| ID | 
Date | 
Author | 
Project | 
Subject | 
Run Number  | 
Events | 
StartTime | 
EndTime | 
Data | 
| 
  66  
 | 
Mon Jan 13 01:58:14 2014 | 
Markus Friedl | AIDA | run | run057 | 900k | 13.01.2014  01:56:26 | 13.01.2014  10:48:22 | Good | 
HV=100V  I=3.7uA 
position = 0 / -30 mm relative to initial (but again centered) 
5GeV beam, single sample 
narrow timing (trigger width)  | 
| 
  65  
 | 
Sun Jan 12 18:04:18 2014 | 
Markus Friedl | AIDA | run | run056 | 510k | 12.01.2014  17:59:57 | 13.01.2014  01:47:50 | Good | 
HV=100V  I=3.7uA 
position = -25 / 0 mm relative to initial 
5GeV beam, 6 samples 
narrow timing (trigger width) 
 
Something strange with x/y stage: stuck at approximately y=+3.5 (hitting box lid?), now back to 0, but about 180 strips off compared to run054 (y=0 as well)...  | 
| 
  64  
 | 
Sun Jan 12 10:36:37 2014 | 
Markus Friedl | AIDA | run | run055 | 310913 | 12.01.2014  10:34:44 | 12.01.2014  15:42:47 | Good | 
HV=100V  I=3.6uA 
position = 23 / -35 mm relative to before 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  63  
 | 
Sat Jan 11 22:32:19 2014 | 
Markus Friedl | AIDA | run | run054 | 800k | 11.01.2014  22:30:44 | 12.01.2014  10:13:10 | Good | 
HV=150V  I=5.3uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  62  
 | 
Sat Jan 11 20:56:29 2014 | 
Markus Friedl | AIDA | run | run053 | 100k | 11.01.2014  20:55:29 | 11.01.2014  22:25:43 | Good | 
HV=140V  I=7.1uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  61  
 | 
Fri Jan 10 13:04:49 2014 | 
Markus Friedl | AIDA | run | run052 | 100k | 10.01.2014  13:04:05 | 10.01.2014  14:30:18 | Good | 
HV=130V  I=4.6uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  60  
 | 
Fri Jan 10 11:26:54 2014 | 
Markus Friedl | AIDA | run | run051 | 100k | 10.01.2014  11:26:08 | 10.01.2014  12:53:12 | Good | 
HV=120V  I=4.6uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  58  
 | 
Fri Jan 10 09:54:11 2014 | 
Markus Friedl | AIDA | run | run050 | 100k | 10.01.2014  09:53:13 | 10.01.2014  11:21:12 | Good | 
HV=110V  I=4.1uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  57  
 | 
Fri Jan 10 08:21:46 2014 | 
Markus Friedl | AIDA | run | run049 | 100k | 10.01.2014  08:20:49  | 10.01.2014  09:49:46 | Good | 
HV=100V  I=4.2uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  56  
 | 
Fri Jan 10 00:58:46 2014 | 
Markus Friedl | AIDA | run | run048 | 500k | 10.01.2014  00:57:48 | 10.01.2014  08:17:57 | Good | 
HV=90V  I=3.9uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  55  
 | 
Thu Jan  9 23:27:27 2014 | 
Markus Friedl | AIDA | run | run047 | 100k | 09.01.2014  23:26:35 | 10.01.2014  00:52:56 | Good | 
HV=80V  I=3.8uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  54  
 | 
Thu Jan  9 21:41:20 2014 | 
Markus Friedl | AIDA | run | run046 | 100k | 09.01.2014  21:40:29 | 09.01.2014  23:07:16 | Good | 
HV=70V  I=3.8uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  53  
 | 
Thu Jan  9 19:37:33 2014 | 
Markus Friedl | AIDA | run | run045 | 100k | 09.01.2014  19:36:21 | 09.01.2014  21:01:31  | Good | 
HV=60V  I=3.8uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
  | 
| 
  52  
 | 
Thu Jan  9 18:09:40 2014 | 
Markus Friedl | AIDA | run | run044 | 100k | 09.01.2014  18:08:19 | 09.01.2014  19:35:21 | Good | 
HV=50V  I=3.6uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
MOVED TIMING by 1 clock (now signal is centered again)  | 
| 
  51  
 | 
Thu Jan  9 16:36:30 2014 | 
Markus Friedl | AIDA | run | run042 | 100k | 09.01.2014  16:35:43 | 09.01.2014  18:02:17 | Good | 
HV=40V  I=3.4uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
   | 
| 
  49  
 | 
Thu Jan  9 14:07:31 2014 | 
Markus Friedl | AIDA | run | run041 | 100k | 09.01.2014  14:06:32 | 09.01.2014  15:33:13 | Good | 
HV=30V  I=3.3uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
   | 
| 
  48  
 | 
Thu Jan  9 12:31:29 2014 | 
Markus Friedl | AIDA | run | run040 | 100k | 09.01.2014  12:30:32 | 09.01.2014  13:55:47 | Good | 
HV=20V  I=2.9uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
   | 
| 
  47  
 | 
Thu Jan  9 11:04:34 2014 | 
Markus Friedl | AIDA | run | run039 | 100k | 09.01.2014  11:02:36 | 09.01.2014  12:28:41 | Good | 
HV=10V  I=2.1uA 
centered position, HV scan 
5GeV beam, 6 samples 
narrow timing (trigger width) 
   | 
| 
  44  
 | 
Wed Jan  8 22:19:11 2014 | 
Markus Friedl | AIDA | run | run037 | 1.2M | 08.01.2014  22:18:30 | 09.01.2014  10:08:14 | Good | 
HV=100V  I=4.4uA 
centered position 
5GeV beam, single sample 
narrow timing (trigger width) 
   | 
| 
  43  
 | 
Wed Jan  8 17:20:40 2014 | 
Markus Friedl | AIDA | run | run036 | 320k | 08.01.2014  17:18:51 | 08.01.2014  22:14:58 | Unknown | 
 HV=100V  I=4.3uA 
centered position 
5GeV beam 
narrow timing (trigger width), but 6 samples 
   | 
| 
  42  
 | 
Wed Jan  8 14:10:07 2014 | 
Thomas Bergauer | AIDA | run | run035 | 211681 | 08.01.2014  14:01:25 | 08.01.2014  17:03:55 | Unknown | 
 HV=100V  I=4.2uA 
position adapted to center beam 
  
accidentally hit reset button on PC which ended this run abruptly... 
  
5 GeV beam  | 
| 
  40  
 | 
Tue Jan  7 21:34:41 2014 | 
Markus Friedl | Infineon | run | run033 | 4.117.024 (4M) | 07.01.2014  21:33:12 | 08.01.2014  08:52:37 | Good | 
HV=300V  I=8.3uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV 
  
beam gone at 8:00 morning because of scheduled beam development. last few 100 events only noise.  | 
| 
  39  
 | 
Tue Jan  7 21:02:58 2014 | 
Markus Friedl | Infineon | run | run032 | 200k | 07.01.2014  21:01:42 | 07.01.2014  21:29:03 | Good | 
HV=290V  I=8.3uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  38  
 | 
Tue Jan  7 20:26:50 2014 | 
Markus Friedl | Infineon | run | run031 | 200k | 07.01.2014  20:25:32 | 07.01.2014  20:58:47 | Good | 
HV=280V  I=8.4uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  37  
 | 
Tue Jan  7 19:44:45 2014 | 
Markus Friedl | Infineon | run | run030 | 200k | 07.01.2014  19:43:35 | 07.01.2014  20:11:03 | Good | 
HV=270V  I=8.6uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  36  
 | 
Tue Jan  7 19:12:07 2014 | 
Markus Friedl | Infineon | run | run029 | 200k | 07.01.2014  19:11:05 | 07.01.2014  19:38:00 | Good | 
HV=260V  I=8.7uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  35  
 | 
Tue Jan  7 18:41:55 2014 | 
Markus Friedl | Infineon | run | run028 | 200k | 07.01.2014  18:40:40 | 07.01.2014  19:07:32 | Good | 
HV=250V  I=8.3uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  34  
 | 
Tue Jan  7 18:11:52 2014 | 
Markus Friedl | Infineon | run | run027 | 200k | 07.01.2014  18:10:45 | 07.01.2014  18:37:42 | Good | 
HV=240V  I=8.2uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  33  
 | 
Tue Jan  7 17:39:20 2014 | 
Markus Friedl | Infineon | run | run026 | 200k | 07.01.2014  17:38:01 | 07.01.2014  18:05:11 | Good | 
HV=230V  I=8.2uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  32  
 | 
Tue Jan  7 17:09:56 2014 | 
Markus Friedl | Infineon | run | run025 | 200k | 07.01.2014  17:08:54 | 07.01.2014  17:36:12 | Good | 
HV=220V  I=8.1uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  31  
 | 
Tue Jan  7 16:36:49 2014 | 
Markus Friedl | Infineon | run | run024 | 200k | 07.01.2014  16:35:44 | 07.01.2014  17:03:10 | Good | 
HV=210V  I=8.1uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  30  
 | 
Tue Jan  7 15:54:22 2014 | 
Markus Friedl | Infineon | run | run023 | 200k | 07.01.2014  15:53:06 | 07.01.2014  16:25:26 | Good | 
HV=200V  I=8.0uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  29  
 | 
Tue Jan  7 15:16:11 2014 | 
Markus Friedl | Infineon | run | run022 | 200k | 07.01.2014  15:15:09 | 07.01.2014  15:42:17 | Good | 
HV=150V  I=7.3uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  27  
 | 
Tue Jan  7 14:47:38 2014 | 
Markus Friedl | Infineon | run | run021 | 200k | 07.01.2014  14:46:08 | 07.01.2014  15:13:23 | Good | 
HV=100V  I=7.2uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single trigger 
 
  
Beam energy = 3 GeV  | 
| 
  26  
 | 
Tue Jan  7 13:20:48 2014 | 
Markus Friedl | Infineon | run | run020 | 300k | 07.01.2014  13:18:52 | 07.01.2014  14:35:49 | Good | 
HV=300V  I=8.5uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
multi6 with same settings as run019 (htr+3) 
 
Beam energy = 3 GeV  | 
| 
  25  
 | 
Tue Jan  7 11:52:27 2014 | 
Markus Friedl | Infineon | run | run019 | 650k | 07.01.2014  11:47:24 | 07.01.2014  13:15:21 | Good | 
HV=300V  I=9.2uA 
position adapted to center beam better (+10mm horizontal) 
narrow trigger width (~5ns) 
single sample run 
Beam energy = 3 GeV  | 
| 
  24  
 | 
Tue Jan  7 11:50:34 2014 | 
Markus Friedl | Infineon | scan | run018x | 10k | 07.01.2014 11:xx:xx | 07.01.2014 11:xx:xx | Good | 
Delay scan with single sample 
Several runs  | 
| 
  22  
 | 
Tue Jan  7 09:33:16 2014 | 
Thomas Bergauer |   | run | run017 | 100k | 07.01.2014  09:31:45 | 07.01.2014  09:52:58 | Good | 
HV=300V  I=9.08uA 
position adapted to center beam better (+10mm horizonal) 
DESY table z=-346 x=-255  
3Gev/c  | 
| 
  21  
 | 
Tue Jan  7 09:22:09 2014 | 
Thomas Bergauer |   | run | run016 | 50k | 07.01.2014  09:19:10 | 07.01.2014  09:30:03 | Good | 
HV=290V  I=9.00uA 
position move back to original position (0mm/0mm) (not hitting the right APVs anymore) 
DESY table z=-346 x=-255   | 
| 
  20  
 | 
Tue Jan  7 09:12:24 2014 | 
Thomas Bergauer | Belle SVD | run | run015 | 20k | 07.01.2014  09:10:52 | 07.01.2014  09:15:39 | Good | 
 HV=290V  I=9.55uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
energy switched back to 3Gev/c  | 
| 
  23  
 | 
Tue Jan  7 09:33:51 2014 | 
Thomas Bergauer | common | beam momentum back to 3Gev/c | run014 and later ones |   |   |   | Unknown | 
 | 
| 
  19  
 | 
Tue Jan  7 08:36:29 2014 | 
Thomas Bergauer | Infineon | run | run014 | 20k | 07.01.2014  08:34:06 | 07.01.2014  09:05:47 | Good | 
HV=290V  I=9.55uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255  
6Gev/c,
bad strip region hardly hit  | 
| 
  17  
 | 
Tue Jan  7 02:17:14 2014 | 
Thomas Bergauer |   | beam momentum 6GeV/c | run013 |   |   |   | Unknown | 
 | 
| 
  18  
 | 
Tue Jan  7 02:18:26 2014 | 
Markus Friedl | Infineon | run | run013 | 215k | 07.01.2014  02:14:50 | 07.01.2014  08:31:25 | Crap | 
HV=150V  I=7.90uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum 
  
close to end: switched to 6GeV
bias voltage accidentally left at 150V instead of initially planned 290V | 
| 
  15  
 | 
Tue Jan  7 00:36:03 2014 | 
Markus Friedl | Infineon | run | run012 | 190k | 07.01.2014  00:33:58 | 07.01.2014  02:12:32  | Good | 
HV=150V  I=8.0uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum 
  
close to end: switched to 6GeV  | 
| 
  14  
 | 
Mon Jan  6 23:50:59 2014 | 
Markus Friedl | Infineon | run | run011 | 200k | 06.01.2014  23:49:09 | 07.01.2014  00:30:38  | Good | 
HV=280V  I=9.6uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  13  
 | 
Mon Jan  6 23:06:51 2014 | 
Markus Friedl | Infineon | run | run010 | 200k | 06.01.2014  23:03:23 | 06.01.2014  23:47:02  | Good | 
HV=270V  I=9.6uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  12  
 | 
Mon Jan  6 22:23:39 2014 | 
Markus Friedl | Infineon | run | run009 | 200k | 06.01.2014  22:22:10 | 06.01.2014  23:03:23 | Good | 
HV=260V  I=9.3uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  11  
 | 
Mon Jan  6 21:40:29 2014 | 
Markus Friedl | Infineon | run | run008 | 200k | 06.01.2014  21:38:46 | 06.01.2014  22:20:13 | Good | 
HV=210V  I=9.0uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  10  
 | 
Mon Jan  6 20:57:38 2014 | 
Markus Friedl | Infineon | run | run007 | 200k | 06.01.2014  20:56:08 | 06.01.2014  21:36:54 | Good | 
HV=220V  I=9.1uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  9  
 | 
Mon Jan  6 20:14:21 2014 | 
Markus Friedl | Infineon | run | run006 | 200k | 06.01.2014  20:12:20 | 06.01.2014  20:54:34 | Good | 
HV=240V  I=9.4uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  8  
 | 
Mon Jan  6 19:31:44 2014 | 
Markus Friedl | AIDA | run | run005 | 200k | 06.01.2014  19:29:52 | 06.01.2014  20:09:59 | Good | 
HV=230V  I=9.9uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  6  
 | 
Mon Jan  6 18:49:00 2014 | 
Markus Friedl | Infineon | run | run004 | 200k | 06.01.2014  18:47:38 | 06.01.2014  19:27:33 | Good | 
HV=250V  I=9.5uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  5  
 | 
Mon Jan  6 18:06:16 2014 | 
Markus Friedl | Infineon | run | run003 | 200k | 06.01.2014  18:04:14 | 06.01.2014  18:44:15 | Good | 
HV=200V  I=9.3uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  4  
 | 
Mon Jan  6 17:17:47 2014 | 
Markus Friedl | Infineon | run | run002 | 200k | 06.01.2014  17:14:39 | 06.01.2014  18:00:34 | Good | 
HV=100V  I=8.5uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  7  
 | 
Mon Jan  6 19:10:36 2014 | 
Thomas Bergauer | common | Beam Momentum 3GeV/c | run001 to run012 |   |   |   | Unknown | 
We have set the beam momentum to 3 GeV   | 
| Attachment 1: IMG_1517.jpg
 | 
  | 
| Attachment 2: IMG_1516.jpg
 | 
  | 
| 
  3  
 | 
Mon Jan  6 16:33:13 2014 | 
Markus Friedl | Infineon | run | run001 | 200k | 06.01.2014  16:28:58 | 06.01.2014  17:10:56 | Good | 
HV=300V  I=11.1uA 
position centered horizontally (+5mm) 
DESY table z=-346 x=-255 
  
3 GeV beam momentum  | 
| 
  45  
 | 
Thu Jan  9 10:10:31 2014 | 
Markus Friedl | AIDA | cal | cal038 | 83800 | 09.01.2014  10:09:27 | 09.01.2014  10:38:23 | Good | 
HV=100V  I=4.2uA 
centered position 
5GeV beam, single sample 
narrow timing (trigger width)  | 
| 
  41  
 | 
Wed Jan  8 12:40:30 2014 | 
Thomas Bergauer | AIDA | intcal AIDA Stack | cal034 | 83.8k | 08.01.2014  12:32:22 | 08.01.2014  13:01:30 | Unknown | 
 HV=100V  I=4.5uA 
position adapted to center beam 
   | 
| 
  2  
 | 
Sun Jan  5 15:08:09 2014 | 
Markus Friedl | AIDA | cal | cal002 | 83800 | 05.01.2014  15:01:32 | 05.01.2014  15:30:36 | Good | 
HV=100V  I=6uA  | 
| 
  1  
 | 
Sat Jan  4 16:30:46 2014 | 
Markus Friedl | Infineon | cal | cal001 | 83800 | 04.01.2014  16:16:51 | 04.01.2014  16:25:46 | Good | 
HV=300V  I=9.3uA  (total)  | 
| 
  98  
 | 
Wed Jan 29 22:40:09 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos2_002 | 200k | 29.01.2014 22:40 | 29.01.2014 23:15 | Good | 
HV at 300V; I at app. 7.5µA 3GeV, Single mode 
Position changed to --8.91097 -22.80061 
   | 
| 
  97  
 | 
Wed Jan 29 22:36:35 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_pos1_001 | 200k | 29.01.2014 22:15 | 29.01.2014 22:35 | Good | 
HV at 300V; I at app. 7.5µA 3GeV, Single mode 
Position changed to -3.910970 -17.800610 
   | 
| 
  77  
 | 
Sat Jan 25 21:14:46 2014 | 
Wolfgang Treberspurg | Infineon | Mulit 6 mode Run Stack 2 | HW_Run_Infineon_Stack2_Multi_002 | 230k | 25.01.2014 19:00 | 25.01.2014 21:15 | Good | 
HV 300V, I 10µA 
Beam Energy  4GeV 
Latency changed to 93  | 
| 
  76  
 | 
Sat Jan 25 18:46:32 2014 | 
Wolfgang Treberspurg | Infineon | Mulit 6 mode Run Stack 2 | HW_Run_Infineon_Stack2_Multi_001 | 340k | 25.01.2014 16:30 | 25.01.2014 18:40 | Unknown | 
HV 300V, I 10µA 
Beam Energy changed during the run between 2GeV - 5GeV - 4GeV 
Latency perhaps not optimal set (has been 95) but exchanged trigger cable seems to require 93  | 
| 
  95  
 | 
Wed Jan 29 22:06:12 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_015 | 200k | 29.01.2014 19:15 | 29.01.2014 19:45 | Good | 
HV at 300V; I at app. 7.5µA 3GeV, Single mode 
   | 
| 
  94  
 | 
Wed Jan 29 22:03:15 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_014 | 200k | 29.01.2014 18:15 | 29.01.2014 18:45 | Good | 
HV at 260V; I at app. 7.5µA 3GeV, Single mode 
   | 
| 
  93  
 | 
Wed Jan 29 22:02:04 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_013 | 200k | 29.01.2014 15:26 | 29.01.2014 17:00 | Good | 
HV at 290V; I at app. 8µA 3GeV, Single mode 
   | 
| 
  92  
 | 
Wed Jan 29 22:01:08 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_012 | 200k | 29.01.2014 14:25 | 29.01.2014 15:26 | Good | 
HV at 280V; I at app. 8µA 3GeV, Single mode 
   | 
| 
  91  
 | 
Wed Jan 29 21:59:51 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_011 | 200k | 29.01.2014 13:45 | 29.01.2014 14:20 | Good | 
HV at 270V; I at app. 7.6µA 3GeV, Single mode 
   | 
| 
  90  
 | 
Wed Jan 29 21:57:55 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_010 | 100k | 29.01.2014 13:20 | 29.01.2014 13:35 | Good | 
HV at 260V; I at app. 7.6µA 3GeV, Single mode 
   | 
| 
  89  
 | 
Wed Jan 29 21:56:58 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_009 | 110k | 29.01.2014 12:50 | 29.01.2014 13:15 | Good | 
HV at 250V; I at app. 7.5µA 3GeV, Single mode 
   | 
| 
  88  
 | 
Wed Jan 29 21:56:15 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_008 | 200k | 29.01.2014 12:15 | 29.01.2014 12:45 | Good | 
HV at 240V; I at app. 7.5µA 3GeV, Single mode 
   | 
| 
  87  
 | 
Wed Jan 29 21:55:09 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_007 | 200k | 29.01.2014 11:50 | 29.01.2014 12:15 | Good | 
HV at 230V; I at app. 8µA 3GeV, Single mode 
   | 
| 
  86  
 | 
Wed Jan 29 12:11:00 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_006 | 200k | 28.01.2014 20:30 | 28.01.2014 21:00 | Good | 
HV at 220V; I at app. 8.5µA 3GeV, Single mode 
   | 
| 
  85  
 | 
Wed Jan 29 12:10:06 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_005 | 200k | 28.01.2014 20:00 | 28.01.2014 23:00 | Good | 
HV at 210V; I at app. 8.5µA 3GeV, Single mode 
   | 
| 
  84  
 | 
Wed Jan 29 12:08:52 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_004 | 200k | 28.01.2014 19:30 | 28.01.2014 20:00 | Good | 
HV at 200V; I at app. 9.5µA 3GeV, Single mode 
   | 
| 
  83  
 | 
Wed Jan 29 12:07:48 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_003 | 200k | 28.01.2014 17:40 | 28.01.2014 18:20 | Good | 
HV at 150V; I at app. 9µA 3GeV, Single mode 
   | 
| 
  82  
 | 
Wed Jan 29 12:04:53 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_002 | 140k | 28.01.2014 16:50 | 28.01.2014 17:20 | Good | 
HV at 100V; I at app. 8.5µA 3GeV, Single mode 
   | 
| 
  81  
 | 
Wed Jan 29 12:02:52 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan | HW_Run_Infineon_Stack2_BiasScan_001 | 100k | 28.01.2014 16:30 | 28.01.2014 16:50 | Good | 
HV at 0V; I at app. 5nA 3GeV, Single mode 
   | 
| 
  80  
 | 
Mon Jan 27 12:20:53 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 | HW_Run_Infineon_Stack2_004 | 800k | 27.01.2014 09:10 | 27.01.2014 12:15 | Good | 
HV at 300V; I at app. 10µA 3GeV, Single mode 
   | 
| 
  79  
 | 
Sun Jan 26 19:14:07 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 | HW_Run_Infineon_Stack2_003 | 140 k | 26.01.2014 18:10 | 26.01.2014 19:15 | Good | 
HV at 300V; I at app. 10µA 5GeV, Single mode 
   | 
| 
  78  
 | 
Sun Jan 26 19:12:42 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 | HW_Run_Infineon_Stack2_002 | 4 M | 25.01.2014 22:30 | 26.01.2014 15:15 | Good | 
HV at 300V; I at app. 11µA 4GeV, Single mode 
   | 
| 
  74  
 | 
Sat Jan 25 18:24:03 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 | HW_Run_Infineon_Stack2_001 | 1.05 M | 25.01.2014 10:30 | 25.01.2014 15:40 | Unknown | 
HV at 300V; I at app. 11µA 4GeV, Single mode 
Modules centered to beam but no hits at additional Strixel modul. Perhaps HV problems (High noise of Strixel almost did not change after biasing) 
-> HV connection will be checked at next opportunity to enter area.  | 
| 
  72  
 | 
Fri Jan 24 11:23:15 2014 | 
Hao Yin |   | AIDA | HW_AIDA003 | 76356 | 24.02.2014 10:30 | 24.02.2014 11:22 | Unknown | 
HV=100V  I=3.7uA 
position = 0 / -30 mm relative to initial (but again centered) no idea --- 
3GeV beam, multipeak 6 samples 
???narrow timing (trigger width)??? no idea ...  | 
| 
  71  
 | 
Fri Jan 24 11:03:14 2014 | 
Wolfgang Treberspurg | AIDA | AIDA | HW_AIDA002 | 0 | 24.01.2014 10:02 |   | Crap | 
TuxDaq crashed  | 
| 
  70  
 | 
Fri Jan 24 00:21:16 2014 | 
Hao Yin |   | AIDA | HW_AIDA001 | 40k | 24.02.2014 00:18 |   | Unknown | 
HV=100V  I=3.7uA 
position = 0 / -30 mm relative to initial (but again centered) no idea --- 
3GeV beam, multipeak 6 samples 
???narrow timing (trigger width)??? no idea ...  | 
| 
  75  
 | 
Sat Jan 25 18:28:38 2014 | 
Wolfgang Treberspurg | Infineon | Calibration run Infineon Stack 2 | Calibration_Run_Infineon_Stack2_001 | 82900 | 25.01.2014 10:15 | 25.01.2014 10:25 | Unknown | 
HV 300V, I ca. 11µA single mode  | 
| 
  69  
 | 
Thu Jan 23 22:47:49 2014 | 
Hao Yin |   | AIDA | CalibrationRun001 | 83800 | 23.01.2014 13:35:55 | 23.01.2014 02:08:15 | Good | 
taken with tuxdaq... 
HV=75V  I=?3.7uA? 
position = 0 / -30 mm relative to initial (but again centered) ? 
?5GeV beam, single sample? (software trigger run) 
?narrow timing (trigger width)?  | 
| 
  28  
 | 
Tue Jan  7 14:51:45 2014 | 
Thomas Bergauer | Belle SVD | TLU control |   |   |   |   | Unknown | 
1. ssh bastion 
2. ssh belle-control 
3. ssh telescope-admin@tb-aconite 
(password telescope++) 
dann: 
How to generate trigger from TLU through FTSW to detector systems 
2014.1.6 Mikihiko Nakao 
 
* step 1 - open monitor window to show the FTSW status 
 
 [you@bastion03 ~]$ ssh telescope-admin@belle-rpc1 
  (still only limited people has access to b2daq account: 
   ask DAQ people or Katsuro Nakamura of SVD group) 
 
 [b2daq@belle-rpc1 ~]$ ssh telescope-admin@ttd10 
 [b2daq@ttd10 ~]$ statft -55 -i -c 
   (55 is the FTSW board-id, -i -c are to show the status repeatedly) 
 
* step 2 - initialize FTSW to accept TLU trigger 
 
 [b2daq@ttd10 ~]$ trigft -55 tlu 
 
* step 3 - start trigger at TLU 
 
 [you@bastion03 ~]$ ssh belle-rpc2 
 [you@belle-rpc2 ~]$ ssh telescope-admin@tb-aconite 
  (ask Alan Campbell or somebody for the password) 
 
 telescope-admin@tb-aconite:~$ cd eudaq-nakao/bin 
 ...$ ./TLUControl.exe -a 4 -d 1 -i RJ45 -w 10 -n 
 
 here, -a option gives the possible trigger coincidence 
  (-a 1  --- dummy trigger generator from FTSW) 
   -a 2  --- trigger counter 1 only 
   -a 4  --- trigger counter 2 only 
   -a 8  --- trigger counter 3 only 
   -a 6  --- trigger counter 1 and 2 
   -a 10 --- trigger counter 1 and 3 
   -a 12 --- trigger counter 2 and 2 
   -a 14 --- trigger counter 1 and 2 and 3 
 other options are kept to be the same 
   -d 1 -i RJ45 --- connection to FTSW 
   -w 10        --- update frequency (10msec) 
   -n           --- suppress messages 
 
 This gives you output like: 
 
   Status:    00,--,--,--,--,-- (0,0) 
   Scalers:   0, 7, 0, 0    <== from FTSW-dummy and trigger counters 1, 2, 3 
   Particles: 1 
   Triggers:  0             <== actual trigger to be distributed to FTSW 
   Entries:   0 
   TS errors: 0, 0 (redundancy, re-read) 
   Timestamp: 0x4f25a008 (1327865864) = 3.45791 
   Time: 3.463 s, Freq: 0 Hz, Average: 0 Hz 
 
 
-   | 
| 
  46  
 | 
Thu Jan  9 11:02:14 2014 | 
Markus Friedl | AIDA | info |   |   |   |   | Unknown | 
Created bad strip masks for the AIDA config files  | 
| 
  50  
 | 
Thu Jan  9 14:47:21 2014 | 
Thomas Bergauer | common | position of DESY Table |   |   |   |   | Unknown | 
BEAM mode: 
    - height (z): -346 (initially: -357)
 
    - horizontal (x): -255 
 
 
OFF BEAM mode (Parkposition): 
    - height (z): +37
 
    - horizontal (x): -255 
 
 
   | 
| 
  59  
 | 
Fri Jan 10 11:02:31 2014 | 
Markus Friedl | Belle SVD | Power supply |   |   | 10.01.2014  11:00:00 |   | Unknown | 
 | 
| Attachment 1: KenWood100114.png
 | 
  | 
| 
  67  
 | 
Mon Jan 13 12:02:40 2014 | 
Markus Friedl | common | Kontakt |   |   |   |   | Unknown | 
Richard Thalmeier   Tel. 4801 
Hao Yin     | 
| 
  68  
 | 
Sun Jan 19 18:01:46 2014 | 
Christian Irmler | common | AIDA setup operated with TuxDAQ |   |   |   |   | Unknown | 
New SIS driver version sis1100-2.13-3 installed on DAQPC.  
To install the driver call as root: 
cd /lib/modules/2.6.18-371.3.1.el5/extra 
/sbin/modprobe sis1100 
Check if /dev/sis* are created. 
Managed to run the AIDA setup with old TuxDAQ version from T. Obermayer. 
Will now try to install a newer version, which also supports ADC delay scan and internal calibration.  | 
| 
  73  
 | 
Fri Jan 24 18:02:46 2014 | 
Wolfgang Treberspurg | Infineon | New Infineon Stack |   |   |   |   | Good | 
Exchanged AIDA stack with modified Infineon Stack  
Configuration:  
Beam   Infineon_TB_2014_Baby1(P0)   ---   Inifineon_TB_2014_Baby2(P1) |||  Infineon_TB_2012_Baby2(P2)  --- Infineon_TB_2012_Baby1(P3) ||| Infineon_TB_2012_Strixel_Top-left(N0)  --- Infineon_TB_2012_Strixel_Bottom-right(N1) ---   | 
| 
  96  
 | 
Wed Jan 29 22:08:48 2014 | 
Wolfgang Treberspurg | Infineon | Single mode Run Stack 2 Bias Scan |   |   | 29.01.2014 22:00 | 29.01.2014 22:00 | Good | 
All Infineon Stack 2 runs have been taken at table position: 1.089030, -12.800610 
   |