  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 5 of 7  Not logged in ELOG logo
Entry  Tue Oct 17 15:13:42 2017, Dominic Bloech, IFX_CenterBias, run000081, 81, 1010000, 122.9, 26, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000081.dat
Telescope filename  run000081.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

Entry  Wed Oct 18 11:48:51 2017, Peter Paulitsch, IFX_CenterBias, run000085, 85, 1010000, 122.9, 26, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000085.dat
Telescope filename  run000085.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

Entry  Wed Oct 18 11:59:30 2017, Peter Paulitsch, IFX_CenterBias, run000088, 88, 1010000, 122.9, 31, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000088.dat
Telescope filename  run000088.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 31
Region of interest upper part
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 45.4%

 

Entry  Wed Oct 18 12:12:55 2017, Peter Paulitsch, IFX_CenterBias, run000091, 91, 1010000, 122.9, 21, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000091.dat
Telescope filename  run000091.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 21
Region of interest lower part
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.7%

 

Entry  Wed Oct 18 12:19:14 2017, Peter Paulitsch, IFX_CenterBias, run000093, 93, 1010000, 122.9, 26, -3.3°, No, Good 
run settings
Parameter Value
Alibava filename  run000093.dat
Telescope filename  run000093.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

Entry  Fri Oct 20 14:35:48 2017, Peter Paulitsch, IFX_200_3e14, run000177, 177, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000177.dat
Telescope filename  run000177.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -400 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

Entry  Fri Oct 20 15:30:18 2017, Peter Paulitsch, IFX_200_3e14, run000206, 206, 1010000, 75.93, 65.30, -90.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000206.dat
Telescope filename  run000206.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Fri Oct 20 15:33:44 2017, Peter Paulitsch, IFX_200_3e14, run000210, 210, 1010000, 75.93, 65.30, -80.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000210.dat
Telescope filename  run000210.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.9%

 

Entry  Fri Oct 20 15:41:56 2017, Peter Paulitsch, IFX_200_3e14, run000219, 219, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000219.dat
Telescope filename  run000219.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

Entry  Mon Oct 23 09:24:23 2017, Dominic Bloech, HPK_3e14, run000240, 240, 1010000, 75.93, 65.30, -70.55°, Yes, Crap 
Parameter Value
Alibava filename  run000240.dat
Telescope filename  run000240.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -100 V
Dark current  
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  200
Meas. time 80min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
Entry  Mon Oct 23 12:10:15 2017, Peter Paulitsch, IFX_200_3e14, run000175, 175, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
run settings
Parameter Value
Alibava filename  run000177.dat
Telescope filename  run000177.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

Entry  Tue Oct 24 17:50:04 2017, Peter Paulitsch, HPK_3e14, run000242, 242, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000242.dat
Telescope filename  run000242.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 29.7%
Entry  Tue Oct 24 17:51:18 2017, Peter Paulitsch, HPK_3e14, run000246, 246, 1010000, 75.93, 65.30, -100.55°, Yes, Good 
Parameter Value
Alibava filename  run000246.dat
Telescope filename  run000246.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:56:36 2017, Peter Paulitsch, HPK_3e14, run000249, 249, 1010000, 75.93, 65.30, -90.55°, Yes, Good 
Parameter Value
Alibava filename  run000249.dat
Telescope filename  run000249.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 17:58:43 2017, Peter Paulitsch, HPK_3e14, run000257, 257, 1010000, 75.93, 65.30, -80.55°, Yes, Good 
Parameter Value
Alibava filename  run000257.dat
Telescope filename  run000257.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:01:13 2017, Peter Paulitsch, HPK_3e14, run000261, 261, 1010000, 75.93, 65.30, -70.55°, Yes, Good 
Parameter Value
Alibava filename  run000261.dat
Telescope filename  run000261.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
Entry  Tue Oct 24 18:08:57 2017, Peter Paulitsch, HPK_200, run000275, 275, 1010000, 0°, No, Good 
Parameter Value
Alibava filename  run000275.dat
Telescope filename  run000275.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
Entry  Tue Oct 24 18:09:24 2017, Peter Paulitsch, HPK_200, run000277, 277, 1010000, 0°, No, Good 
Parameter Value
Alibava filename  run000277.dat
Telescope filename  run000277.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
Entry  Tue Oct 24 18:10:39 2017, Peter Paulitsch, HPK_200, run000283, 283, 1010000, 0°, No, Good 
Parameter Value
Alibava filename  run000283.dat
Telescope filename  run000283.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
Entry  Tue Oct 24 18:11:13 2017, Peter Paulitsch, HPK_200, run000285, 285, 1010000, 0°, No, Good 
Parameter Value
Alibava filename  run000285.dat
Telescope filename  run000285.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  