Message ID: 76     Entry time: Sat Jan 25 18:46:32 2014
Author: Wolfgang Treberspurg 
Project: Infineon 
Subject: Mulit 6 mode Run Stack 2 
Run Number: HW_Run_Infineon_Stack2_Multi_001 
Events: 340k 
StartTime: 25.01.2014 16:30 
EndTime: 25.01.2014 18:40 
Data: Unknown 

HV 300V, I 10µA

Beam Energy changed during the run between 2GeV - 5GeV - 4GeV

Latency perhaps not optimal set (has been 95) but exchanged trigger cable seems to require 93

ELOG V3.1.5-fc6679b