Home
CMS Production
Clean room
MedAustron
HEPHY
testbeams
old
testbeam-rd50-desy-Oct2024
testbeam-RD50-DESY-Apr2024
testbeam-RD50-DESY-Jul2023
testbeam-RD50-CERN-Oct2022
testbeam-DESY-Oct2017
testbeam-DESY-April2017
testbeam-SPS2015
testbeam-SPS2014
testbeam-DESY14
testbeam-SPS12
testbeam-SPS11
testbeam-SPS10
testbeam-SPS09
testbeam-SPS08
LP-TPC
Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter)
Not logged in
List
|
Find
|
Login
|
Help
Message ID:
60
Entry time:
Mon Oct 23 09:24:23 2017
Author:
Dominic Bloech
DUT:
HPK_3e14
Subject:
run000240
Run Number:
240
Events:
1010000
XYPosition:
75.93, 65.30, -70.55°
Cooling:
Yes
Data:
Crap
Parameter
Value
Alibava filename
run000240.dat
Telescope filename
run000240.raw
Pedestal filename
KIT_pedestal_600V_20102017.ped
Bias voltage
-100 V
Dark current
Sensor temperature
-6
Latency
140 [a.u.]
Alibava triggers
3010000
Telescope triggers
3000000
Data synced
yes
Table position x/y
75.93, 65.30
Region of interest
bias line
Trigger frequency
200
Meas. time
80min
Beam energy
5.6 GeV
Cooling
yes
Alibava efficiency
29.7%
ELOG V3.1.5-fc6679b