Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 6 of 7  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Project Subject Run Number Events XYPositionup Cooling Data
  15   Thu Apr 13 13:07:39 2017 Axel KoenigALiBaVa (IFX)run_010_IFX_CB_60V.dat010175000109, 4.5, 240NoUnknown

Remarks: Telescope run 521. Bias scan 60 V.

Parameter Value
Alibava run run_010_IFX_CB_60V.dat
Telescope run 521
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -60
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  17   Thu Apr 13 15:26:22 2017 Axel KoenigALiBaVa (IFX)run_011_IFX_CB_65V.dat011175000109, 4.5, 240NoUnknown

Remarks: Telescope run 522. Bias scan 65 V.

Parameter Value
Alibava run run_011_IFX_CB_65V.dat
Telescope run 522
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -65
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  18   Thu Apr 13 16:00:25 2017 Axel KoenigALiBaVa (IFX)run_012_IFX_CB_70V.dat012175000109, 4.5, 240NoUnknown

Remarks: Telescope run 523. Bias scan 70 V.

Parameter Value
Alibava run run_012_IFX_CB_70V.dat
Telescope run 523
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -70
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  21   Thu Apr 13 16:33:32 2017 Axel KoenigALiBaVa (IFX)run_013_IFX_CB_75V.dat013175000109, 4.5, 240NoUnknown

Remarks: Telescope run 524. Bias scan 75 V.

Parameter Value
Alibava run run_013_IFX_CB_75V.dat
Telescope run 524
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -75
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  25   Thu Apr 13 17:11:31 2017 Axel KoenigALiBaVa (IFX)run_014_IFX_CB_80V.dat014175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 525. Bias scan 80 V.

Parameter Value
Alibava run run_014_IFX_CB_80V.dat
Telescope run 525
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -80
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  28   Thu Apr 13 17:47:28 2017 Axel KoenigALiBaVa (IFX)run_015_IFX_CB_90V.dat015175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 526. Bias scan 90 V.

Parameter Value
Alibava run run_015_IFX_CB_90V.dat
Telescope run 526
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -90
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  32   Thu Apr 13 18:26:57 2017 Axel KoenigALiBaVa (IFX)run_016_IFX_CB_100V.dat016750000109, 4.5, 240NoCrap

3Remarks: Telescope run 527-531. Bias scan 100 V. Telescope got out of sync. Match with telescope data only up to 175000 events.

Parameter Value
Alibava run run_016_IFX_CB_100V.dat
Telescope run 527-531
Triggers 750000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  33   Thu Apr 13 20:49:30 2017 Axel KoenigALiBaVa (IFX)run_017_IFX_CB_110V.dat017175000109, 4.5, 240NoUnknown

Remarks: Telescope run 532. Bias scan 110 V.

Parameter Value
Alibava run run_017_IFX_CB_110V.dat
Telescope run 532
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -110
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  36   Thu Apr 13 21:23:11 2017 Axel KoenigALiBaVa (IFX)run_018_IFX_CB_120V.dat018175000109, 4.5, 240NoUnknown

Remarks: Telescope run 533. Bias scan 120 V.

Parameter Value
Alibava run run_018_IFX_CB_120V.dat
Telescope run 533
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -120
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  59   Fri Apr 14 08:59:26 2017 Axel KoenigALiBaVa (IFX)run_020_IFX_CB_100V.dat020190000109, 4.5, 240NoCrap

Remarks: Telescope run 535. Bias scan 100 V. Run crashed over night. Telescope sync only up to event 190000 (planned 2500000 events).

Parameter Value
Alibava run run_020_IFX_CB_100V.dat
Telescope run 535
Triggers 190000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  60   Fri Apr 14 09:25:09 2017 Axel KoenigALiBaVa (IFX)run_024_IFX_CB_140V.dat024175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 547. Bias scan 140 V.

Parameter Value
Alibava run run_024_IFX_CB_140V.dat
Telescope run 547
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -140
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  69   Fri Apr 14 17:22:52 2017 Axel KoenigALiBaVa (IFX)run_025_IFX_CB_150V.dat025175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 548. Bias scan 150 V.

Parameter Value
Alibava run run_025_IFX_CB_150V.dat
Telescope run 548
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -150
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  72   Fri Apr 14 21:11:18 2017 Axel KoenigALiBaVa (IFX)run_028_IFX_CB_100V.dat0283000000109, 4.5, 240NoCrap

Remarks: Telescope run 551. Longrun over night. Run crashed. Events only up to 2288000 valid.

Parameter Value
Alibava run run_028_IFX_CB_100V.dat
Telescope run 551
Triggers 3000000
Alibava trigger eff. ~60 %
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg

  73   Sat Apr 15 09:57:51 2017 Axel KoenigALiBaVa (IFX)run_029_IFX_CB_130V.dat029175000109, 4.5, 240NoUnknown

3Remarks: Telescope run 557. Bias scan 130 V.

Parameter Value
Alibava run run_029_IFX_CB_130V.dat
Telescope run 557
Triggers 175000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -130
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  74   Sat Apr 15 12:12:00 2017 Axel KoenigALiBaVa (IFX)run_030_IFX_CB_100V.dat0301000000109, 4.5, 240NoUnknown

3Remarks: Telescope run 558. Bias scan 100 V. Telescope chiller turned off. Could be the root cause of crashing runs.

Parameter Value
Alibava run run_030_IFX_CB_100V.dat
Telescope run 558
Triggers 1000000
Alibava trigger eff. ~60%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  71   Fri Apr 14 19:43:13 2017 Axel KoenigALiBaVa (IFX)run_027_IFX_CB_100V.dat027350000109, 4.5, 250NoUnknown

Remarks: Telescope run 550. Angle shift 250 deg.

Parameter Value
Alibava run run_027_IFX_CB_100V.dat
Telescope run 550
Triggers 350000
Alibava trigger eff. ~59.8%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 109 mm
Table z 4.5 mm
Tabe rot

250 deg

  5   Wed Apr 12 22:41:08 2017 Axel KönigALiBaVa (IFX)run_003_IFX_CB_100V.dat003100000109, 8.5, 240NoUnknown

Remarks: Beam position on only one chip.

Parameter Value
Alibava run run_003_IFX_CB_100V.dat
Telescope run 500
Triggers 100000
Alibava trigger eff ?
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100 V
Latency 132
Table x 109 mm
table z 8.5 mm
table rot 240 deg (parallel to tele. planes)
  123   Tue Apr 18 18:19:33 2017 Axel KoenigALiBaVa (IFX)run_001_double_irrad_100V.dat001350000111, 1, 240NoUnknown

Remarks: Telescope run 620. 2nd chip only. Central position.

Telescope chiller turned on!

Parameter Value
Alibava run run_001_double_irrad_100V.dat
Telescope run 620
Triggers 350000
Alibava trigger eff. ~53%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 111 mm
Table z 1 mm
Tabe rot

240 deg

  124   Tue Apr 18 18:48:27 2017 Axel KoenigALiBaVa (IFX)run_002_double_irrad_100V.dat00270000094, 1, 240NoUnknown

Remarks: Telescope run 623. 1nd chip only. Central position.

Telescope chiller turned on!

Parameter Value
Alibava run run_002_double_irrad_100V.dat
Telescope run 623
Triggers 700000
Alibava trigger eff. ~62%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 94 mm
Table z 1 mm
Tabe rot

240 deg

  140   Thu Apr 20 16:05:14 2017 Axel KoenigALiBaVa (IFX)run_013_Irrad_500V.dat01375000096, 54, 360NoUnknown

Remarks: Telescope run 643. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!

Positoj scan vertical.

Telescope chiller turned on (15 deg).

Parameter Value
Alibava run run_013_Irrad_500V.dat
Telescope run 643
Triggers 750000
Alibava trigger eff. ~70%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -500
Latency 132
Table x 96 mm
Table z 54 mm
Tabe rot

360 deg

Temperature at DUT -14.5 +- 1 deg. celsius
Current 39.2 uA
ELOG V3.1.5-fc6679b