ID |
Date |
Author |
Project |
Subject |
Run Number |
Events |
XYPosition |
Cooling |
Data |
129
|
Wed Apr 19 20:55:36 2017 |
Axel Koenig | ALiBaVa (IFX) | run_003_Irrad_300V.dat | 003 | 300000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 632. Bias scan -300V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_003_Irrad_300V.dat |
Telescope run |
632 |
Triggers |
300000 |
Alibava trigger eff. |
~70% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-300 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
35.1 uA |
|
4
|
Wed Apr 12 22:34:18 2017 |
Axel König | ALiBaVa (IFX) | run_002_IFX_CB_100V.dat | 002 | 100000 | 109, 0.5, 240 | No | Unknown |
Remarks: Beam position on only one chip.
Parameter |
Value |
Alibava run |
run_002_IFX_CB_100V.dat |
Telescope run |
498 |
triggers |
100000 |
Alibava trigger eff. |
? |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 V |
Latency |
132 |
Table x |
109 mm |
Table z |
0.5 mm |
Table rot |
240 deg (parallel to tele. planes) |
|
77
|
Sat Apr 15 17:38:58 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_Baby_100V.dat | 002 | 250000 | 102.5, 12.5, 240 | No | Unknown |
Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_Baby_100V.dat |
Telescope run |
563 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
12.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
106
|
Mon Apr 17 16:36:56 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_HPK_CB_200V.dat | 002 | 450000 | 107, 5.8, 240 | No | Unknown |
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_002_HPK_CB_200V.dat |
Telescope run |
605 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
5.8 mm |
Tabe rot |
240 deg
|
|
124
|
Tue Apr 18 18:48:27 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_double_irrad_100V.dat | 002 | 700000 | 94, 1, 240 | No | Unknown |
Remarks: Telescope run 623. 1nd chip only. Central position.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_002_double_irrad_100V.dat |
Telescope run |
623 |
Triggers |
700000 |
Alibava trigger eff. |
~62% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
94 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
128
|
Wed Apr 19 19:27:38 2017 |
Axel Koenig | ALiBaVa (IFX) | run_002_Irrad_200V.dat | 002 | 400000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 630. Bias scan -200V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_002_Irrad_200V.dat |
Telescope run |
630 |
Triggers |
400000 |
Alibava trigger eff. |
~65% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
29.7 uA |
|
1
|
Wed Apr 12 21:06:44 2017 |
Axel König | ALiBaVa (IFX) | run_001_IFX_CB_100V.dat | 001 | 200000 | 109, 4.5, 240 | No | Unknown |
First run for alibava modules with Sensor IFX_CB.
Beam energy = 5.6 GeV
Telescope threshold = 6
Telescope data file = 496
Bias voltage = -100V
Telescope synchornisation: yes
Position table (is center of sensor):
x=109mm
y=4.5mm
phi=240 deg
|
9
|
Thu Apr 13 10:03:29 2017 |
Axel König | ALiBaVa (IFX) | run_001_IFX_CB_100V.dat | 001 | 200000 | 109, 4.5, 240 | No | Unknown |
Remarks: Telescope run 496. Bias voltage 100 V. First run at DESY TB.
Parameter |
Value |
Alibava run |
run_001_IFX_CB_100V.dat |
Telescope run |
496 |
Triggers |
200000 |
Alibava trigger eff. |
? |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
109 mm |
Table z |
4.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
75
|
Sat Apr 15 16:52:06 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_Baby_100V.dat | 001 | 250000 | 102.5, 22.5, 240 | No | Unknown |
Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).
Position: 102.5, 22.5, 240 (should be the center of the sensor).
Parameter |
Value |
Alibava run |
run_001_Baby_100V.dat |
Telescope run |
562 |
Triggers |
250000 |
Alibava trigger eff. |
~93% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
102.5 mm |
Table z |
22.5 mm |
Tabe rot |
240 deg (parallel to tele. planes)
|
|
105
|
Mon Apr 17 13:30:01 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_HPK_CB_200V.dat | 001 | 450000 | 107, 0, 240 | No | Unknown |
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.
Telescope chiller turned off (could be the root cause of runs crashing).
Parameter |
Value |
Alibava run |
run_001_HPK_CB_200V.dat |
Telescope run |
604 |
Triggers |
450000 |
Alibava trigger eff. |
~64% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-200 |
Latency |
132 |
Table x |
107 mm |
Table z |
0 mm |
Tabe rot |
240 deg
|
|
123
|
Tue Apr 18 18:19:33 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_double_irrad_100V.dat | 001 | 350000 | 111, 1, 240 | No | Unknown |
Remarks: Telescope run 620. 2nd chip only. Central position.
Telescope chiller turned on!
Parameter |
Value |
Alibava run |
run_001_double_irrad_100V.dat |
Telescope run |
620 |
Triggers |
350000 |
Alibava trigger eff. |
~53% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
111 mm |
Table z |
1 mm |
Tabe rot |
240 deg
|
|
127
|
Wed Apr 19 17:31:43 2017 |
Axel Koenig | ALiBaVa (IFX) | run_001_Irrad_100V.dat | 001 | 400000 | 96, 64, 360 | No | Unknown |
Remarks: Telescope run 628. Bias scan -100V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.
Backside Biasing!
Telescope chiller turned on (15 deg).
Parameter |
Value |
Alibava run |
run_001_Irrad_100V.dat |
Telescope run |
628 |
Triggers |
400000 |
Alibava trigger eff. |
~49% |
Beam energy |
5.6 GeV |
Telescope threshold |
6 |
Bias voltage |
-100 |
Latency |
132 |
Table x |
96 mm |
Table z |
64 mm |
Tabe rot |
360 deg
|
Temperature at DUT |
-14.5 +- 1 deg. celsius |
Current |
23.5 uA |
|
2
|
Wed Apr 12 21:55:13 2017 |
Axel König | common | pulse shape | | | | No | Unknown |
pulse shape looks good for latency 132. This value is now taken by default for all runs unless otherwise stated. |
3
|
Wed Apr 12 21:56:48 2017 |
Axel König | common | Kazu beetle settings | | | | No | Unknown |
Beetle setting for a better defined pulse shape. These parameters were found by kazu, a beetle developer at lhcb.
CompCtrl=9
Ibuf=10
Icurrbuf=119
Ipipe=13
Ipre=75
Isf=29
Isha=10
Itp=0
Ivoltbuf=29
Latency=133
ROCtrl=26
RclkDiv=0
Vd=140
Vdcl=107
Vfp=31
Vfs=102 |
67
|
Fri Apr 14 14:21:35 2017 |
Axel Koenig | common | Run summary IFX_CB | | | | No | Unknown |
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
496 |
yes |
position check |
200000 |
none |
002 |
498 |
yes |
beam focused on one strip segment only |
100000 |
none |
003 |
500 |
yes |
beam focused on one strip segment only |
100000 |
none |
005 |
508 |
yes |
Bias scan. Voltage = 10 V |
285000 |
none |
006 |
510 |
yes |
Bias scan. Voltage = 20 V |
185000 |
none |
007 |
513 |
yes |
Bias scan. Voltage = 30 V |
170000 |
none |
008 |
515 |
yes |
Bias scan. Voltage = 40 V |
175000 |
none |
009 |
517 |
yes |
Bias scan. Voltage = 50 V |
175000 |
none |
010 |
521 |
yes |
Bias scan. Voltage = 60 V |
175000 |
none |
011 |
522 |
yes |
Bias scan. Voltage = 65 V |
175000 |
none |
012 |
523 |
yes |
Bias scan. Voltage = 70 V |
175000 |
none |
013 |
524 |
yes |
Bias scan. Voltage = 75 V |
175000 |
none |
014 |
525 |
yes |
Bias scan. Voltage = 80 V |
175000 |
none |
015 |
526 |
yes |
Bias scan. Voltage = 90 V |
175000 |
none |
016 |
527-531 |
yes |
Bias scan. Voltage = 100 V |
750000 |
Telescope files 527 to 531, run crashed! |
017 |
532 |
yes |
Bias scan. Voltage = 110 V |
175000 |
none |
018 |
533 |
yes |
Bias scan. Voltage = 120 V |
175000 |
none |
020 |
535 |
yes |
overnight run at 100 V |
190000 |
run crashed data may be corrupted |
021 |
540 |
yes |
CRAP! |
? |
CRAP! |
022 |
545 |
yes |
beam focused on one strip segment only |
500000 |
none |
023 |
546 |
yes |
beam focused on one strip segment only |
385000 |
run crashed data may be corrupted |
024 |
547 |
yes |
Bias scan. Voltage = 140 V |
175000 |
none |
025 |
548 |
yes |
Bias scan. Voltage = 150 V |
175000 |
none |
026 |
549 |
yes |
Rotation -10 deg |
350000 |
none |
027 |
550 |
yes |
Rotation +10 deg |
350000 |
none |
028 |
551 |
yes |
overnight run at 100 V |
3000000 |
run crashed data may be corrupted |
029 |
557 |
yes |
Bias scan. Voltage = 130 V |
175000 |
none |
030 |
558 |
yes |
long run |
1000000 |
telescope chiller turned off (keept at this state unless otherwisde stated |
Central beam position: x = 109 mm, y = 4.5 mm, rot = 240 deg
Current was stable for all runs i.e. 140 +- 10 nA at 100 V
Trigger efficiency ~ 60% for all runs (except bias scan).
Temperature in area 20+-1 deg. |
76
|
Sat Apr 15 16:55:19 2017 |
Axel Koenig | common | Chiller turned off! | | | | No | Unknown |
The chiller has been turned off beginning of run_30_IFX_CB_100V.dat.
Set temperature was 15 C. Now it should settle at 20 +- 1 C (room temperature).
|
98
|
Mon Apr 17 10:14:15 2017 |
Axel Koenig | common | Run summary Baby | | | | No | Unknown |
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
562 |
yes |
first run |
250000 |
none |
002 |
563 |
yes |
central position shifted by -1 cm vertically |
250000 |
none |
003 |
564 |
yes |
central position shifted by + 1cm |
250000 |
none |
004 |
565 |
yes |
central position angle +10 deg |
250000 |
none |
005 |
568 |
yes |
central position angle -10 deg |
250000 |
none |
006 |
570 |
yes |
unknown (maybe long run over night that crashed) |
? |
data may be corrupted |
007 |
579 |
yes |
bias scan -10V |
450000 |
run crashed data only valid up to 274915 |
008 |
583 |
yes |
bias scan -20V |
175000 |
none |
009 |
586 |
yes |
bias scan -30V |
135000 |
none |
010 |
587 |
yes |
bias scan -40V |
135000 |
none |
011 |
588 |
yes |
bias scan -50V |
135000 |
none |
012 |
589 |
yes |
bias scan -60V |
135000 |
none |
013 |
590 |
yes |
bias scan -65V |
112000 |
none |
014 |
591 |
yes |
bias scan -70V |
112000 |
none |
015 |
592 |
yes |
long run over night |
2500000 |
none |
016 |
593 |
yes |
bias scan -75V |
112000 |
none |
017 |
594 |
yes |
bias scan -80V |
112000 |
none |
018 |
595 |
yes |
bias scan -90V |
112000 |
none |
019 |
596 |
yes |
bias scan -110V |
112000 |
none |
020 |
597 |
yes |
bias scan -120V |
112000 |
none |
021 |
598 |
yes |
bias scan -130V |
112000 |
none |
022 |
599 |
yes |
bias scan -140V |
112000 |
none |
023 |
600 |
yes |
bias scan -150V |
112000 |
none |
Central beam position: x = 102 mm, y = 22.5 mm, rot = 240 deg
Current was stable for all runs i.e. 500 +- 10 nA at 100 V
Trigger efficiency ~ 90% for all runs (except bias scan).
Temperature in area 20+-1 deg.
Telescope chiller off for all runs. |
108
|
Mon Apr 17 17:25:24 2017 |
Axel Koenig | common | Telescope geometry ALiBaVa | | | | No | Unknown |
The plane distances are measured at the center of the planes.
The distance of the DUT to the neighbouring planes is measured from the position of the sensor to the center of the planes.
|
Draft
|
Tue Apr 18 17:55:19 2017 |
Axel Koenig | common | Run summary HPK_CB | | | | No | Unknown |
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
562 |
yes |
first run |
250000 |
none |
002 |
563 |
yes |
central position shifted by -1 cm vertically |
250000 |
none |
003 |
564 |
yes |
central position shifted by + 1cm |
250000 |
none |
004 |
565 |
yes |
central position angle +10 deg |
250000 |
none |
005 |
568 |
yes |
central position angle -10 deg |
250000 |
none |
006 |
570 |
yes |
unknown (maybe long run over night that crashed) |
? |
data may be corrupted |
007 |
579 |
yes |
bias scan -10V |
450000 |
run crashed data only valid up to 274915 |
008 |
583 |
yes |
bias scan -20V |
175000 |
none |
009 |
586 |
yes |
bias scan -30V |
135000 |
none |
010 |
587 |
yes |
bias scan -40V |
135000 |
none |
011 |
588 |
yes |
bias scan -50V |
135000 |
none |
012 |
589 |
yes |
bias scan -60V |
135000 |
none |
013 |
590 |
yes |
bias scan -65V |
112000 |
none |
014 |
591 |
yes |
bias scan -70V |
112000 |
none |
015 |
592 |
yes |
long run over night |
2500000 |
none |
016 |
593 |
yes |
bias scan -75V |
112000 |
none |
017 |
594 |
yes |
bias scan -80V |
112000 |
none |
018 |
595 |
yes |
bias scan -90V |
112000 |
none |
019 |
596 |
yes |
bias scan -110V |
112000 |
none |
020 |
597 |
yes |
bias scan -120V |
112000 |
none |
021 |
598 |
yes |
bias scan -130V |
112000 |
none |
022 |
599 |
yes |
bias scan -140V |
112000 |
none |
023 |
600 |
yes |
bias scan -150V |
112000 |
none |
Central beam position: x = 102 mm, y = 22.5 mm, rot = 240 deg
Current was stable of all runs i.e. 500 +- 10 nA at 100 V
Trigger efficiency ~ 90% for all runs (except bias scan).
Temperature in area 20+-1 deg.
Telescope chiller off for all runs. |
122
|
Tue Apr 18 17:56:37 2017 |
Axel Koenig | common | Run summary HPK_CB | | | | No | Unknown |
Alibava run |
Telescope run |
File existence check |
Run type |
Triggers |
Remarks |
001 |
604 |
yes |
first run, only one chip |
450000 |
none |
002 |
605 |
yes |
only one chip |
450000 |
none |
003 |
606 |
yes |
angle scan -10 deg |
250000 |
none |
004 |
607 |
yes |
angle scan +10 deg |
250000 |
none |
005 |
609 |
yes |
Bias scan -50V |
150000 |
none |
006 |
610 |
yes |
Bias scan -100V |
150000 |
none |
007 |
611 |
yes |
Bias scan -150V |
300000 |
none |
008 |
613 |
yes |
Bias scan -250V |
150000 |
none |
009 |
614 |
yes |
Long run over night |
2400000 |
run crashed over night |
010 |
616 |
yes |
repeated long run |
~10000 |
run crashed |
Central beam position: x = 107 mm, y = 2.6 mm, rot = 240 deg
Current was stable for all runs i.e. 80 +- 5 nA at 200 V
Trigger efficiency ~ 65% for all runs (except bias scan).
Temperature in area 20+-1 deg.
Telescope chiller off for all runs. |