2006.01.2014 20:54:34GoodHV=240V  I=9.4uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  8   Mon Jan 6 19:31:44 2014 Markus FriedlAIDArunrun005200k06.01.2014 19:29:5206.01.2014 20:09:59GoodHV=230V  I=9.9uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  7   Mon Jan 6 19:10:36 2014 Thomas BergauercommonBeam Momentum 3GeV/crun001 to run012   UnknownWe have set the beam momentum to 3 GeV   IMG_1517.jpgIMG_1516.jpg 
  6   Mon Jan 6 18:49:00 2014 Markus FriedlInfineonrunrun004200k06.01.2014 18:47:3806.01.2014 19:27:33GoodHV=250V  I=9.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  5   Mon Jan 6 18:06:16 2014 Markus FriedlInfineonrunrun003200k06.01.2014 18:04:1406.01.2014 18:44:15GoodHV=200V  I=9.3uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  4   Mon Jan 6 17:17:47 2014 Markus FriedlInfineonrunrun002200k06.01.2014 17:14:3906.01.2014 18:00:34GoodHV=100V  I=8.5uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  3   Mon Jan 6 16:33:13 2014 Markus FriedlInfineonrunrun001200k06.01.2014 16:28:5806.01.2014 17:10:56GoodHV=300V  I=11.1uA
position centered horizontally (+5mm)
DESY table z=-346 x=-255
  
  2   Sun Jan 5 15:08:09 2014 Markus FriedlAIDAcalcal0028380005.01.2014 15:01:3205.01.2014 15:30:36GoodHV=100V  I=6uA   
  1   Sat Jan 4 16:30:46 2014 Markus FriedlInfineoncalcal0018380004.01.2014 16:16:5104.01.2014 16:25:46GoodHV=300V  I=9.3uA  (total)   