Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 6 of 7  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Mon Apr 17 09:29:40 2017, Axel Koenig, ALiBaVa (IFX), run_018_Baby_90V.dat, 018, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 595. Bias scan 90 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 10:05:57 2017, Axel Koenig, ALiBaVa (IFX), run_019_Baby_110V.dat, 019, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 596. Bias scan 110 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 10:36:22 2017, Axel Koenig, ALiBaVa (IFX), run_020_Baby_120V.dat, 020, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 597. Bias scan 120 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 11:04:40 2017, Axel Koenig, ALiBaVa (IFX), run_021_Baby_130V.dat, 021, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 598. Bias scan 130 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 11:34:55 2017, Axel Koenig, ALiBaVa (IFX), run_022_Baby_140V.dat, 022, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 599. Bias scan 140 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 12:06:11 2017, Axel Koenig, ALiBaVa (IFX), run_023_Baby_150V.dat, 023, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 600. Bias scan 150 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 13:30:01 2017, Axel Koenig, ALiBaVa (IFX), run_001_HPK_CB_200V.dat, 001, 450000, 107, 0, 240, No, Unknown 
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 16:36:56 2017, Axel Koenig, ALiBaVa (IFX), run_002_HPK_CB_200V.dat, 002, 450000, 107, 5.8, 240, No, Unknown 
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 17:02:34 2017, Axel Koenig, ALiBaVa (IFX), run_003_HPK_CB_200V.dat, 003, 250000, 107, 2.6, 230, No, Unknown 
Remarks: Telescope run 606. Angle scan.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 17:46:38 2017, Axel Koenig, ALiBaVa (IFX), run_005_HPK_CB_50V.dat, 005, 150000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 609. Bias scan 50 V. Bias scan.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 19:19:14 2017, Axel Koenig, ALiBaVa (IFX), run_006_HPK_CB_100V.dat, 006, 150000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 610. Bias scan 100 V. Bias scan.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 19:54:08 2017, Axel Koenig, ALiBaVa (IFX), run_007_HPK_CB_150V.dat, 007, 300000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 611. Bias scan 150 V. Bias scan. Run crashed at 294000 triggers!

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 21:52:45 2017, Axel Koenig, ALiBaVa (IFX), run_008_HPK_CB_250V.dat, 008, 150000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 613. Bias scan 250 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Mon Apr 17 22:27:44 2017, Axel Koenig, ALiBaVa (IFX), run_009_HPK_CB_200V.dat, 009, 2400000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 614. Long run over night. run crashed over night!

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Tue Apr 18 08:04:39 2017, Axel Koenig, ALiBaVa (IFX), run_004_HPK_CB_200V.dat, 004, 250000, 107, 2.6, 250, No, Unknown 
Remarks: Telescope run 607. Angle scan.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Tue Apr 18 08:07:15 2017, Axel Koenig, ALiBaVa (IFX), run_010_HPK_CB_200V.dat, 010, 350000, 107, 2.6, 240, No, Unknown 
Remarks: Telescope run 616. Short run central position. Repeated due to crash over night.

No beam during run.Only ~10000 events.

Telescope chiller turned off (could be the root cause of runs crashing).
Entry  Tue Apr 18 18:19:33 2017, Axel Koenig, ALiBaVa (IFX), run_001_double_irrad_100V.dat, 001, 350000, 111, 1, 240, No, Unknown 
Remarks: Telescope run 620. 2nd chip only. Central position.

Telescope chiller turned on!




Parameter
Entry  Tue Apr 18 18:48:27 2017, Axel Koenig, ALiBaVa (IFX), run_002_double_irrad_100V.dat, 002, 700000, 94, 1, 240, No, Unknown 
Remarks: Telescope run 623. 1nd chip only. Central position.

Telescope chiller turned on!




Parameter
Entry  Tue Apr 18 21:03:42 2017, Axel Koenig, ALiBaVa (IFX), run_003_double_irrad_100V.dat, 003, 3500000, 103, 1, 240, No, Unknown 
Remarks: Telescope run 625. Both chips. Central position. Run crashed over night.

Collected triggers 2710991.

Telescope chiller turned on!
Entry  Wed Apr 19 17:31:43 2017, Axel Koenig, ALiBaVa (IFX), run_001_Irrad_100V.dat, 001, 400000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 628. Bias scan -100V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
ELOG V3.1.5-fc6679b